  • Page 1 Bray Commercial Division 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 www.braycommercialdivision.com © 2022 Bray International, Inc. 08/08/23 SoftTouch 2 Ball Valves (ST2) - 2-Way & 3-Way, 2" – 2" IOM Manual...
  • Page 2 Disclaimer - The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications consult the local Bray office. Bray, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
  • Page 3 IMPORTANT: Contact your local Bray representative for compatibility concerns before using ST2 Series Ball Valves to control the flow of fluids other than those outlined in the Technical Specifications table in this...
  • Page 4 Softtouch 2 Installation, Operation & Maintenance Manual Continued Installation Install ST2 Series Ball Valves with the actuator at or above the centerline of the horizontal piping, as shown in Figure 1. Port C Port A Common Coil Port C Port A...
  • Page 5 SoftTouch 2 Installation, Operation & Maintenance Manual Continued Press Valve Installation Sweat Valve Installation ST2 press end connection valves are installed using When soft soldering sweat ball valves, be sure to RIDGID® press tools. Always refer to the operator’s use a low temperature solder with a melting point manual supplied with the RIDGID press tool that is that does not exceed 450°F (232°C).
  • Page 6 Softtouch 2 Installation, Operation & Maintenance Manual Continued SoftTouch 2 - 2-Way Piping Schematics Return Port A Port B Supply Typical Two-Way Ball Valve Application Note : Mount the valve downstream from the coil to minimize heat transfer to the actuator.
  • Page 7 SoftTouch 2 Installation, Operation & Maintenance Manual Continued Port Marking Locations 2-WAY - VALVE BODY DIMENSIONS in. (mm) ST2 Valve Size Model # Prefix ST2-05-2-... 2-1/2 (64) 5/8 (17) 1-7/32 (31) 11/32 (9) ST2-75-2-... 2-13/16 (71) 5/8 (17) 1-7/32 (31) 11/32 (9) ST2-1-2-...
  • Page 8 Softtouch 2 Installation, Operation & Maintenance Manual Continued COMMERCIAL ACTUATOR DIMENSIONS in. (mm) Direct Mount Weight Actuator Model Length Width Height lbs. (kg) Number VA(M)-35 Series 5.2 (132) 2.8 (71) 2.1 (53) 1.3 (0.59) VA(M)S-27 Series 6.4 (163) 3.3 (84) 2.3 (58)

This manual is also suitable for: