When preparing the installation site please take into consideration that this equipment is for restricted access locations only! Please download the Service and User's manuals from G&J home page www.glunz-jensen.com before the installation of the processor. 1136 Pre-installation Manual - Plate Processors 68/85...
The operator must observe and/or act according to the information in order to avoid any mechanical or electrical Caution damage to the equipment. The operator must observe and/or act according to the information in order to avoid any personnel injury. Warning Pre-installation Manual - Plate Processors 68/85 1136...
The icons on the crate indicate how to handle the crate during transport and storage: Ensure that the side Handle the crate Never expose the indicated by the with care. crate to water, or arrows is always place it in a high-humidity area. Pre-installation Manual - Plate Processors 68/85 0835...
The Service Technician has to unpack the > 1170 mm (46.1") > 1170 mm (46.1") processor. < 1100 mm (43.3") < 1250 mm (49.2") The Service Technician has to unpack and strip down the processor. 0835 Pre-installation Manual - Plate Processors 68/85...
It is essential to have easy access to a sink and a water tap with hot water where rollers, guides, and brushes can be washed. Minimum recommended size of the sink 90 x 40 cm (35.4 x 15.7") 100 x 40 cm (39.4 x 15.7") 0835 Pre-installation Manual - Plate Processors 68/85...
> 100 cm (39.4") > 50 cm (19.7") Processor filter unit > 100 cm (39.4") T31496 " For CTP On-line processors the space requirements at the processor front has to be decided separately. Pre-installation Manual - Plate Processors 68/85 0835...
The supply water pressure must be min. 2 - 6 bar (29 - 87 psi). Drains Many countries have strong regulations regarding disposal of waste. Refer to the local regulations when making preparations for drains. Pre-installation Manual - Plate Processors 68/85 0835...
Provide for additional cable protection, e.g. cable covers, if cable is exposed to heavier transport such as fork-lift trucks etc. The processor is Class 1 equipment. Therefore, the processor must be connected to earth to avoid electrical shocks. Please be aware of double pole/neutral fusing. 0835 Pre-installation Manual - Plate Processors 68/85...
If using automatic circuit breakers make sure that they are Type D. Power consumption Max. power consumption at … 230/400 VAC operation: • • 3100 Watt / approx. 10600 BTU/hour EUR/ Stand-by: • • 750 Watt / approx. 2560 BTU/hour Pre-installation Manual - Plate Processors 68/85 1140...
(cables, fuses, etc.) necessary to connect the processor to the mains? D. Is there a house electrician available? E. Are there any known problems in the building where the processor will be installed? If so, explain: ....................................................................................................................................................0835 Pre-installation Manual - Plate Processors 68/85...
Page 20
F. Does the supply water pressure lie between 2 and 6 bar (29 and 87 psi)? G. Availability of warm water for cleaning of processor? 4. Disposition of the various supplies and equipment on the installation site: Pre-installation Manual - Plate Processors 68/85 0835...