Fault Code; Technical Specifications - ATIKA ALE 600 Original Instructions Manual

Air dehumidifier
Hide thumbs Also See for ALE 600:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12

Fault code

Following fault codes can be indicated in the display 2 "Relative humidity of air":
Fault code
Fault
E3
Humidity sensor defective.
E4
Water collecting container full.
E5
Refrigeration circuit sensor defective.
Please contact the manufacturer or customer service of the fault codes E3 or E5 appear.
T
e
c
h
n
i
c
a
l
s
p
e
c
i
f
T
e
c
h
n
i
c
a
l
s
p
e
c
i
f
Type
Model
Air flow rate
Rated power
Rated current consumption
Max. power
Max. current consumption
Power, fan
Electrical power supply
Power system fuse protection
Temperature range
Humidity of air range
Dehumidification performance at 30 °C / 80% RH
Degree of protection
Freezing pressure
Vapour pressure
Refrigerant
Refrigerant quantity
Container volume, max.
"Tank full" LED comes up at
Room volume (at a ceiling height of 2.5 m)
Room area
Sound power level L
WA
Sound power pressure L
PA
Weight
18
i
c
a
t
i
o
n
s
i
c
a
t
i
o
n
s
HT 600
ALE 600
680 m³/h
1000 W
4.6 A
1200 W
5.4 A
50 W
230 V~ / 50 Hz
10 A
5 – 32 °C
30 – 90% rel. humidity of air
60 l / 24 h
IP X0
2.5 MPa
1.0 MPa
R 407 C
0.6 kg
5.8 l
3.9 l
150 – 200 m³
60 – 80 m²
< 70 dB (A)
53 dB (A)
51.5 kg
HT 800
ALE 800
680 m³/h
1200 W
5.3 A
1410 W
6.4 A
50 W
230 V~ / 50 Hz
10 A
5 – 32 °C
30 – 90% rel. humidity of air
80 l / 24 h
IP X0
2.5 MPa
1.0 MPa
R 407 C
0,78 kg
5.8 l
3.9 l
250 – 300 m³
100 – 120 m²
< 70 dB (A)
53 dB (A)
53.5 kg