  • Page 1 Operating instructions (original) Water management SW 120 L Type 857 Language: EN Version: 1 Phone: 02874/9156-0 deconta GmbH Fax: 02874/9156-11 Date of issue: Im Geer 20 E-Mail: info@deconta.com 17.12.2024 46419 Isselburg Web: www.deconta.com...
  • Page 2: Table Of Contents

    Transport space ..................18 6.3.2 Legislation ....................18 6.3.3 Qualification of staff ................18 6.3.4 Warning of residual risks ................. 18 6.3.5 Means of transport .................. 18 Water management SW 120 L 2 from 33 Original operating instructions Version 1...
  • Page 3 13 Storage ........................... 31 14 Waste disposal....................... 32 14.1 Qualification of staff ....................32 14.2 Legislation ......................32 14.3 Waste ........................32 15 EC Declaration of Conformity ..................33 Water management SW 120 L 3 from 33 Original operating instructions Version 1...
  • Page 4: Product And Manufacturer

    Product and manufacturer Product and manufacturer Product The following product is described in these operating instructions: Water management SW 120 L Serial number: see type plate Manufacturer Name and address deconta GmbH Im Geer 20 46419 Isselburg Telephone 02874/9156-0 02874/9156-11 e-mail info@deconta.com...
  • Page 5: About These Operating Instructions

    The operator must keep these operating instructions or extracts thereof within easy reach in the immediate vicinity of the machine. If the machine is handed over to another person, the operator passes these operating instructions on to this person. Water management SW 120 L 5 from 33 Original operating instructions Version 1...
  • Page 6: Warnings

    Description of the hazard and the cause of the hazard Consequence Description of the possible consequences of the hazard for humans, animals and the environment Escape Recommendations on how hazards can be avoided Water management SW 120 L 6 from 33 Original operating instructions Version 1...
  • Page 7: Symbols

    The instruction sign is a safety sign that prescribes certain behaviour. The following table provides an overview of the instruction symbols used and their meaning. Symbol Meaning Symbol Meaning Wear safety shoes Use protective clothing Water management SW 120 L 7 from 33 Original operating instructions Version 1...
  • Page 8: Description Of The Machine

    This section contains information on understanding the machine. General description General description of the product The water management system was designed and built by deconta GmbH, Im Geer 20, 46419 Isselburg. Electric hot water cylinder for heating shower water. The water can be filled either manually via a filling opening (with bucket) or automatically with a permanently connected freshwater hose.
  • Page 9: Scope Of Delivery

    Description of the machine Scope of delivery The scope of delivery of the machine includes the following items: ▪ Water management SW 120 L ▪ Filters ▪ Service pack ▪ These operating instructions Return delivery after termination of a rental...
  • Page 10: Operating Modes

    Product - waste products: Geka connection for filtered wastewater into the sewage system ▪ Product - material feed: Geka connection for contaminated shower water ▪ Product - base: Wheels, feet Water management SW 120 L 10 from 33 Original operating instructions Version 1...
  • Page 11: Type Plate

    The following accessories are optionally available for water management: Designation Article no. Illustration Wastewater hose 5m with 3/4" Geka BU1504 connection Fresh water hose 5m with 1/2" Geka BU1504a connection Water management SW 120 L 11 from 33 Original operating instructions Version 1...
  • Page 12: Technical Data

    ▪ Heat output: 3000 W ▪ Useful water volume: 120 litres ▪ Tank filling: automatic or manual via filling opening ▪ Filter stages: ▪ Filter size: 10" Water management SW 120 L 12 from 33 Original operating instructions Version 1...
  • Page 13: Security

    For this reason, persons leaving the decontamination area via airlocks must take a shower when leaving. The deconta water management system heats the shower water and treats (filters) the contaminated wastewater.
  • Page 14: Misapplication

    Operating the machine in a technically unsatisfactory condition, not being aware of safety and hazards and not observing all instructions in the documentation Use in potentially explosive atmospheres Water management SW 120 L 14 from 33 Original operating instructions Version 1...
  • Page 15: Tasks And Qualifications Of Staff

    Qualified waste disposal Disposer Dispose of the machine company for legally compliant, proper and professional disposal of the machine Water management SW 120 L 15 from 33 Original operating instructions Version 1...
  • Page 16: Notes On Occupational Safety

