Advertisement

Homedics 1714078 Manual

OVERVIEW

OVERVIEW

HOW TO USE

DIGITAL DISPLAY AND REMOTE CONTROL

HOW TO USE - DIGITAL DISPLAY AND REMOTE CONTROL

CONTROL PANEL

HOW TO USE - CONTROL PANEL

HOW TO FILL


Before filling the tank with water, turn the power off and unplug the humidifier from the outlet.

information NOTE: Always use 2 hands to carry the water tank. The convenient top-fill tank can be filled with a pitcher or at the faucet. For best results, use distilled water.

HOW AND WHY TO USE DEMINERALIZATION CARTRIDGES
The Homedics demineralization cartridge will help reduce the potential for white dust, a deposit of minerals left behind from using hard water in your humidifier. The cartridge should be replaced every 30–40 fillings. The cartridge may need to be replaced more often if you are using very hard water.

TO FILL WITH A PITCHER

  1. Remove 1 demineralization cartridge from packaging and soak in water for 10 minutes.
  1. Remove the tank cover to fill the tank.
  1. Fill with clean, cool water or distilled water (if in area with hard water) until the water level reaches the MAX fill line. DO NOT fill with warm or hot water.


    Never add essential oils or other additives to the water tank or water reservoir.
  1. Add the soaked demineralization cartridge to the water tank.
  1. Replace the top cover.

TO FILL AT THE FAUCET

  1. Remove 1 demineralization cartridge from packaging and soak in water for 10 minutes.
  1. To fill at the faucet, remove the tank cover and remove the water tank.
  1. Use 2 hands to carry the water tank. Fill with clean, cool water or distilled water (if in area with hard water) until the water level reaches the MAX fill line. DO NOT fill with warm or hot water.
    TO FILL AT THE FAUCET

    Never add essential oils or other additives to the water tank or water reservoir.
  1. Add the soaked demineralization cartridge to the water tank.
  1. Reassemble making sure all parts are firmly seated.

ABOUT WHITE DUST
Use of high mineral content hard water may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. The mineral residue is commonly called "white dust." The higher the mineral content (or, the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier. It is caused only by minerals suspended in the water.

HOW TO OPERATE

POWER BUTTON

Turns humidifier on/off.

WARM MIST

Press to turn warm mist on/off. The warm mist icon will illuminate on the display. Once warm mist is selected, it will take 20-30 minutes to warm the mist.

TIMER

Press the timer button until the desired auto-shutoff timer setting is displayed. The timer button will cycle through the following settings: 2, 4, 8, 12, and 0 hours. To cancel the timer at any time, press the timer button until 0 hours is displayed.
information NOTE: Always be sure the humidifier has a full tank of water prior to using the timer setting.

NIGHT-LIGHT/DISPLAY LIGHTS

Press the night-light button once to turn on the night-light. The light at the bottom of the humidifier will turn on. Press the button a second time to leave the night-light on, but turn off display panel. Press the button a third time to turn off the night-light and display panel. Press the night-light button a fourth time to turn the display lights on.

PROGRAMMING THE HUMIDITY LEVEL

The default humidistat setting is CO (continuous on). The programmable humidistat can be set in 5% increments, from 35% to 55% humidity or continuous on. The humidity level will increase by 5% each time the button is pressed and will be displayed on screen.
information NOTE: Humidifier will turn off when the set humidity level is reached. Humidifier will turn on when the humidity level drops 5% below the set humidity level.
information NOTE: To eliminate any programmed humidistat setting, continue to press the programmable humidistat button until you reach CO, one level after 55%.

MIST OUTPUT

Mist adjusts from the lowest output (1) to the highest output (5). To increase the mist output, press the mist output button. The corresponding mist level will be lit on the display. Use the 360-degree rotating mist nozzle to adjust the mist output direction. Do not point the mist nozzles toward walls or furniture.

AUTO MODE

Automatically adjusts mist output based on room humidity. Press to turn auto mode on/off. When on, AU will show on the digital display.

  • Less than 35% RH, the humidifier will operate at mist level 5. The color code will glow red.
  • Between 35%-55% RH the humidifier will operate at mist level 3. The color code will glow green.
  • Over 55% RH the humidifier will cycle off until the humidity level drops below 55% RH. The color code will glow green.

HOW TO USE OIL TRAY


Putting oil anywhere but the oil tray will damage the humidifier.

