Service and repair should only be performed by STANDARD * qualified technicians who have read and Model Elements Current Power Length Amps 230V understand this manual. HE900 900W Personnel must be trained prior to operating HE1200 1200W 1200 this appliance. HE1500 1500W 1500 HE1800...
These units are designed to be mounted above This machine contains no user-serviceable parts. food serving and preparation areas to provide Roband Australia, one of our agents, or a HEAT without illumination. similarly qualified person(s) should carry out We recommend mounting heights between repairs.
STEP 1, INSTALLATION - ELEMENTS Hold the heat lamp in the position where it is to be ELEMENT REPLACEMENT mounted, mark the In the rare case of the element failing, it should position of the mounting be replaced by a qualified person such as an plates electrician.
TROUBLESHOOTING Parts for HE If the Heating Assembly does not function check HE900 the following points before calling for service. HC0170 Element - 900W 230V ✓ The device is plugged in correctly and the power switched on. HE1200 ✓ The power point is not faulty.
CIRCUIT DIAGRAM HUE SERIES HE SERIES NOTE: This circuit diagram has been provided for reference and to assist qualified service and repair agents only. Under no circumstances should person’s not suitably qualified attempt repairs to any electrical equipment...
Tubular Heating Elements is not a warranty fault. Roband or any subsidiary company or Agent shall not be liable for loss of profit or damage to other equipment and property except where it is in breach of the guarantees provided in accordance with applicable legislation.