Download Print this page
Rohnson R-8916 Instruction Manual
Hide thumbs Also See for R-8916:

Advertisement

Quick Links

EN
Portable Air conditioner R-8916
Manual Instructions
Portable Air conditioner R-8916
Please read this manual thoroughly before using it and save it for future
reference.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the R-8916 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rohnson R-8916

  • Page 1 Portable Air conditioner R-8916 Manual Instructions Portable Air conditioner R-8916 Please read this manual thoroughly before using it and save it for future reference.
  • Page 2 Portable Air conditioner R-8916 SAFETY INSTRUCTIONS Important •Carefully read the instructions before operating the unit. •This appliance is for indoor use only. •Rating: This unit must be only connected to a 220-240V / 50 Hz earthed outlet. The fuse rating can be found on the plug itself.
  • Page 3 Portable Air conditioner R-8916 •An authorized service representative should perform any service other than regular cleaning or filter replacement. Failure to comply could result in a voided warranty. •Avoid touching any moving parts of the appliance. •Never insert fingers, pencils or any other objects through the guard.
  • Page 4 Portable Air conditioner R-8916 •The air conditioners contain the following quantity of refrigerant gas: R-8916 230g •Do not install or store in an unventilated space with an area smaller than shown in the table below per system. Smaller room sizes may be...
  • Page 5 Portable Air conditioner R-8916 •The refrigerant system should not be perforated or punctured. •At the end of the unit’s lifetime, always dispose in line with local regulations. •Ensure all storage conditions in the manual are followed. •WARNING: Do not use means to accelerate the defrosting process or to clean the unit.
  • Page 6 Portable Air conditioner R-8916 •For the initial start-up, set the fan speed to maximum and the thermostat to 5 degrees lower than the current temperature. Afterwards, set the fan switch low and set the thermostat to your desired setting. •...
  • Page 7 Portable Air conditioner R-8916 PART LIST...
  • Page 8 Portable Air conditioner R-8916 INSTALLATION WARNING: Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit, please note that it must always be kept upright and placed on an even surface.
  • Page 9 Portable Air conditioner R-8916 3) Clip the Exhaust adaptor into position on the rear of the unit (To remove the adaptor, press the clips down to release it from the unit). 4) Make sure the unit is upright, and there are no obstructions to the air inlets and outlet grills, with at least 50cm of space to the side and rear of the unit.
  • Page 10 Portable Air conditioner R-8916 INSTALLATION OF THE WINDOW KIT The window kit (slide bar and fishtail adapter) can be used with sliding windows and doors. For other types of windows, the fishtail adaptor should be used on its own. 1. Slide the rear section of the slide bar onto the front section, lining up the plate so it runs within the groove.
  • Page 11 Portable Air conditioner R-8916 3. Partially open the window and place the extended slide bar in position before closing the window onto it. 4. Fix the fishtail adaptor into the opening on the slide bar. NOTES: •The window kit is only designed to be installed with sliding or sash windows or doors.
  • Page 12 Portable Air conditioner R-8916 IMPOTANT SAFEGUARDS The length of the soft hose extends from approximately 30cm to 180cm. If the hose is extended above this length, the unit may malfunction, which can invalidate the warranty. The outlet vent must be well-ventilated and not obstructed, as this will cause the unit to overheat.
  • Page 13 Portable Air conditioner R-8916 OPERATION Press the POWER button to turn the unit ON or OFF. Press the MODE button to cycle between the 4 modes, and the indicator for the selected mode will be illuminated. COOL: The room is cooled with the cold air expelled through the front air outlet while hot air is expelled through the vent pipe.
  • Page 14 Portable Air conditioner R-8916 speed is automatically adjusted based on the amount of cooling required. Attempts to change the fan speed will move the unit into COOL mode. Press the SPEED button to change between the 3 fan speeds. The display and LEDs will indicate the currently selected fan speed.
  • Page 15 Portable Air conditioner R-8916 both buttons together to change between displaying the temperature in Celsius and Fahrenheit. Use to enable the swing function. Press SWING to activate and deactivate the up-down swing. Press and hold SWING for 3 seconds to activate and deactivate the left-right swing.
  • Page 16 Portable Air conditioner R-8916 Press to turn the unit on or off. Press to change between Cooling, Fan, Dry and AUTO Modes. Press to turn the timer on or off. Press to adjust the fan speed. Press the sleep button to enter sleep mode.
  • Page 17 Portable Air conditioner R-8916 MULTI PROTECTIVE FUNCTIONS FROST PROTECTION In COOL, DRY or AUTO modes, if the temperature of the exhaust is too low, the machine will automatically stop operating until the temperature has risen. OVERFLOW PROTECTION When the water in the internal water tank exceeds the warning level, the machine will stop operating and sound an alarm with the LCD showing “E4”.
  • Page 18 Portable Air conditioner R-8916 AUTOMATIC THERMAL PROTECTION To protect the service life of the machine, the machine has automatic thermal protection. If the temperature within the unit is outside of the specified range, the compressor and the lower motor will stop operation.
  • Page 19 Portable Air conditioner R-8916 substances may cause damage to the surface and or the internal workings of the machine. AIR FILTER CLEANING If the filter screen is clogged with dust, the air conditioner’s effectiveness is reduced. The filter screen should be cleaned once every two weeks or as often as necessary in your environment.
  • Page 20 Portable Air conditioner R-8916 1) PUMP ASSISTED DRAINAGE Remove the rubber stopper from the upper drain port. Connect a drainage pipe (12mm internal diameter) to the drain port, and route it to a suitable drain. Press and hold the SMOOTH AIR button to start the pump and drain the water tank.
  • Page 21 Portable Air conditioner R-8916 NOTE: This models has a self-evaporative function, which reduces the need to empty the water tank in cooling mode. If the unit is vented correctly, most of the water is reused to cool the condenser coils, and any excess is evaporated.
  • Page 22 Portable Air conditioner R-8916 1. Remove the rubber stoppers from the drainage holes and empty the internal tank. Tou can also drain the water by leaning the unit backwards. 2. Run the unit in fan mode, with a low fan speed, with the rubber stopper still removed and a container under the lower drain port.
  • Page 23 Portable Air conditioner R-8916 “E4” inside. The ambient Only use the machine temperature is too low within a temperature or too high. range of 7-35°C In cooling mode, the Change the desired room temperature is temperature. lower than the desired temperature.
  • Page 24 Portable Air conditioner R-8916 The compressor does Overheat protection Wait 3 minutes until not work. starts. the temperature is lowered, then restart the machine. The remote control The distance between Let the remote control does not work. the machine and the...
  • Page 25 Portable Air conditioner R-8916 work, please get in touch with the Service Centre. 1. Has the unit been standing upright for at least 2 hours? 2. Is the unit plugged into the mains? 3. Is the fuse, OK? 4. Switch the unit off and wait three minutes to see if the issue is resolved.
  • Page 26 Portable Air conditioner R-8916 IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2012/19/EU. At the end of its working life, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection center or to a dealer providing this service.