  1. The oil tray is located on the back side of the humidifier at the bottom of the humidifier base.
  1. Push to open and remove the tray. Use the 1 pre-installed essential oil pad in the oil tray (3 total included).
    HOW TO USE OIL TRAY
  1. Add 5–7 drops of essential oil to the pad. You may use more or less depending on personal preference.


    Only place essential oil on the pad and NOT directly into the tray.
  1. Place the oil tray back in its compartment and push to close. The scent will start automatically when the mist is turned on.

information NOTE: For use with the included Homedics essential oil pads only.

information NOTE: Do not leave a used essential oil pad in the oil tray if it will be out of use for a long period of time.

ARE ESSENTIAL OILS SAFE TO USE AROUND PETS?
We should always exercise caution when using essential oils around pets. Keep all essential oil and aromatherapy products (like diffusers) out of the reach of pets. Keep open bottles away from pets to avoid internal consumption. We do not recommend the topical use of essential oils on pets, as they have a strong sense of smell and cannot get rid of the oil if they don't like it or it is disturbing them. When diffusing essential oils around pets, always diffuse in a wellventilated area and leave an option for them to remove themselves from the space, such as leaving a door open. Every animal is different, so carefully observe how each animal responds when introducing an essential oil for the first time. If irritation occurs, discontinue the use of the essential oil. We recommend seeking medical attention if ingestion of essential oil occurs.

HOW TO CLEAN AND CARE


Before cleaning, turn off and unplug the humidifier. Clean over a waterproof surface near a faucet.
DO NOT place any parts of the humidifier in the dishwasher.
DO NOT submerge the humidifier base in water or any other liquid. Doing so will damage the humidifier.
DO NOT use abrasive pads or brushes, harsh chemicals, detergents, or liquid soaps to clean the humidifier. Clean with a soft cloth, cotton swab, or soft brush.

WEEKLY CLEANING

  1. Remove the tank cover and mist nozzle.
  1. Remove the water tank and pour out any water from the tank and water reservoir.
  1. Rinse the tank cover, mist nozzle, and water tank with room temperature water.
  1. Wipe inside the mist tube with a damp soft cloth or soft brush.
  1. Fill the water reservoir halfway with water, swish, and pour out.


    Never submerge the base in water on any other liquid.
  1. Thoroughly dry all parts with a soft cloth and reassemble.

SCALE REMOVAL

Perform when the Clean Reminder glows red, before storage, or as needed. Failure to do so may cause reduced or no mist output. Prepare 4 cups/ 950 mL of a cleaning solution using a 50/50 mix of white vinegar and water.

  1. Remove the tank cover and pour out any water from the tank and water reservoir.
  1. Fill the tank with 4-cups/950 mL of 50/50 white vinegar and water. Swish the solution around the water tank. Do not pour out the solution.
  1. Place the tank on the base. The solution will drain into the water reservoir and loosen scale/water mineral build-up.
  1. Soak for 15-20 minutes.
  1. Pour out the solution from the water tank and water reservoir. Rinse the water tank with clean water until the vinegar smell is gone and wipe dry with a soft cloth.
  1. Remove the mist nozzle. Clean using the solution on a cotton swab. Rinse with water to remove the vinegar smell, dry and set aside.
  1. Add a small amount of solution to a soft cloth or soft brush to clean inside the mist tube. Wipe with a damp, soft cloth, or soft brush to remove the vinegar smell. Do not pour water into the mist tube.
  1. Wipe the transducer/ ultrasonic membrane with a cotton swab to remove loosened scale. Wipe off with a damp cotton swab. Never touch the transducer/ ultrasonic membrane with your fingers; the natural oils in the skin can damage the surface. Brush the hinge to remove any water minerals.
  1. Pour a small amount of water in the water reservoir, swish, and pour out. Repeat until the vinegar smell is gone.


    Never submerge the base in water on any other liquid.
  1. Completely dry all parts with a soft cloth before reassembling or storage.

CLEANING THE OIL TRAY

  1. Open the oil tray and remove the pad.
  2. Rinse the oil tray with water and wipe dry with a soft cloth. DO NOT clean with detergent or liquid cleaners.

information NOTE: If continuing to use the same scent, set the oil pad aside for reuse. DO NOT leave a used pad in the oil tray when storing.