    Instruction of persons with regard to protective devices and supplementary protective devices Instruction of persons with regard to residual risks This list is not exhaustive and does not claim to be complete. Water management SW 120 L 16 from 33 Original operating instructions Version 1...
  • Page 17: Transport

    Disconnect the appliance from the power supply. To empty, remove the Geka sealing cap on the "Empty tank" connection and open the ball valve. Cap Empty tank Ball valve Water management SW 120 L 17 from 33 Original operating instructions Version 1...
  • Page 18: Loss Of Warranty Claims

    Machine may fall down due to unintentional change of position when loading and unloading onto/from a means of transport. Water management SW 120 L 18 from 33 Original operating instructions Version 1...
  • Page 19: Internal Transport

    Machine may fall down due to unintentional change of position when loading and unloading onto/from a means of transport. Water management SW 120 L 19 from 33 Original operating instructions Version 1...
  • Page 20: Assembly

    This section contains information on the safe installation of the machine. The water management system is delivered ready for operation ex works and is intended for immediate commissioning. Do not operate the appliance if it is visibly damaged. Contact deconta GmbH immediately. Water management SW 120 L 20 from 33...
  • Page 21: Put Into Operation

    This section contains information on commissioning the machine. Wastewater IN 1 Wastewater IN 2 Hot water shower 2 Cold water shower 2 Cold water shower 1 Hot water shower 1 Water management SW 120 L 21 from 33 Original operating instructions Version 1...
  • Page 22 Connect "Hot water shower 2" connection to shower roof o Connect the "Cold water shower 2" connection to the cold water connection on the shower roof (if available) Water management SW 120 L 22 from 33 Original operating instructions...
  • Page 23 The wastewater pump can be switched on manually by pressing and holding the "Wastewater pump start" switch. Wastewater pump start Pump 1 + 2 Pump 1 Water management SW 120 L 23 from 33 Original operating instructions Version 1...
  • Page 24 => the pumps would not suck in the dirty water, but push the water back again! Waste water pump switch Water management SW 120 L 24 from 33 Original operating instructions...
  • Page 25: Operation

    Preset temperature (approx. 37°C). Do not change the settings on the heating element. Risk of scalding! Check the outlet temperature before every shower! Heating rod The picture shows the heating rod with the protective plate removed. Water management SW 120 L 25 from 33 Original operating instructions Version 1...
  • Page 26: Number Of Persons

    One person is required to use the machine. Tools required No tools are required to use the machine. Required equipment No equipment is required to use the machine. Water management SW 120 L 26 from 33 Original operating instructions Version 1...
  • Page 27: Maintenance

    Only change filters when the appliance is switched off. Only use approved filters. Pull out the mains plug before opening the housing Water management SW 120 L 27 from 33 Original operating instructions Version 1...
  • Page 28: Personal Protective Equipment Required

    Remove dirty filters when damp to prevent the release of filter dust ▪ Only use approved filters ▪ Damaged filter cartridges must not be used Union nut Pressure gauge filter monitoring Filter head spanner Water management SW 120 L 28 from 33 Original operating instructions Version 1...
  • Page 29: Reduction Of Legionella Growth

    To clean the hoses and shower device, the heated water should also be removed from the shower device for approx. 3 minutes. Caution: Danger of scalding! Alternatively, an authorised disinfectant can also be used. Water management SW 120 L 29 from 33 Original operating instructions Version 1...
  • Page 30: Spare Parts

    If this is not possible, the alternative spare parts should correspond to the properties of the original spare parts in order to ensure safe, trouble-free and economical use of the machine. Water management SW 120 L 30 from 33 Original operating instructions...
  • Page 31: Cleaning

    During storage, care must be taken to ensure that contamination with other substances is excluded. Drinking water hoses (freshwater hoses) and wastewater hoses must be stored separately. Water management SW 120 L 31 from 33 Original operating instructions Version 1...
  • Page 32: Waste Disposal

    The operator of the machine or the person authorised to dispose of the waste is responsible for compliance with these legal regulations. 14.3 Waste The waste generated by the machine must be disposed of properly and professionally in accordance with the law. Water management SW 120 L 32 from 33 Original operating instructions Version 1...
  • Page 33: Water Management Sw 120 L 2 From

    Safety of machinery - Safety-related parts of control systems - Part 2: Validation (ISO 13849-2:2012) Name and address of the person authorised to compile the technical documentation: Boland, Thomas - deconta GmbH - Im Geer 20 - 46419 Isselburg Place: Isselburg Date: 22.07.2024...