Download Print this page
Stocks AG Maxi Meter Original Operating Manual And Parts List

Stocks AG Maxi Meter Original Operating Manual And Parts List

Hide thumbs Also See for Maxi Meter:

Advertisement

Quick Links

Revision 3, 03/2023
Revision 3
05/06/23
Maxi Meter
Maxi Meter Operating Manual & Parts List P

Advertisement

loading
Need help?

Need help?

Do you have a question about the Maxi Meter and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stocks AG Maxi Meter

  • Page 1: Maxi Meter Parts List

    Revision 3, 03/2023 Revision 3 05/06/23 Maxi Meter Maxi Meter Operating Manual & Parts List P...
  • Page 2: Table Of Contents

    Control System 10.2 Electrical Connections 10.3 i-CON Instrument Functions 10.4 Precision Farming Software 10.5 i-CON Calibration 10.6 At the Machine 10.7 At the i-CON Instrument 10.8 Manual Calibration 10.9 GPS Speed Maxi Meter Operating Manual & Parts List P2...
  • Page 3 Feed Roller Adjustment 11.2 Feed Adjuster Assembly 12.0 Add On Unit 12.1 Spreader Plates 13.0 Maxi Meter Parts Drawing 13.1 Maxi Meter Parts List Page 1 13.2 Maxi Meter Parts List Page 2 Maxi Meter Operating Manual & Parts List P3...
  • Page 4: Declaration Of Conformity

    Maxi Meter Operating Manual & Parts List P4...
  • Page 5: Ukca. Declaration Of Conformity

    Maxi Meter Operating Manual & Parts List P5...
  • Page 6: General Information

    This machine is not designed to apply small seeds such as clover and OSR, abrasive materials such as sand & grit, or salt products. Machines are not designed to be tipped when in work. The operator alone bears the associated risk if used for non-intended use. Maxi Meter Operating Manual & Parts List P6...
  • Page 7: Machine Identification

    If the base machine or the controls system are modified in any way this will void any warranty claim. Please see our conditions of sale for full details, a copy of which available upon request. Please record the machine serial number here: ……………………………… Purchase date: …………………………………………… Dealer …………………………… Maxi Meter Operating Manual & Parts List P7...
  • Page 8: Safety

    If in doubt contact the vehicle manufacturer for more information. After working the machine ensure that any unused product is returned safely to its original packaging. Stocks Ag Ltd. does not accept any liability for the storage and use of the material being applied.
  • Page 9: Safety Warning Decals

    Keep Clear! Maintain a safe distance from the machine when in operation. Wear the appropriate protective personal equipment. WARNING! Do Not Jet Wash This machine is not designed to withstand Jet Washing. Maxi Meter Operating Manual & Parts List P9...
  • Page 10: Emergency Stop Instructions

    Always adhere to the local disposal regulations paying particular attention to the plastics, rubber, and electrical components. Maxi Meter Operating Manual & Parts List P10...
  • Page 11: General Maintenance

    2. Disconnect the power supply. 3. Replace the PVC waterproof cover (if applicable). 4. Store in dry conditions to protect the machine and control system from moisture. WARNING DO NOT JET WASH THIS MACHINE. Maxi Meter Operating Manual & Parts List P11...
  • Page 12: Machine Mounting

    It is not practical to supply tailored mounting brackets for every implement on the market, and so the final attachment of the Maxi Meter to the implement is the responsibility of the supplying dealer or end user. Select a strong, rigid position to bolt to the hopper units to your implement or parent vehicle. Fabricate and fit a work platform and steps, complete with handrails if necessary ensuring there is sufficient room to access the hopper.
  • Page 13: Vari-Speed Controls

    (-) terminal. NOTE: Always replace any blown fuse with the same amp rated blade type fuse as the original one fitted. Control extension cables available. If required please contact your local Stocks Ag dealer. WARNING! Failure to connect to the vehicle battery may result in control function problems and possible damage to the vehicle battery and charging system must be in good condition to achieve the best results.
  • Page 14: Control Panel

    NOTE: Heavy Duty Cut Out Switch available: For more information please consult your local Stocks Ag dealer WARNING! Ensure the position and operation of the control panel does not affect the visibility of the operator or the ability to control the parent machine.
  • Page 15: Product Calibration

    It is the responsibility of the operator to ensure safe handling of the machine and the appropriate personal protection equipment is worn for the material being applied and to prevent contamination to the machine or the environment. Maxi Meter Operating Manual & Parts List P15...
  • Page 16: I-Con Controls

    Any modification to the wiring, fuse holder or controls will invalidate any warranty claim and may affect the performance. Always replace any blown fuse with the same rated fuse as the original one fitted. Maxi Meter Operating Manual & Parts List P16...
  • Page 17: I-Con Instrument Functions

    The instrument can be unlocked to activate the precision farming program as a cost option. This is something that can be requested when the machine is purchased or can be added at a later date. Please contact your local Stocks AG dealer for more details. Maxi Meter Operating Manual & Parts List P17...
  • Page 18: I-Con Calibration

    NOTE: Recommended min speed 0.8kph - 1.2kph (if not see feed roller configuration). 17. Touch to save the new factor, it is advised to repeat the calibra- tion two more times to ensure accuracy. Maxi Meter Operating Manual & Parts List P18...
  • Page 19: Manual Calibration

    If the indicated speed range does not work for your operation, you must change the feed roll configuration or the type of feed roll to apply more or less seed, per revolution of the feed mechanism, as required. Once completed, recalibrate and note the new speed range. Maxi Meter Operating Manual & Parts List P19...
  • Page 20: Feed Shaft Speed

    NOTE: When the adjuster reaches the end of its travel and begins to tighten back off one full turn and lock into position. WARNING! Always observe all application standards and guidelines provided by the product manufacturer as some products may be toxic. If unsure contact your supplier for more information. Maxi Meter Operating Manual & Parts List P20...
  • Page 21: Add On Unit

    To double the number of outlets available Add On Units are available. An Add On Unit needs to be mounted to one side of the Maxi Meter Drive Unit and the feed shafts joined. The Feed Adjuster Assembly then removed and fitted to the Add On unit.
  • Page 22: Maxi Meter Parts Drawing

    13.0 Maxi Meter Parts Drawing Maxi Meter Operating Manual & Parts List P22...
  • Page 23 M10 –022 M10 Nylock Nut M12-008 M12 Flat Washer M12-002 M12x25 Hex Head Setscrew M12-014 M12 Nyloc Nut M8-001 M8x16 Hex Head Setscrew M6-005 M6x20 Hex Head Setscrew FJ008A M6x6 Grub Screw Maxi Meter Operating Manual & Parts List P23...
  • Page 24 Junction Box TJ251A i-CON Hopper Level Sensor MM107C 7m Fused Battery Connector Cable Not Shown TJ252 Automatic Cut-out Switch TJ253 Switch Mounting plate TJ255B GPS Receiver TJ235 Instrument Mount Not Shown Maxi Meter Operating Manual & Parts List P24...
  • Page 25 Notes Maxi Meter Operating Manual & Parts List P25...