Novega PT9 NINETY User Manual

Underwater locating device (uld)

Advertisement

Quick Links

Document number MA_Ninety_UserManual_Rev_6.0
Novega Produktionssysteme GmbH
Gewerbepark 2 | 87477 Sulzberg (See) | Germany
Fon: +49/8376/92990-0 | Fax: +49/8376/92990-20
info@novega.de
|
www.novega-sea .com
PNR:
PNR Revision:
Cage Code:
PT9_NINETY
00
CG871
Issue No.: 6
Amendment No.: 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PT9 NINETY and is the answer not in the manual?

Questions and answers

Summary of Contents for Novega PT9 NINETY

  • Page 1 Document number MA_Ninety_UserManual_Rev_6.0 Novega Produktionssysteme GmbH Gewerbepark 2 | 87477 Sulzberg (See) | Germany Fon: +49/8376/92990-0 | Fax: +49/8376/92990-20 info@novega.de www.novega-sea .com PNR: PT9_NINETY PNR Revision: Cage Code: CG871 Issue No.: 6 Amendment No.: 0...
  • Page 2: Table 1-1: Authorizations Table

    2021.09.01 15:01:18 +02'00' This document/data is the property of Novega. You may not possess, use, copy, or disclose this document/data or any information contained therein, for any purpose, including without limitation to design, manufacture, or repair parts, or obtain BSH or any other government approval to do so, without Novega express written permission. Neither receipt nor possession, use, copying, or disclosing by anyone without Novega express written permission is not authorized and may result in criminal and/or civil liability.
  • Page 3: Table Of Contents

    Mounting ........................14 Operational and Battery Testing with Ulyser ................15 General ..........................15 Cleaning ..........................15 Testing with the Novega Ulyser ..................... 15 Testing with TAG 2550 Tester ....................... 16 Service Operation Mode ....................... 16 Battery Voltage Measurement ....................17 Acoustic Test..........................
  • Page 4 13 End of Service Life ......................... 25 14 Returns ............................25 14.1 Service Address ........................25 15 Warranty and Guaranty ......................... 25 16 CE-Conformity ..........................25 Issue No. 6 Amendment No. 0 Page 4 of 25 © Novega 2021, confidential and proprietary document...
  • Page 5 Ninety User Manual Document Name: MA_Ninety_UserManual List of Figures Figure 1: PT9 NINETY ..........................8 Figure 2: Type Plate Example ........................9 Figure 3: ULD Dimensions ........................10 Figure 4: Ulyser ............................15 Figure 5: Service Operation Mode ......................16 Figure 6: Battery Voltage Measurement ....................
  • Page 6: Ma_Ninety_Usermanual

    This manual contains the description, as well as the installation and maintenance directions for the PT9 NINETY Underwater Locating Device. The nautical equipment Underwater Locating Device (ULD) / PT9 Ninety have been type examination tested and meet or exceed all applicable requirements of the SAE AS8045A:2011 and IEC 61996, Ed.2:2013 (Voyage Date Recorder).
  • Page 7: Definitions

    BSH ..............Federal Office for maritime navigation and hydrography PNR ........................Equipment Part Number SAE AS8045A ......... Minimum Performance Standard for Underwater Locating Devices Issue No. 6 Amendment No. 0 Page 7 of 25 © Novega 2021, confidential and proprietary document...
  • Page 8: General

    3 General 3.1 Description The PT9 NINETY Underwater Locating Device (ULD) is battery-powered and primarily consists of an electronic module and a signal transmitter. Protected by a cylindrical, water- and weatherproof hous- ing, the ULD withstands extreme environmental conditions, high G-impact shock and deep sea - pres- sure up to 6096 m.
  • Page 9: Type Plate Example

    Three years after this date, the lifetime of the beacon expires. Issue No. 6 Amendment No. 0 Page 9 of 25 © Novega 2021, confidential and proprietary document...
  • Page 10: Specification

    Length: see Figure 3: ULD Dimensions Diameter: Weight: 187 g (6.6 oz) Table 3-1: Specification : center of gravity Figure 3: ULD Dimensions Issue No. 6 Amendment No. 0 Page 10 of 25 © Novega 2021, confidential and proprietary document...
  • Page 11: Sae As8045A Testing Qualification Summary