STORAGE

Store in a cool, dry location.

Before storing

  1. Descale the humidifier following the Scale Removal instructions.
  2. Clean the oil tray following the Cleaning The Oil Tray instructions. DO NOT leave a used pad in the oil tray when storing.

After storing

  1. Rinse the tank with water prior to operating.

REMOTE CONTROL BATTERY REPLACEMENT

  1. Use a small Phillips-head screwdriver to unscrew the battery compartment screw.

    information NOTE: The screw is not removable.
  1. Remove the battery cover.
  1. Remove the button cell battery and dispose of per local regulations.
  1. Install a new CR-2025 button cell battery following the polarity as shown.
  1. Replace the battery cover and screw closed.


KEEP BATTERIES OUT OF REACH OF CHILDERN.

  1. Swallowing may lead to serious injury in as little as 2 hours or death, due to chemical burns and potential perforation of the esophagus.
  2. If you suspect your child has swallowed or inserted a button battery, immediately seek urgent medical assistance.
  3. Examine devices and make sure the battery compartment is correctly secured, e.g. that the screw or other mechanical fastener is tightened. DO NOT use if compartment is not secure.
  4. Dispose of used button batteries immediately and safely. Flat batteries can still be dangerous.
  5. Tell others about the risk associated with button batteries and how to keep their children safe.

SPECIFICATIONS

ULTRASONIC TECHNOLOGY
This humidifier uses ultrasonic, high-frequency technology to convert water into a fine mist that is dispersed evenly into the air.

ELECTRICAL RATING
120VAC 60Hz 100W 0.83A

UV-C TECHNOLOGY
UV-C technology reduces E. coli bacteria, Staphylococcus epidermidis bacteria, A. niger mold, and P. citrinum fungus in the mist. Shown by independent laboratory testing.

AUTO-SHUTOFF PROTECTION
When the tank is empty, the humidifier will shut off automatically. The out of water indicator will glow red.

CAPACITY
2.0 gallons –7.57 liters.

RUNTIME
Up to 12-120 hours. Runtime is based on setting the mist level on the low setting. Based on the natural humidity level in your home, the temperature of water you use, and the mist-level setting, you may experience longer or shorter runtimes.

ROOM SIZE
607 sq. feet / 56.3 sq. meters. Based on AHAM HU-1-2016 measurement as shown by independent laboratory testing.

QUIET OPERATION
26 dBA

REPLACEMENT PARTS

Contact Homedics Consumer Relations at cservice@homedics.com | 8:30am-7:00pm EST Monday-Friday 1-800-466-3342

WATER TANK

Model #: PP-UHEWMTF365WT

AROMA PADS

Model #: UHE-PAD1

DEMINERALIZATION CARTRIDGE

Model #: UHE-HDC4

REMOTE CONTROL

Model #: PP-UHEWMTF365RC

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION

No power

  • Unit is not plugged in
  • Unit is not turned on
  • No power at unit
  • Plug in unit
  • Press the power button to turn humidifier on
  • Check circuits and fuses or try a different outlet

Reduced or no mist

  • Humidifier has not warmed up
  • Low mist setting
  • Too much water in the water reservoir
  • Moving the humidifier with water in the tank
  • Scale build-up
  • Out of water
  • Water tank or water reservoir washed with detergent
  • Allow humidifier to run 20 minutes to warm up
  • Turn to a higher mist setting
  • Remove the water tank and pour out all water in the water reservoir. Replace the water tank. The water reservoir will refill automatically.
  • Too much water in the water reservoir. See solution above.
  • Clean following the Scale Removal instructions.
  • Fill the water tank
  • Rinse thoroughly with clean water until there is no foam or smell from detergent

Humidifier does not turn on or turns off during operation

  • Out of water
  • Room humidity higher than programmable humidistat setting
  • Auto mode
  • Fill the water tank
  • The humidifier has cycled off. Set the humidistat to a higher setting or to CO (continuous on).
  • Room humidity is higher than 56% RH. The humidifier will cycle on when the humidity drops below 55%RH.

Water overflows from water reservoir

  • Damaged water tank
  • Water tank outlet valve
  • Moving the humidifier with water in the tank causing too much water to enter the water reservoir
  • Tank not seated securely on the base
  • Check tank for cracks or damage
  • Debris prevents a watertight seal. Use your finger to open the valve and rinse with water.
  • Remove the water tank and pour out all water in the water reservoir. Replace the water tank. The water reservoir will refill automatically.
  • Empty all water from the water reservoir and place the water tank properly on the base. The water reservoir will refill automatically.

