Download Print this page
McIntosh MIP200 Owner's Manual

McIntosh MIP200 Owner's Manual

Power controller

Advertisement

Quick Links

McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699 Phone: 607-723-3512 www.mcintoshlabs.com
M I P 2 0 0
M I P 2 0 0
P O W E R C O N T R O L L E R
O W N E R ' S M A N U A L

Advertisement

loading
Need help?

Need help?

Do you have a question about the MIP200 and is the answer not in the manual?

Questions and answers

Summary of Contents for McIntosh MIP200

  • Page 1 McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699 Phone: 607-723-3512 www.mcintoshlabs.com M I P 2 0 0 M I P 2 0 0 P O W E R C O N T R O L L E R...
  • Page 2 McIntosh with additional questions or in the unlikely event of needing service. MIP200 Rear Panel ..... .. 8 Rear Panel Connections and Switches ..8 McIntosh Laboratory, Inc.
  • Page 3 • AC Line Filtering 3. The Main AC Power going to the MIP200 and any The MIP200 offers EMI filtering that provides other component(s) should not be applied until all electromagnetic noise suppression to all compo- the system components are connected together.
  • Page 4 4.9 cm 7.5 cm INTOSH LABORATORY INC SERIAL BINGHAMTON NY NUMBER RS232 HANDCRAFTED IN USA MIP200 POWER CONTROLLER POWER CONTROL 3 POWER CONTROL 2 POWER CONTROL 1 MAIN POWER CONTROL WITH US AND IMPORTED PARTS CONTROL 100V - 120V ²³⁄32”...
  • Page 5 M I P 2 0 0 Dimensions (continued) Rack Mounting To rack mount the MIP200, the two included rack 19” mounting brackets should be installed. 48.3 cm Follow these instructions for each side: 1. Remove the two screws from the MIP200’s OUTLET CONTROL ”...
  • Page 6 5. DISPLAY CONTROL knob Rotate to select which of the three Indicates AC line monitor readings as well PUSH to turn the MIP200 on or off. Rotate SWITCHED OUTLETS are to be controlled. as options for the SWITCHED OUTLETS, to select various display options for the AC PUSH to access the trim menu.
  • Page 7 Power Control Connectors 100V - 120V Outlets 220V - 240V Outlets Safety Ground Safety Ground Power Control Meter Illumination Control Ground RS232 Connectors AC Line AC Neutral AC Line AC Neutral (Data transmitted by MIP200) Ground Safety Ground (Data recieved by MIP200)
  • Page 8 3. UNSWITCHED OUTLET 5. CIRCUIT BREAKER These outlets can be turned on and off using the This outlet is always on whenever the MIP200 is Should the MIP200 input current exceed its front panel OUTLET CONTROL knob or rear panel rating, the CIRCUIT BREAKER will activate and connected to a live AC circuit.
  • Page 9 A power control signal from TRIG 1 of the processor will then turn on the MIP200 front panel and then turn on the amplifier. The equipment rack fan is connected to SWITCHED OUTLET 3 which is configured to only come on with MAIN POWER CONTROL.
  • Page 10 MIP200 will be plugged into. Based Version __.__.__ configurations, a Setup Menu is provided to custom- on your version of the MIP200, this will be either Outlet 1 Remote, Delay, Name ize the operating settings using the Information 100, 110, 120 Volts, or 220, 230, 240 Volts.
  • Page 11 M I P 2 0 0 Outlet Submenu Delay Name Outlets 1, 2, and 3 each have their own submenu to configure them individually. To enter an outlet’s The Delay setting controls how long the outlet takes 1. To change the name of Outlet 1, rotate the submenu, rotate the OUTLET CONTROL knob in to turn on after a Remote Power Control signal.
  • Page 12 Trim Menu How to Select and Adjust Trim Functions Over Voltage 1. Press the Front Panel OUTLET CONTROL knob The Over Voltage protection feature will turn off all outlets if the AC line exceeds the set limit. This to open the Trim Menu. threshold can be configured to protect against 2.
  • Page 13 Display On and Off Switched Outlet Control To turn on the Information Display, push the The MIP200 has three Switched Outlets that are DISPLAY CONTROL knob. The MIP200 will go independently configurable. Rotate the OUTLET through a brief initialization, and then indicate the CONTROL knob to select the desired Outlet.
  • Page 14 Trademarks of McIntosh Laboratory, Inc.: The following are Registered Trademarks of McIntosh Laboratory, Inc. in multiple jurisdictions around the world: the written McIntosh logo; the McIntosh Globe logo; the Mc logo; Power Guard; Power Guard Screen Grid Sensor; Power Guard SGS; LD/HP; Dynamic Power Manager; the 4DPM8 logo; HXD; the HXD logo; Behind The Sound; Legendary Performance.
  • Page 15 Customer Service It is very important that the four plastic feet are 033836 Inside carton Department of McIntosh Laboratory. Refer to page attached to the bottom of the equipment. This 033725 Top / Filler pad 2.
  • Page 16 The continuous improvement of its products is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice. The MIP200 is designed to employ non- McIntosh-provided services some of which require separate customer subscriptions and some of which do not, as part of the Product’s functionality.