HEATERS, INSERTS, PELLET BOILERS
----

Advertisement

loading
Need help?

Need help?

Do you have a question about the Hydro 13 and is the answer not in the manual?

Questions and answers

Summary of Contents for EVA Stampaggi Hydro 13

  • Page 1 Translation of copy in original language IMPORTANT: MUST BE READ 831011800 rev. 1.0 12/04/2022 Installation, use and maintenance manual HEATERS, INSERTS, PELLET BOILERS ----...
  • Page 2 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS TABLE OF CONTENTS 1 PRODUCT SAFETY 2 HANDLING AND UNPACKING 3 MINIMUM INSTALLATION REQUIREMENTS 4 INSTALLATION 4.1 FLUE PIPE 4.2 CHIMNEY COWL 4.3 DRAUGHT 4.4 STOVE EFFICIENCY 4.5 AIRTIGHT STOVE ONLY 4.6 INSTALLATION PLACE 4.7 CONNECTION TO THE FLUE PIPE 4.8 INSTALLATION EXAMPLES...
  • Page 3 Each stove is subjected to internal testing before shipment and as such residues inside the appliance may be found. Eva Stampaggi aims to provide as much information as possible to ensure safer use and to avoid damage to persons, property or parts of the stove itself.
  • Page 4 ● Read the manual carefully: ● Eva Stampaggi S.r.l. assumes no responsibility for damage to persons and/or property or for the malfunction of the stove resulting from non-compliance with the provisions of this Instruction Manual ● The guarantee will remain valid for 1 year for professional operators and 2 years for consumers ●...
  • Page 5 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS ATTENTION ATTENTION! DO NOT TOUCH the FIRE DOOR, the GLASS, the HANDLE or the FUME OUTLET DURING FUNCTIONING if not wearing adequate protective devices since they become extremely hot! ●...
  • Page 6 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS ATTENTION These stoves operate exclusively with pellets and olive pomace if the stove is designed for it; DO NOT USE DIFFERENT COMBUSTIBLES: any other material burned will cause the apparatus to malfunction. ATTENTION Clean the burn pot on a regular basis upon every ignition or pellet refuelling.
  • Page 7 INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED. INSTEAD THE FUME OUTLET MUST BE ROOF- TYPE AS PROVIDED FOR BY NATIONAL REGULATIONS. Eva Stampaggi S.r.l. assumes no responsibility for damage to persons and/or property caused by non-compliance with the point highlighted above for products installed in a non-compliant manner.
  • Page 8 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS 3 issuing of additional documentation - the installer's responsibility. The release of technical documentation must include: ● use and maintenance manual for the appliance and the components of the system (e.g. smoke channels, chimney flue, etc.);...
  • Page 9 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS INSTALLATION FLUE PIPE THE PRODUCTION OF STOVES WITH HIGHER PERFORMANCE IS INCREASINGLY REQUIRED SO IT IS BECOMES ESSENTIAL TO ENSURE THAT INSTALLATIONS COMPLY WITH THE LAW. IF THE VENT PIPE PASSES THROUGH NON-HEATED ENVIRONMENTS, IT MUST BE INSULATED FOR CORRECT COMBUSTION.
  • Page 10 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS CHIMNEY COWL A properly installed chimney cowl ensures optimum stove functioning. The anti-downdraught chimney cowl consists of a number of components whose outlet section sum always doubles the flue pipe section. Make sure the chimney cowl is at least 150cm above the roof rise so that it is fully exposed to the wind.
  • Page 11 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS DRAUGHT Fumes heat up during combustion, increasing their volume. Their density is therefore lower than the one of the surrounding colder air. This difference between the inside and outside temperatures of the chimney results in a negative pressure which increases proportionally to the vent pipe length and the temperature.
  • Page 12 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS ATTENTION Read the manual carefully: Before installing, the following indications must be met: Select the position where the stove is to be installed and: ● Arrange the connection to the vent pipe for fume extraction. ●...
