Download Print this page

Advertisement

Quick Links

MANUAL
Electronic circuit breaker
ECONOMY REMOTE
BLOCK Transformatoren-Elektronik GmbH
Max-Planck-Straße 36-46
27283 Verden
Germany
Phone +49 4231 678-0
Fax +49 4231 678-177
info@block.eu
block.eu

Advertisement

loading
Need help?

Need help?

Do you have a question about the ECONOMY REMOTE PC-3724-800-0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Block ECONOMY REMOTE PC-3724-800-0

  • Page 1 MANUAL Electronic circuit breaker ECONOMY REMOTE BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 Phone +49 4231 678-0 Fax +49 4231 678-177 • 27283 Verden Germany • info@block.eu block.eu •...
  • Page 2: Table Of Contents

    6.7.3 Max. Jitter for data transmission ....................14 6.8 Details on signal output S3 (∑ for triggered outputs and device fault) ....... 15 Dimensions ..................... 16 BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN Phone +49 4231 678-0 Fax +49 4231 678-177 •...
  • Page 3: Order Data

    24 Vdc 2 – 10A PM-3724-400-0 24 Vdc 2 – 10A PM-3724-200-0 24 Vdc 2 – 10A BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN Phone +49 4231 678-0 Fax +49 4231 678-177 • 27283 Verden Germany Subject to technical changes info@block.eu...
  • Page 4: General Information

    In the event of malfunctions or damage, switch off the supply voltage immediately and send the device to BLOCK Transformatoren-Elektronik GmbH for inspection. The device does not contain any service parts. If an internal fuse blows, there is most likely an internal defect in the appliance.
  • Page 5 CAUTION Do not touch the housing during operation or shortly after switching off. Hot surfaces can cause injuries. BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN Phone +49 4231 678-0 Fax +49 4231 678-177 •...
  • Page 6: Product Description

    Extended remote transmission of input voltage, set rated currents and current output currents Sum signalling contact for simple remote diagnostics Push-in direct connection technology LED signalling and on/off/reset button per channel BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN Phone +49 4231 678-0 Fax +49 4231 678-177 •...
  • Page 7: Tripping Characteristic

    89,5 83,3 58,1 156,1 94,8 68,1 >620 114,8 >620 >620 >620 >620 BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN Phone +49 4231 678-0 Fax +49 4231 678-177 • 27283 Verden Germany Subject to technical changes info@block.eu • block.eu •...
  • Page 8 All capacities were determined experimentally under nominal load. The tasks are guide values, possible line capacitances depend on the installation situation. The power supply unit must be able to supply the required current without the output voltage dropping below 18V. BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN...
  • Page 9: Operating States, Signalling, Reactions

    1. The next channel is switched on as soon as the output current of the previous channel is below the set nominal value or the previous output has been switched off, but not before 50 ms. BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN...
  • Page 10: On/Off And Reset" Button

    The signal output S3 serves as an active 24V collective fault signal and indicates that at least one output has been switched off due to overcurrent. An internal device fault is also signalled by S3. BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN...
  • Page 11: Functionality Of 2-Wire Communication Via S1/S2

    S2. (500 ms high pulse, every 3 seconds) This pulse is sent until the PLC has successfully queried the updated status via a new Manchester-coded telegram. BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN...
  • Page 12: Details On Signal Input S1 (Control And Reset)

    Coded pulse Trigger cur- pattern currents. See description of the pulse rents pattern below Adjustable in 6 levels BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN Phone +49 4231 678-0 Fax +49 4231 678-177 • 27283 Verden Germany Subject to technical changes info@block.eu...
  • Page 13: Description Of The Pulse Pattern

    If the PLC sends the coded pulse sequence via the signal input S1, the circuit breaker synchronises to the auxiliary clock of the PLC and sends the current on/off and error states via the signal output S2. Coding of the status bits sent by the circuit breaker BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN...
  • Page 14: Cyclical Pulse After Status Change, Generated By The Circuit Breaker

    S2 before starting to send the telegram or to generate a telegram at least every 3 se- conds to query the status. 6.7.3 Max. Jitter for data transmission The following absolute jitter is permitted depending on the selected clock cycle: BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN Phone +49 4231 678-0 Fax +49 4231 678-177 •...
  • Page 15: Details On Signal Output S3 (∑ For Triggered Outputs And Device Fault)

    "Active High" (+24V). As soon as at least one output channel has triggered or a device defect has been detected, or signal output switches to "Active Low" (0V). This signal output is short-circuit- proof and can be loaded up to max. 20mA. BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36-46 29.01.2025 / FRAN...