Summary of Contents for Schlage PIM400-1501-LC

  • Page 1 *23855075* 23855075 PIM400-1501-LC User Guide Installation and operating instructions for Schlage PIM400-1501-LC Para el idioma español, navegue hacia www.allegion.com/us Pour la portion française, veuillez consulter le site www.allegion.com/us...
  • Page 2 Remote antenna (if applicable) ..................10 Antenna location and safety ..................10 Antenna grounding ......................10 Terminate the coax whip at the PIM400-1501-LC ............11 Reset to factory defaults ....................12 Reset the PIM400-485 to factory defaults ..............12 Reset the LP1501 to factory defaults - bulk erase ............12 Memory backup battery ....................12...
  • Page 3 P516-781). Once the LP1501 board is installed, the PIM400-1501-LC operates as the PIM400-1501-LC as described in this guide. For UL installations, the PIM400-1501-LC must be used with an LP1501 board that is UL294 listed. The PIM400-1501-LC communicates over Ethernet to host software, and by wireless transmission with up to 16 AD-Series Wireless Access Point Modules (WAPMs).
  • Page 4 • This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70. • Category 5e cabling is the minimum performance category recommended. 4 • Schlage • PIM400-1501 user guide...
  • Page 5 Status LEDs S2, Reset LP1501 Ethernet Input Power Switch Cable J3, PoE/12VDC Selector Jumper S1, Dip Switches USB Cable Tamper Switch Mounting Mounting Hole Hole Ethernet Connector Connector PIM400-1501-LC Printed Circuit Board Assembly 5 • Schlage • PIM400-1501 user guide...
  • Page 6 To initiate linking, place the PIM400-1501-LC in link mode first, then place the desired WAPM in link mode. 1. Place the PIM400-1501-LC into link mode. Refer to the SUS user guide for detailed Link instructions. 2. Place the desired WAPM into link mode. Refer to instructions in the “Linking” section of the user guide for the WAPM.
  • Page 7 2. Temporarily mount the PIM400-1501-LC in the exact location and orientation it will be mounted. 3. Power the PIM400-1501-LC with a 12 VDC supply capable of delivering 400 mA or PoE, Class 3, 12.95W, fully compliant to IEEE 802.3af. For UL installations, PoE powered devices shall not be used. Power for these...
  • Page 8 1. Place the PIM400-1501-LC, cover removed, against the wall in the position where it successfully linked. 2. Orient the PIM400-1501-LC vertically with the radio board at the top of the enclosure. 3. Drill four holes, ⁹⁄32” diameter drill bit, 1¾” deep, located to match the mounting holes as shown on page 3.
  • Page 9 Set the PoE/12 VDC power selector jumper (J3) to “12V”. PoE Input Power • If powering the PIM400-1501-LC with PoE, there is no need for a hole to be drilled in the PIM400-1501-LC enclosure to accommodate power. Power is delivered through the Ethernet cable.
  • Page 10 Network connection Ethernet connection Connect a live Ethernet connection to the Ethernet port on the PIM400-1501-LC. The green LED on the PCBA Ethernet port will light up when a live network connection is present. The PIM400-1501-LC is shipped with the factory default network settings shown below.
  • Page 11 Terminate the coax whip at the PIM400-1501-LC Only applicable to installations using an optional remote antenna. 1. Drill a ⅝” (16 mm) hole in the top of the PIM400-1501-LC enclosure as shown to accommodate the mounting of the coax whip to be connected to the PIM400-1501-LC radio board.
  • Page 12 4. The two green lights beside the link buttons will blink 3 times when the reset is complete. 5. Replace the main cover. Reset the LP1501 to factory defaults - bulk erase Refer to the Mercury LP1501 user guide for more information. 12 • Schlage • PIM400-1501 user guide...
  • Page 13 PIM400-1501-LC LED reference 13 • Schlage • PIM400-1501 user guide...
  • Page 14 Note: The intended use of this module is not for the general public. It is generally for industry/commercial use only. This transceiver is to be professionally installed in the end product by Allegion, and not by a third party. The Schlage XPB-COMAD400V3 900 MHz Communication Board Module will not be sold to third parties via retail, general public or mail order.
  • Page 15 To comply with IC RF exposure limits for general population/uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. 15 • Schlage • PIM400-1501 user guide...
  • Page 16 Customer Service © Allegion 2023 Printed in U.S.A. 1-877-671-7011 www.allegion.com/us 23855075 Rev. 08/23-g...