  • Page 13 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS INSTALLATION PLACE ATTENTION Read the manual carefully: ● When the stove is on, it can create a depression in the room where it is installed, therefore there must not be any open flame apparatus in the same room, with the exception of type C boilers (airtight).
  • Page 14 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS CONNECTION TO THE FLUE PIPE THE LENGTH OF THE FUME DUCT PIPE MUST HAVE A DIAMETER EQUAL TO OR GREATER THAN THAT SPECIFIED FOR EACH APPLIANCE. EVERY 90° ELBOW OR (T) COUPLING IS THE EQUIVALENT OF 1 METRE OF PIPE.
  • Page 15 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS INSTALLATION EXAMPLES Key: T - T fitting; Ø ST - Stove diameter T; RAC Ø ST Ø CF - Stove and smoke duct connection; Ø CF - Smoke duct diameter; IS - Insulator;...
  • Page 16 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS ELECTRICAL CONNECTION The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance. Special attention should be paid when the operation is a supplementary action and all equipment must operate as planned.
  • Page 17 Heaters Inserts Fumes Exhaust (A) = 80 mm Primary Air (B) = 42 mm Heating return (C) = 3/4 inch Heating output (D) = 3/4 inch Hydro 13 Hydro 17 Insert 18 Insert 24 Hourly consumption (kg/h) 0.72 Chimney draught (Pa) Fumes temperature (°C)
  • Page 18 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS Heater Fumes Exhaust (A) = 80 mm Primary Air (B) = 42 mm Heating return (C) = 3/4 inch Heating output (D) = 3/4 inch Upper fumes exhaust (Hydro kantina only) = 80 mm Hydro 20 Hydro 24 Hydro kantina 20...
  • Page 19 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS BOILERS EV 34 / EV 50 PRO 20 / PRO 24 Fumes Exhaust (A) = 100 mm Primary Air (B) = 50 mm Heating return (C) = 1 inch Fumes Exhaust (A) = 100 mm Heating output (D) = 1 inch Primary Air (B) = 50 mm...
  • Page 20 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS Maximum fuel humidity (%) Tank capacity (kg) Expansion tank (L) Maximum allowable temperature (°C) Boiler water thermostat 30-80 30-80 30-80 30-80 adjustment values (°C) Minimum return temperature (°C) Boiler type Not condensing Not condensing Not condensing...
  • Page 21 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS PARTICULARS OF INSTALLATION EXAMPLES OF PLANT DIAGRAMS 831011800 - 1.0 - 12/04/2022...
  • Page 22 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS SELECTION OF THE TYPE OF PLANT Inside the electronic control unit there is a PLANT TYPE function. This function offers the choice of 2 types of system: Type 1: plate heat exchanger (Si boilers) Type 2: Thermostat Boiler (No Boilers) Type 3: thermostat buffer (No boilers) Type 4: probe boiler (No boilers)
  • Page 23 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS HYDRO INSERT INSTALLATION PROCEDURE FOR THE CORRECT INSTALLATION OF THE PRODUCT INTRODUCTION: The minimum product dimensions and openings for correct air circulation must be taken into account when installing to prevent the item from overheating.
  • Page 24 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS PELLET STOVES INSTALLATION It is necessary to follow all the instructions described above. Attention to the installation of the flue material and the smoke channel: the fumes are very low so the possibility of condensation is very high. Use condensate resistant components. DOMESTIC WATER KIT If the stove with DOMESTIC WATER KIT was purchased, the entry of domestic cold water and the outlet of domestic hot water must also be provided.
  • Page 25 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS SET CRONO MENU Submenu – Enable chrono: Allows every chrono-thermostat function to be enabled or disabled. Sub-menu – Daily chrono: The daily programmable chrono-thermostat functions can be enabled, disabled and set. In each program you will find: Switch- on time, Switch-off time, Set stove heat output, Room temperature, Days of the week for which the programme is to be active.