    70 N/m2 (700 dyne/cm2) r.m.s. pressure normalized at 1 metre range, that 90 Days Continuous SAE AS8045A § 4.8.2 is, at a level of 157 dB vs 1 μPa at 1 metre Operation Issue No. 6 Amendment No. 0 Page 11 of 25 © Novega 2021, confidential and proprietary document...
  • Page 12: Occurrence Report

    6.1 - 6.4 the ULD shall meet all the requirements of Section 4 Verification Table 3-2: Test Qualification Summary Equipment 3.5 Occurrence Report For reporting of any occurrence related to a Novega authorised equipment, the following mail-ad- dress info@novega.de shall be used.
  • Page 13: Installation

    Additional unapproved stamps or labels on the ULD may reduce the acoustic radiation. Note: In case of doubt, or if the ULD should show damages, please contact our service department (Service Address). Issue No. 6 Amendment No. 0 Page 13 of 25 © Novega 2021, confidential and proprietary document...
  • Page 14: Mounting

    Pt9 Ninety. Minor damages on the surface coating must be repaired immediately to avoid corro- sion and negative effects on the durability of the PT9 Ninety. Use of a Novega accredited protective paint is recommended. Improper handling causes guarantee loss.
  • Page 15: Operational And Battery Testing With Ulyser

    The water switch pins are to be cleaned whenever dirt or dust accumulate. 5.3 Testing with the Novega Ulyser The Ulyser is the state-of-the-art device to test and analyze all Novega ULD´s. All necessary tasks are performed quickly and easily. The Ulyser is a battery-powered receiver for ultrasonic signals with a frequency of 5 to 50 kHz.
  • Page 16: Testing With Tag 2550 Tester

    For a complete functional test, the TAG 2550 Tester and a high impedance multimeter is required. • Use the Novega TAG 2550 Tester for the acoustic signal test. Please consider, that therefore the ULD has to be set into service operation mode (see 6.1).
  • Page 17: Battery Voltage Measurement

    If battery voltage is in order but no signal is received, please read the fault isolation instructions (see 7) or contact our service department (Service Address). Issue No. 6 Amendment No. 0 Page 17 of 25 © Novega 2021, confidential and proprietary document...
  • Page 18: Fault Isolation

    The ULD is not in "Service Opera- Switch the ULD in the "Service Op- tion Mode". eration Mode", refer to Service Operation Mode. Issue No. 6 Amendment No. 0 Page 18 of 25 © Novega 2021, confidential and proprietary document...
  • Page 19: Table 7-1: Fault Isolation

    Figure 2: Type Plate readable, please contact our Example. Service Address for further assis- tance. Table 7-1: Fault Isolation Issue No. 6 Amendment No. 0 Page 19 of 25 © Novega 2021, confidential and proprietary document...
  • Page 20: Battery Replacement

    ULD into the Service Operation Mode or a failure of the battery (not anticipated). In both events, do not open the ULD as it might be under pressure! Please contact our service department ) for further assistance. Service Address Issue No. 6 Amendment No. 0 Page 20 of 25 © Novega 2021, confidential and proprietary document...
  • Page 21: Ma_Ninety_Usermanual

    When the expiry date is reached, the battery should be disposed of in accordance with all local, state and federal regulations. Figure 8: Remove the Battery Issue No. 6 Amendment No. 0 Page 21 of 25 © Novega 2021, confidential and proprietary document...
  • Page 22 (see figure 2 in chapter 3.2). l) Mounting of the ULD Mount the ULD in the order described under chapter 4.2.2. Issue No. 6 Amendment No. 0 Page 22 of 25 © Novega 2021, confidential and proprietary document...
  • Page 23: Long-Term Storage

    Please note that differences of the housing and the battery cap in terms of colour are coating specific and do not lead to any loss of corrosion resistance. Issue No. 6 Amendment No. 0 Page 23 of 25 © Novega 2021, confidential and proprietary document...
  • Page 24: Illustrated Parts List

    Part number Quantity Underwater Locating Device PT9_NINETY Housing 23708-00 Battery 18725-00 Battery Cap 18724-00 Table 12-1: Illustrated Parts List Figure 9: Illustrated Parts Issue No. 6 Amendment No. 0 Page 24 of 25 © Novega 2021, confidential and proprietary document...
  • Page 25: End Of Service Life

    For further information regarding warranty and guaranty, please contact our service department (Ser- vice Address). 16 CE-Conformity This ULD meets the requirements of the EU-Directives for CE marking. Issue No. 6 Amendment No. 0 Page 25 of 25 © Novega 2021, confidential and proprietary document...