Download Print this page

Oxdale E300 Operating And Maintenance Manual

Hide thumbs Also See for E300:

Advertisement

Quick Links

Where to find us
Facebook
@OxdaleProducts
Instagram
@oxdaleproducts
Twi er
@oxdaleproducts
TikTok
@oxdaleproducts
Email
sales@oxdaleproducts.co.uk
Telephone
01246 529020
Loca on
Unit 20-21, Foxwood Road, Chesterfield, S41 9RF
Oxdale Products Ltd
OPERATING AND MAINTENANCE MANUAL
E300, E400 AND E400D LOG SPLITTER
KEEP FOR FUTURE USE

Advertisement

loading
Need help?

Need help?

Do you have a question about the E300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oxdale E300

  • Page 1 Oxdale Products Ltd Where to find us Facebook @OxdaleProducts Instagram @oxdaleproducts Twi er @oxdaleproducts TikTok @oxdaleproducts Email sales@oxdaleproducts.co.uk Telephone 01246 529020 Loca on Unit 20-21, Foxwood Road, Chesterfield, S41 9RF OPERATING AND MAINTENANCE MANUAL E300, E400 AND E400D LOG SPLITTER KEEP FOR FUTURE USE...
  • Page 2 CONTENTS  Safety Labels Quick Guide Including Transport and Storage In Depth Instruc ons Warranty Informa on Technical Specifica ons Contact Details Declara on of Conformity Electric Motor Instruc ons Other Informa on Manufacturer Oxdale Products Unit 20 – 21 Foxwood Road Off Sheepbridge Lane Chesterfield S41 9RF Year of Construc on 2023 Machinery Type E300 E400 E400D Mass of Machine Serial Number Max. Hydraulic Oil  Opera ng Pressure...
  • Page 3 Tel: 01246 529020 Email: sales@oxdaleproducts.co.uk Web: www.oxdaleproducts.co.uk The E300, E400 and E400D log spli ers are powered by a single- phase electricity supply and should be used in conjunc on with a PRCD (Portable Residual Current Device) circuit breaker. They can be used indoors or outdoors, but should be stored in a dry place.
  • Page 4 · Keep two hands on the opera ng leavers at all mes, never put hands or fingers between the wedge and the log to be split or near moving parts. Always stop the machine before cleaning it or making adjustments. ·...
  • Page 5 LABELS  The E300, E400 and E400D log spli er should have the following labels a ached. If any safety decals are missing or unreadable, they should be replaced immediately. SAFETY LABELS “Danger! Keep clear of moving parts!” Always keep hands and any loose clothing out of the way of moving parts, especially the spli ng wedge.
  • Page 6 QUICK GUIDE BEFORE FIRST USE  Before the log spli er can be used for the first me: · Fill the hydraulic oil tank with 15 litres of hydraulic oil 46 un l · visual contact on the sight glass can be seen. Plug the unit into the mains (single phase, 3 pin, 13-amp ·...
  • Page 7 3. Running Sound POST OPERATING CHECKS AND MAINTENANCE  Wipe off your log spli er with a damp cloth periodically to keep it During opera on of the motor there must be needed no rubbing sound free from debris. shrike and other random noise, you should stop the motor in me and begin to start it again only a er correc on has been done....
  • Page 8 6. Rota ng Condi on of the Motor Before the motor is installed the sha extension slowly should be turned Level Gauge by hand to make sure that the rotor does not rub or knock against other parts but gives an easy and swi rota on.A er the motor has been installed, check the driving belt or the coupler is mounted with good flexibility....
  • Page 9 The log spli er is designed for spli ng logs only AND IS FOR SINGLE PERSON USE. It can handle logs no bigger than 450mm (300mm on the E300) and having a diameter no bigger than 900mm and no smaller that 75mm in diameter. 3. Inspec on of the Switch Only persons who are competent to do so and having read this manual, in full, should use the log spli er.
  • Page 10 1.Transporta on With  both  hands,  clasp  both  leavers  and  During transporta on, care must be taken to keep the motor in push up to lower the wedge. upright posi on and place it flat, without being inverted or laterally laid. When being craned, it should be li ed or lowered slowly.
  • Page 11 Post Opera on and Maintenance Instruc ons At the end of each day’s work, the unit should be cleaned. The removal of wood chips etc from the unit is advisable as well as removing contaminated grease from the wedge collar. Sharpen the wedge as and when required, this can be done with a file. Check for any loose bolts or other damage at regular intervals.
  • Page 12 Check the oil level once it has been run and top up as required. Electric Motor The electric motor unit should only be opened by a qualified electrician. Oxdale Products Ltd recommends annual servicing and PAT tes ng by a qualified electrician.
  • Page 13 Oxdale authorised dealers. No liability is accepted for damages caused by incorrect repairs, the non-use of original Oxdale replacement parts or repairs that have not been carried out by Oxdale or a pre-authorised specialist, the same applies to auxiliary parts and accessories.
  • Page 14 TECHNICAL SPECIFICATIONS E300, E400 AND E400D MS、MC、MY、ML、MS2 Series LOG SPLITTER MODEL NO.  ASYN. MOTORS INSTRUCTION FOR OPERATION AND MAINTENANCE Weight 60kg Max Pressure 4780psi/330 Ram Bore 60mm Noise <70db(A) Ram Stroke 300mm and Ram Rod 40mm Kramp Pump Saturn Group 2 Input Speed 1450 rpm Torque 33n/m Displacement 3.2 cc/rev Flow 4.3 l/min 250 bar / 3625...