  • Page 26 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS INITIAL LOAD This function is only available when the stove is OFF and is used to load the auger when the stove is started for the first time when the pellet hopper is empty. After selecting the menu, press P1. The exhaust blower switches on at the maximum speed and the auger tube (auger tube LED on) starts working.
  • Page 27 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS Changing set room temperature Press the P2 button to change the set room temperature. The display shows the set room temperature (SET temperature value). Press P1 (increase) and P2 (decrease) buttons to modify the temperature. The value is saved after approx. 5 seconds and the display goes back to normal.
  • Page 28 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS ALARMS In the event that an operating fault occurs, the board intervenes and signals the occurrence of an irregularity, switching on the alarm LED (alarm LED on) and emitting acoustic signals. The possible alarm messages are listed below: Display shows Cause POWER OUTAGE ALARM...
  • Page 29 ATTENTION Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused by the failure/incorrect cleaning and routine maintenance of the stove.
  • Page 30 ---- - HEATERS, INSERTS, PELLET BOILERS ATTENTION Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction and those resulting from people or things caused by the failure/incorrect extraordinary maintenance of the stove. It is not uncommon, at the first cold spell and with wind for fires to ignite in the chimney due to the residue build up; some advice in the unfortunate event of this happening is: ●...
  • Page 31 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS TROUBLESHOOTING FIRST START-UP FIRST START-UP IT MAY BE NECESSARY TO REPEAT THE FIRST LOAD PHASE A FEW TIMES TO FACILITATE THE APPLIANCE INITIAL START-UP AS THE AUGER TUBE IS COMPLETELY EMPTY AND IT MAY TAKE A SPECIFIC PERIOD OF TIME TO FILL.
  • Page 32 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS PROBLEM CAUSE SOLUTION POWER OUTAGE CHECK PLUG AND POWER SUPPLY OR ON/OFF SWITCH CALL TECHNICAL ASSISTANCE. FAULTY ELECTRICAL CABLE CALL TECHNICAL ASSISTANCE. DISPLAY INTERRUPTED FUSE IN CONTROL SWITCHED OFF BOARD CALL TECHNICAL ASSISTANCE.
  • Page 33 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS PROBLEM CAUSE SOLUTION STOP FIRE CLN-BURN POT PERIODIC CYCLE OF BURN POT CORRECT OPERATION. CLEANING CLEAN BURN POT CLEAN BURN POT ALAR DEP FAIL FIREPLACE NOT COMPLIANT, MAX 6 METRES OF TUBE ACTIVE ALARM EXCESSIVE OR INADEQUATE VENT WITH Ø...
  • Page 34 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS PROBLEM CAUSE SOLUTION (FIELD SEARCH) REMOTE CONTROL HAS LOST THE PRESS THE KEYS 1 AND 2 SIMULTANEOUSLY FOR REMOTE CONTROL UNIT ABOUT 3-4 SECONDS UNTIL THE "CHOOSE UNIT" DOES NOT APPEARS POSSIBLE INTERFERENCE CONNECT...
  • Page 35 Installation, use and maintenance manual ---- - HEATERS, INSERTS, PELLET BOILERS 11 INSTALLATION AND TEST CERTIFICATE CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER STREET/ROAD: CITY: POSTAL CODE: PROVINCE TEL: Delivery date: Delivery document: Equipment mod.: Serial number: Year: DEALER and INSTALLER DATA First name: Last Name: Address:...
  • Page 36 EN 303-5:2012 (pellet boilers) Eva Stampaggi S.r.l. guarantees that the stove is free from defects that make it unsuitable for its intended use or significantly reduce its value. The rules of the Italian Civil Code or applicable national law governing the guarantee in the sales contract, or applicable national law ex D.
  • Page 37 AN INSTALLATION ACCORDING TO THE LAW IS MANDATORY, EVA STAMPAGGI STRONGLY RECOMMENDS A FIRST IGNITION OF ITS PRODUCTS WITH A QUALIFIED TECHNICIAN. EVA STAMPAGGI HAS NO LIABILITY OF ONLINE SALES AND RELATED OFFERS, BECAUSE IT DOES NOT MAKE DIRECT SALES TO THE GENERAL PUBLIC.