Advertisement

Quick Links

VH-0808ETN Module
Manual
V1.0
Archive date 2024-03-07
VEICHI Electric Co., Ltd. provides customers with all-round technical support. Please contact the nearest office or
service center, or directly contact the company headquarters.
Suzhou VEICHI Electric Co., Ltd.
All rights reserved. Contents are subject to change without prior notice.
Suzhou VEICHI Electric Co., Ltd.
Address: 3rd Floor, Building ChunSheng, Lingya Industrial Park, No. 1 Road, Tangtou Community, Shiyan Street,
Baoan District, Shenzhen, China
Hotline: 400-600-0303
Website: www.veichi.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VH-0808ETN and is the answer not in the manual?

Questions and answers

Summary of Contents for Veichi VH-0808ETN

  • Page 1 Manual V1.0 Archive date 2024-03-07 VEICHI Electric Co., Ltd. provides customers with all-round technical support. Please contact the nearest office or service center, or directly contact the company headquarters. Suzhou VEICHI Electric Co., Ltd. All rights reserved. Contents are subject to change without prior notice.
  • Page 2: Additional Materials

    Preface  Brief The VH-0808ETN series digital input/output expansion module features 8 channels of sink type digital input and 8 channels of NPN transistor digital output. It can be used in conjunction with the VH series main modules.  Additional Materials...
  • Page 3: Safety Statement

     Please use the product in an environment that meets the requirements of design specifications, otherwise it may cause failure, abnormal function or component damages, which is not within the scope of product quality assurance.  VEICHI will not take on any legal responsibility for personal safety accidents and property damage caused by unauthorized operation of the product.
  • Page 4: Operation And Maintenance

    Precautions VH-0808ETN Module Manual  As the PLC is an open type device, install it in a control cabinet (enclosure protection > IP20) with a lock, accessible only to operators trained in electrical equipment with sufficient electrical knowledge.  Avoid metal debris and wire ends falling into the PLC's ventilation openings during installation to prevent fire, malfunction, or misoperation;...
  • Page 5: Product Information

    VH – 08 08 E TN      Product information VH: VEICHI slim series IO module IO input points 08: 8 points IO output points 08: 8 points Module type E: Logic IO expansion module Output type...
  • Page 6 Product Information VH-0808ETN Module Manual 1.2 Component Interface Definition On (Green) Normal Power/Run Module abnormal (POWER+RUN) indicator Signal indicator Flash (Green) Module ready or stopped Error indicator On (Red) Module error Left side (00~07) indicators correspond to 8 input channels, lit when input is active;...
  • Page 7: Input Specification

    Product Information VH-0808ETN Module Manual Power isolation 24V and 5V isolated Terminal output power rated voltage None Terminal output power rated current None Module hot swap 1.3.2 Input Specification Item Specification Input type Digital input Input method Leakage Input channel Input voltage level 24VDC±10% (21.6VDC ~ 26.4VDC)
  • Page 8: Software Specification

    Product Information VH-0808ETN Module Manual 1.3.4 Software Specification Item Specification Software input filter time 0.25ms*N (N=0~255), with a common filter parameter for every group of 8 channels. Input port exception detection and None indication Input channel logic level Output status on fault...
  • Page 9: Mechanical Installation

    Mechanical Installation VH-0808ETN Module Manual 2 Mechanical Installation 2.1 Installation Dimension 2.1.1 Module Installation dimension information is shown in the following figure, and the unit is millimeter (mm): 14.5 85.4 Ensure at least 10mm of clearance above the product to accommodate the latch's movement.
  • Page 10 Mechanical Installation VH-0808ETN Module Manual The module is installed using the DIN lead rail. When installing, align the module to the DIN lead rail, press the module in the direction indicated by the arrow, and there will be an obvious clipping sound if it is in place, as shown in the figure below: Description: Depress the rail latch to open it, then place the module on the DIN lead rail and press down on the latch to secure it.
  • Page 11: Electrical Installation

    Electrical Installation VH-0808ETN Module Manual 3 Electrical Installation 3.1 Cable Selection In the following table, the lug diameter is for reference only, which can be calculated reasonably according to actual use and adjusted separately. Diameter Name GB/mm2 ANSI/AWG Tubular lug 0.75...
  • Page 12 Electrical Installation VH-0808ETN Module Manual Left Indicator Left Signal Left Terminal Right Terminal Right Signal Right Indicator 3.3 User Terminal Wiring 3.3.1 Input Terminal Wiring Note: The VH-0808ETN module is fixed with sink type input configuration.
  • Page 13: Output Terminal Wiring

    Electrical Installation VH-0808ETN Module Manual 3.3.2 Output Terminal Wiring...
  • Page 14: Module Programming

    Module Programming VH-0808ETN Module Manual 4 Module Programming 4.1 VEICHI CODESYS Programming Software 4.1.1 Create a New Project 4.1.2 Add a New Module Right-click it and select "Add Device."...
  • Page 15 Module Programming VH-0808ETN Module Manual Click the "Add Device."...
  • Page 16: Configure Parameters

    Module Programming VH-0808ETN Module Manual 4.1.3 Configure Parameters 4.1.4 Automatic Scanning The VH600 allows manual slot configuration or module scanning after installing the right expansion modules. The configuration and sequence of expansion modules must match the physical setup; otherwise, an alarm will warn of a mismatch between configuration and connection.
  • Page 17 Module Programming VH-0808ETN Module Manual 4.1.6 Set Parameters 4.1.7 Write User Program 4.1.8 Compile, Download, and Run If the compilation is without errors, download and run the program.