ENG | Instruction Manual
LK 450 EasyHeat M
9 kW
PAGE
LANGUAGE
1.
English
6.
Deutsch
11.
Français
16.
Italiano
21.
Suomi
26.
Svenska
TECHNICAL DATA
Voltage
Max. boiler efficiency
Working temperature
Min. supply temp.
Max. supply temp.
Max. working pressure
Media
Thread standard
Circulating pumps
Sound level
Electrical connection
Protection type
Level guard
Expansion vessel
Overheating protection
Type approval
The LK 450 EasyHeat M (manual) 9 kW is a complete portable
electrically heated boiler. It is primarily meant to be used as a
temporary heater, e.g. for drying concrete slabs with underfloor
heating and for heating buildings under construction.
With the LK 450 EasyHeat M, setting the required constant tempe-
rature between 8 and 60 °C is easy.
With its built-in water level detection, damage to the immersion
heater is prevented if the water level in the system gets too low.
EasyHeat comes in a blue aluminium cabinet with inspection win-
dow, so you can monitor the unit during operation. The cabinet can
be locked to prevent accidental changes to the set temperature.
Available accessories
•
The LK 321 MultiFill® makes it easy to fill the system.
•
The LK 522 filterball magnet is used to protect EasyHeat from
dirt and magnetite.
•
Transport trolley to simplify moving the unit.
•
Connection pipes for easy connection between EasyHeat and
the heating system. Refer to accessories & spare parts.
1
230 V
9 kW
8-60 °C
8 °C
60 °C
3 bar
Water/glycol mix max. 30 %
G – female thread
Wilo Para 15/6 – Composite
< 30 dB
CEE socket 16 A/400 V/50 Hz/
triple phase
IP44
Yes
6 l
80 °C
www.lkarmatur.com
SAFETY INSTRUCTIONS
•
Read the user manual before putting the product into opera-
tion.
•
The safety instructions must be followed at all times.
•
Modifications made to the product will void the warranty.
•
LK Armatur disclaims all responsibility for damages caused
by the use of devices, accessories or spare parts not approved
by the manufacturer.
•
Damage caused by substandard third-party components will
void the warranty.
•
Repair work on the product must be carried out by qualified
personnel.
•
Make sure the unit is placed on a flat surface free of obsta-
cles.
•
Pipes and cables must be placed in such a way that they do
not pose a risk of danger. In cases where this is not pos-
sible, attention must be drawn to pipes and cables with extra
marking.
•
Any external power supply must always be secured with a
ground-fault circuit breaker.
STORAGE OF UNIT
•
Store indoors, frost-free. Temperature 5-45 °C.
•
Relative humidity from 20 to 70 %.
DISCLAIMER
LK Armatur takes no responsibility for the program choices and
settings the user makes to achieve the intended heating purpose.
This product is designed to meet the requirements of the relevant
EU directives. To maintain this status all repair and maintenance
must be carried out by qualified personnel using only original
spare parts.
Need help?
Do you have a question about the LK 450 EasyHeat M and is the answer not in the manual?
Questions and answers