Installation diagram model 30kg 6GN 1/1 367/8 " 936 mm 35/8 " 331/4 " 355/16 " 92 mm 844 mm 897 mm 23/8 " 60 mm 2711/16 " 703 mm 20 " 508 mm 191/2 " 495 mm 215/16 " 241/4 "...
Page 3
Installation diagram model 50kg 10GN 1/1 3615/16 " 938 mm 35/8 " 335/16 " 351/4 " 92 mm 846 mm 895 mm 23/8 " 60 mm 273/4 " 705 mm 20 " 508 mm 191/2 " 495 mm 3 " 241/4 "...
Page 4
Installation diagram model 70kg 10GN 2/1 4215/16 " 1091 mm 493/16 " 35/8 " 395/16 " 1250 mm 92 mm 999 mm 215/16 " 74 mm 331/4 " 844 mm 263/4 " 197/8 " 680 mm 506 mm 33/4 " 285/8 "...
Page 5
Installation diagram model 100kg 20GN 1/1 4015/16 " 1040 mm 337/16 " 850 mm 301/8 " 765 mm 273/4 " 704 mm 29/16 " 65 mm 187/8 " 480 mm OUTLET EXT Ø16mm INLET EXT Ø9,5mm 39/16 " 151/4 " 17/16 "...
Page 6
Installation diagram model 200kg 20GN 2/1 551/8 " 1400 mm 497/8 " 1266 mm 477/16 " 1205 mm 3011/16 " 780 mm 36 " 915 mm 1011/16 " 351/4 " 271 mm 896 mm 711/16 " 111/16 " 196 mm 43 mm 315/16 "...
Page 7
Installation diagram model 200kg 20GN 2/1 pass-through 551/8 " 1400 mm 5415/16 " 1395 mm 501/16 " 1272 mm 3011/16 " 36 " 780 mm 915 mm 1011/16 " 351/4 " 271 mm 896 mm 711/16 " 111/16 " 196 mm 43 mm 315/16 "...
Page 8
Installation diagram model 200kg 20GN 2/1 with ramp 551/8 " 1400 mm 497/8 " 1266 mm 477/16 " 1205 mm 3011/16 " 780 mm 36 " 915 mm 1011/16 " 271 mm 351/4 " 2215/16 " 896 mm 583 mm 689/16 "...
Page 9
EI = Power cable length RO = Refrigerant outlet (gas) WIC = Cooling water inlet D = Compartment drain hole WOC = Cooling water outlet Q = Lifting hooks RI = Refrigerant inlet (liquid) U = USB...
Page 10
Foreword Read the following instructions, including the warranty terms before installing and using the appliance. Visit our website www.electroluxprofessional.com and open the Support section to: Register your product Get hints & tips of your product, service and repair information The installation, use and maintenance manual (hereinafter Manual) provides the user with information necessary for correct and safe use of the appliance.
Contents A WARNING AND SAFETY INFORMATION....................12 General information ........................12 Description of type reference......................12 Personal protection equipment ...................... 13 General safety ........................... 13 Climatic Class..........................14 Total appliances weight ........................ 14 Transport, handling and storage ....................14 Installation and assembly ......................14 Electrical connection ........................
WARNING AND SAFETY INFORMATION General information To ensure safe use of the appliance and a proper understanding of the manual it is necessary to be familiar with the terms and typographical conventions used in the documentation. The following symbols are used in the manual to indicate and identify the various types of hazards: WARNING Danger for the health and safety of operators.
Personal protection equipment Summary table of the Personal Protection Equipment (PPE) to be used during the various stages of the appliance's service life. Stage Protective Safety footwear Gloves Glasses Safety helmet garments ● ○ ○ — — Transport ● ○ —...
– Dismantling operations of appliances which use flammable insulation blowing gases; Climatic Class The climatic class given on the data plate refers to the following values: • CLIMATIC CLASS: 5 – 43℃ (IEC/EN 60335-2-89) – 40℃ room with 40% relative humidity (IEC/EN ISO 23953). Total appliances weight Appliance Weight Models...
Refrigerante / Refrigerant xxxxx Illuminazione / Lighting Cap. Cyclopentane expanding gas used in insulation power supply voltage IPxx Electrolux Professional SPA - Viale Treviso, 15 - 33170 Pordenone (Italy) power supply frequency power input present only in appliances with three-phase power supply...
Refer to “Warning and Safety This manual is intended solely for consultation by the operator and can only be given to third parties with the permission of Information“. Electrolux Professional SpA. Introduction Keeping the manual This manual contains information relevant to various applian- The manual must be carefully kept for the entire life of the ces.
• unforeseeable extraordinary events; port personnel. • use of the appliance by uninformed and / or untrained Manufacturer Electrolux Professional SpA or any other personnel; service centre authorised by Electrolux • non-application of the current provisions in the country of Professional SpA.
1. Remove the condenser panel; Polyethylene • Outer wrapping • Instructions bag Polypropylene • Straps Polystyrene foam • Corner protectors The parts in wood and cardboard can be disposed of, respecting the current regulations in the country where the appliance is used. 2.
10GN 2/1 model F.5.4 Condensate tray positioning CAUTION Install the condensate tray after the appli- ance positioning and levelling: do not use fork lifts when the condensate tray run- ners are mounted. 6GN 1/1 – 10GN 1/1 – 10GN 2/1 models: •...
F.5.6 Positioning the top If the 6 GN 1/1 model is arranged for the “Cook&Chill“ column, but is not installed on the column, order the top kit. For the installation follow the instructions included in the kit. F.5.7 Draining water •...
NOTE! Make sure the liquid collection tray has been emptied before opening the plug to drain compart- ment washing liquids. From A to B: 1,5 meter (5 feet) minimum. NOTE! Before opening the plug to drain compartment washing liquids, make sure the appliance has been connected to a water drain trap system or that the IMPORTANT tray has been emptied.
NOTE! The tray supports are removable. It is possible to adjust their distance as necessary. 20GN 2/1 models F.6.1 Positioning NOTE! It is advisable to remove the appliance from the pallet using the eyebolts on the top. If this is not possible, proceed as follows: •...
• slide the equipment in, taking care not to damage the • Installation with foam bottom and ramp: bottom; Arrange the blast chiller in the required place, making sure to allow enough space for the ramp for accessing the compartment. When positioning refer to paragraph “Appliance space limits“.
For the connection proceed as follow: F.6.4 Inserting the trolley tray rack in appliances WARNING In appliances with ramp, handle the trolley tray rack carefully, to avoid its overturning and the spilling of liquids. CAUTION The trolley tray rack is supplied with a removable handle.
APPLIANCE SETUP – WIZARD IMPORTANT Introduction • This setup is meant to be carried out ONLY by a When the appliance is switched on for the first time, an specialised personnel. automatic procedure(Wizard), checks if all the parameters are • Always refer to the “service manual“ to change or properly set.