Peculiar odor

  • Unit is new
  • If unit is in use, the odor may be a dirty tank or old water in the tank and water reservoir.
  • Open the tank cover and let the tank air out in a cool, dry place for 12 hours
  • Clean following the Weekly Cleaning instructions. If odor persists, clean following the Scale Removal instructions.

Excessive noise

  • Unit is not level
  • Low water level
  • Place unit on a flat, even surface.
  • Check the water level; refill the tank if the water is low

White dust accumulation

  • Hard water used
  • Demineralization cartridge needs to be replaced
  • Use distilled water and a demineralization cartridge
  • Replace demineralization cartridge

Clean Reminder illuminates on the digital display

  • Transducer/Ultrasonic Membrane needs cleaning
  • Clean reminder needs to be reset
  • Follow Scale Removal instructions in the How to Clean and Care Section.
  • After filling the tank with water, press and hold the Night-Light button until the red out of water symbol turns off.

IMPORTANT SAFETY INSTRUCTIONS

WHEN USING ELECTRICAL PRODUCTS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS.


TO REDUCE THE RISK OF ELECTRIC SHOCK:

  • Always place humidifier on a firm, flat surface. A waterproof mat or pad is recommended for use under the humidifier. Never place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
  • Always unplug the unit from the electrical outlet immediately after using and before cleaning.
  • DO NOT reach for a unit that has fallen into water. Unplug it immediately.
  • DO NOT place or store the unit where it can fall or be pulled into a tub or sink.
  • DO NOT place or drop into water or other liquids.
  • DO NOT use water above 86°F.


TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:


  • Chemical burn hazard. Keep batteries away from children.

  • This product contains a lithium button/coin cell battery. If a new or used lithium button/coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
  • Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by Homedics; specifically, any attachments not provided with this unit.
  • NEVER drop or insert any object into any opening.
  • NEVER operate the appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a Homedics Service Center for examination and repair.
  • Always unplug the unit when filling or moving the unit.
  • Ensure that your hands are dry when operating the controls or removing the plug.
  • NEVER use the humidifier in an environment where explosive gases are present.
  • DO NOT place the humidifier near heat sources, such as a stove, and do not expose the humidifier to direct sunlight.
  • DO NOT carry this unit by the power cord or use the power cord as a handle.
  • To disconnect, turn all controls to the off position, then remove the plug from the outlet.


All servicing of this humidifier must be performed by authorized Homedics service personnel only.

SAVE THESE INSTRUCTIONS

PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.

  • This product is intended for household use only.
  • NEVER cover the unit while it is operating.
  • Always keep the cord away from high temperatures and fire.
  • Perform regular maintenance on the ultrasonic membrane.
  • NEVER use detergent to clean the ultrasonic membrane.
  • NEVER clean the ultrasonic membrane by scraping with a hard object.
  • DO NOT attempt to adjust or repair the unit. Servicing must be performed by professional or qualified personnel.
  • Stop using this unit if there is an unusual noise or smell.
  • Unplug this unit when not in use for a long period of time.
  • DO NOT touch the water or any parts of the unit that are covered by water while the unit is on or plugged in.
  • NEVER operate without water in the tank.
  • Only use water in the tank.
  • NEVER use any additive in the water including essential oils.
  • DO NOT wash, adjust, or move this unit without first unplugging it from the electrical outlet.
  • Keep this unit out of reach of children. Do not allow children to use this unit without supervision.
  • DO NOT use outdoors. For indoor use only.


DO NOT place a humidifier on furniture.
Always use a waterproof mat or pad on wooden surfaces.

FOR SERVICE IN THE USA
cservice@homedics.com
8:30am-7:00pm EST Monday- Friday
1-800-466-3342

FOR SERVICE IN CANADA
cservice@homedicsgroup.ca
8:30am-5:00pm EST Monday-Friday
1-888-225-7378

For more information regarding our product line in the USA, please visit www.homedics.com. For Canada, please visit www.homedics.ca.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Homedics 1714078 Manual

Advertisement

Need help?

Need help?

Do you have a question about the 1714078 and is the answer not in the manual?

Questions and answers

Table of Contents