Advertisement
*This item is accessed below the water tank. Water tank must be removed to access
ULTRASONIC TECHNOLOGY MIST OUTPUT SETTINGS 360° ROTATING MIST NOZZLE BUILT-IN TIMER 7 NIGHTLIGHT COLOUR OPTIONS | AUTO SHUT-OFF PROTECTION CAPACITY RUNTIME: 25 HOURS | OIL TRAY CLEAN TRANSDUCER/ULTRASONIC MEMBRANE |
Before filling the tank with water, turn the power off and unplug the unit from the outlet.
NOTE: Always use 2 hands to carry the water tank.
POWER ON/OFF & MIST OUTPUT LEVEL BUTTON
Plug unit into a 220-240V electrical outlet. Press the power button to turn unit on.
The humidifier will operate at low mist.
Long press power button for 2 seconds to switch between high and low mist output. Press again to turn the humidifier off.
360° ROTATING MIST NOZZLE
Rotate the mist output nozzle to adjust the mist direction.
AUTO-SHUTOFF PROTECTION
When the water in the tank is almost gone, the humidifying function will power off and the out of water LED will illuminate red, indicating it is time to refill the tank.
NOTE: It is normal to have a small amount of water in the tank and water reservoir after use.
NIGHTLIGHT
Press the nightlight button to turn the nightlight on. The nightlight will continuously scroll through the 7 colours. Press the nightlight button to stop scrolling and park on your favourite colour. Press the nightlight
button again to turn the nightlight off. The next time you turn the nighlight on, it will resume scrolling from the parked colour.
TIMER
Press the timer button. Keep pressing the timer
button until the desired timer setting is lit on the display. The timer
button will cycle through the following settings: 4 hours, 8 hours, 12 hours, off. To cancel the timer at any time, press the timer
button until all timer LEDs are off.
NOTE: It is normal to have a small amount of water in the reservoir during and after use.
OIL TRAY
Use the optional essential oil feature to disperse your favourite scent into the room. See essential oil instructions in the Essential Oil section.
CLEAN TRANSDUCER/ULTRASONIC MEMBRANE
CLEAN will illuminate red after 60 hours of use, indicating it is time to clean the transducer/ultrasonic membrane. See cleaning instructions in the Cleaning and Care section.
Use essential oil (not included) to deliver scent into the air.
NOTE: For use with the included HoMedics essential oil pads only. Do not add essential oils anywhere else in the unit as it may cause damage.
NOTE: Do not leave a filled essential oil pad in the humidifier if it will be out of use for a long period of time.
ARE ESSENTIAL OILS SAFE TO USE AROUND PETS?
We should always exercise caution when using essential oils around our pets. Keep all essential oil and aromatherapy products (like diffusers) out of reach of pets. Keep open bottles away from pets to avoid internal consumption. We do not recommend the topical use of essential oils on pets, as they have a strong sense of smell and cannot get rid of the oil if they don't like it or it is disturbing them. When diffusing essential oils around pets, always diffuse in a well-ventilated area and leave an option for them to remove themselves from the space, such as leaving a door open. Every animal is different, so carefully observe how each animal responds when introducing an essential oil for the first time. If irritation occurs, discontinue the use of the essential oil. We recommend seeking medical attention if ingestion of essential oil occurs.
ADDING ESSENTIAL OILS
Please note that allergy friendliness is no longer guaranteed if the Essential Oil Scent Tray function is used, since essential oils may lead to allergic reactions.
Putting oil anywhere but the oil tray will damage the humidifier.
To purchase genuine HoMedics Replacement Essential Oil Pads (model #PP-UHE-PAD1), HoMedics Essential Oils or new Demineralisation Cartridges, (model # PP-UHE-HDC4), contact your local retailer or visit www.homedics.co.uk.
ABOUT WHITE DUST
Use of high mineral content hard water may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. The mineral residue is commonly called "white dust." The higher the mineral content (or, the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier. It is caused only by minerals suspended in the water.
HOW AND WHY TO USE DEMINERALISATION CARTRIDGES
The HoMedics demineralisation cartridge will help reduce the potential for white dust, a deposit of minerals left behind from using hard water in your humidifier. The cartridge should be replaced every 30–40 fillings. The cartridge may need to be replaced more often if you are using very hard water. Replace the cartridge when you notice an increase in white dust buildup. If white dust still forms around the humidifier after a new cartridge has been installed, consider using distilled water. If you live in an area with hard water or use a water softener, we recommend using distilled water for best results. Never use water-softening additives in your humidifier.
INSTALLATION INSTRUCTIONS
Demineralisation Cartridge
Before cleaning, turn the unit off and unplug the unit.
CLEANING THE TRANSDUCER/ULTRASONIC MEMBRANE
(E-H)
The transducer/ultrasonic membrane must be cleaned as necessary to remove water mineral deposits. Failure to do so may cause reduced or no mist output.
NEVER touch the transducer/ultrasonic membrane with your fingers; the natural oils in the skin can damage the surface.
NEVER submerge the base in water or any other liquid.
TO CLEAN THE TANK (J)
TO CLEAN THE OIL TRAY (K)
Open the oil tray and remove the pad. Essential oil pads should be changed when switching to a different essential oil scent. If continuing to use the same scent, set the essential oil pad aside for reuse. Wipe down the inside of the oil tray with a soft cloth. Place the essential oil pad back in the tray and close.
NOTE: Leave the essential oil pad out of the oil tray when storing.
TO CLEAN THE SURFACE (L)
PROBLEM | POSSIBLE CAUSE | SOLUTION |
No power/no mist from spout |
|
|
Peculiar odour |
|
|
Excessive noise |
|
|
White dust accumulation |
|
|
READ ALL INSTRUCTIONS BEFORE USE. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
2 YEAR GUARANTEE
FKA Brands Ltd guarantees this product from defect in material and workmanship for a period of 2 years from the date of purchase, except as noted below.
For your local HoMedics Service Centre, go to www.homedics.co.uk/servicecentres
Manufacturer & Importer: EU Importer: |
Customer Support: +44(0) 1732 378557 | support@homedics.co.uk |