Download Print this page
Behringer DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Manual

Behringer DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Manual

Legendary 2500 series analog envelope generator module for eurorack

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15

Quick Links

Quick Start Guide
DUAL ENVELOPE GENERATOR MODULE 1033
Legendary 2500 Series Analog Envelope Generator Module for Eurorack
V 3.0

Advertisement

loading
Need help?

Need help?

Do you have a question about the DUAL ENVELOPE GENERATOR MODULE 1033 and is the answer not in the manual?

Questions and answers

Summary of Contents for Behringer DUAL ENVELOPE GENERATOR MODULE 1033

  • Page 1 Quick Start Guide DUAL ENVELOPE GENERATOR MODULE 1033 Legendary 2500 Series Analog Envelope Generator Module for Eurorack V 3.0...
  • Page 2 Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, déplacement de la Geräte-Kombination ein 4. Do not block any ventilation openings. Install in vuelco al mover la TC Helicon, Behringer, Bugera, Aston Microphones e combinaison chariot/ Umkippen zu vermeiden. accordance with the manufacturer’ s instructions. combinación carro/...
  • Page 3 Tannoy Turbosound TC Electronic sig på någon beskrivning, fotografi eller uttalande som 、 、 、 保修条款 TC Helicon, Behringer, Bugera, Aston Microphones i TC Helicon Behringer Bugera Aston Microphones finns här. Tekniska specifikationer, utseenden och annan および は Coolaudio są znakami towarowymi lub zastrzeżonymi...
  • Page 4 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Power Connection DUAL ENVELOPE GENERATOR MODULE 1033 Controls 7. TRIGGER MODE – Selects between single mode, where only the gate signal (1) (2) controls the envelope, or multiple mode, which uses a positive trigger pulse to Red Stripe re-trigger the envelope while a gate signal is present.
  • Page 5 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Conexión Eléctrica DUAL ENVELOPE GENERATOR MODULE 1033 Controles 7. TRIGGER MODE – Selecciona entre modo único, donde solo la señal de la (1) (2) puerta controla la envolvente, o modo múltiple, que utiliza un pulso de disparo Red Stripe positivo para volver a disparar la envolvente mientras hay una señal de puerta.
  • Page 6 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Connexion Électrique DUAL ENVELOPE GENERATOR MODULE 1033 Réglages 7. TRIGGER MODE – Sélectionne entre le mode unique, où seul le signal de (1) (2) gate contrôle l’enveloppe, ou mode multiple, qui utilise une impulsion de Red Stripe déclenchement positive pour re-déclencher l’enveloppe lorsqu’un signal de...
  • Page 7 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Netzanschluss DUAL ENVELOPE GENERATOR MODULE 1033 Bedienelemente Red Stripe 7. TRIGGER MODE – Wählt zwischen Einzelmodus, wo nur das Gate-Signal die (1) (2) Hüllkurve steuert, oder Mehrfachmodus, der einen positiven Triggerimpuls verwendet, um die Hüllkurve erneut auszulösen, während ein Gate-Signal vorhanden ist.
  • Page 8 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Conexão de Força DUAL ENVELOPE GENERATOR MODULE 1033 Controles 7. TRIGGER MODE – Seleciona entre o modo único, onde apenas o sinal do portão (1) (2) controla o envelope, ou modo múltiplo, que usa um pulso de disparo positivo Red Stripe para disparar novamente o envelope enquanto um sinal de porta está presente.
  • Page 9 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Connessione di Alimentazione DUAL ENVELOPE GENERATOR MODULE 1033 Controlli 7. TRIGGER MODE – Seleziona tra modalità singola, dove solo il segnale di gate (1) (2) controlla l’inviluppo, o modalità multipla, che utilizza un impulso di trigger Red Stripe positivo per riattivare l’inviluppo mentre è...
  • Page 10 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Stroomaansluiting DUAL ENVELOPE GENERATOR MODULE 1033 Bediening 7. TRIGGER MODE – Selecteert tussen enkele modus, waar alleen het (1) (2) poortsignaal de envelop bestuurt, of meervoudige modus, die een positieve Red Stripe triggerpuls gebruikt om de envelop opnieuw te triggeren terwijl een poortsignaal aanwezig is.
  • Page 11 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Strömanslutning DUAL ENVELOPE GENERATOR MODULE 1033 Kontroller 7. TRIGGER MODE – Väljer mellan enkelläge, där endast grindsignalen styr (1) (2) kuvertet, eller flera lägen, som använder en positiv triggerpuls för att återutlösa Red Stripe kuvertet medan en grindsignal är närvarande.
  • Page 12 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Podłączenie Zasilania DUAL ENVELOPE GENERATOR MODULE 1033 Sterowanica 7. TRIGGER MODE – Wybiera pomiędzy trybem pojedynczym, gdzie tylko sygnał (1) (2) bramki kontroluje obwiednię, lub tryb wielokrotny, który wykorzystuje dodatni Red Stripe impuls wyzwalający do ponownego wyzwolenia obwiedni, gdy obecny jest...
  • Page 13 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide 電源接続 DUAL ENVELOPE GENERATOR MODULE 1033 コントロール シングルモードから選択します。 ゲート信号のみ 7. TRIGGER MODE – (1) (2) がエンベロープを制御します。 またはマルチモード。 ゲート信号 Red Stripe が存在する間、 正のトリガーパルスを使用してエンベロープを再 トリガーします。 長押しして開始しますエンベロープサイクル。 8. MANUAL GATE – ト信号を接続してエンベロープサイクルを制御します。 9. GATE –...
  • Page 14 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide DUAL ENVELOPE GENERATOR MODULE 1033 控制 电源连接 7. TRIGGER MODE – 在单模式之间选择, 只有门信号控制包络, 或多 (1) (2) 重模式, 在出现门控信号时使用正触发脉冲重新触发包络。 Red Stripe 8. MANUAL GATE – 按住以启动包络周期。 9. GATE– 连接门信号以控制包络周期。 10. TRIG – 如果还存在门信号, 则触发对信封的新攻击。...
  • Page 15 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide Specifications 技术参数 Inputs 输入 Gate 门 类型 3.5 mm TS Type 3.5 mm TS jack, DC coupled 插孔, 直流耦合 阻抗 >35 kΩ Impedance >35 kΩ 最小门限 +4 V Gate threshold +4 V 最大输入电平...
  • Page 16 DUAL ENVELOPE GENERATOR MODULE 1033 Quick Start Guide FEDERAL COMMUNICATIONS Correct disposal of this product: This symbol indicates that this product must not be disposed of with household waste, COMMISSION COMPLIANCE according to the WEEE Directive (2012/19/EU) and your national law. This product should be taken to a collection...
  • Page 17 We Hear You...