Download Print this page
SIP Fireball RP15 Manual

SIP Fireball RP15 Manual

Radiant propane heater

Advertisement

Quick Links

SIP Industrial Products
Limited Gelders Hall Road
Shepshed
Loughborough
Leicestershire
LE12 9NH
United Kingdom
For help or advice please contact
your distributor, or sip directly on:
Tel.: 01509 500400
Email:
sales@sip-group.com
or
customerservice@sip-group.com
www.sip-group.com
Fireball RP15 Radiant
Propane Heater
Please read and fully understand the instructions in this manual
before operation. Keep this manual safe for future reference.
SIP Code 09314

Advertisement

loading
Need help?

Need help?

Do you have a question about the Fireball RP15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIP Fireball RP15

  • Page 1 Leicestershire LE12 9NH Fireball RP15 Radiant United Kingdom Propane Heater For help or advice please contact your distributor, or sip directly on: Tel.: 01509 500400 Email: sales@sip-group.com SIP Code 09314 customerservice@sip-group.com Please read and fully understand the instructions in this manual www.sip-group.com...
  • Page 2 INTRODUCTION Thank you for purchasing this SIP Radiant heater. This portable gas radiant heater is designed to give safe, efficient and reliable operation and is for use with Propane Gas only. Propane gas bottles are readily available from builders merchants or gas suppliers.
  • Page 3 SAFETY INSTRUCTIONS 10. This heater is for indoor use only in Read and ensure you fully well ventilated areas. understand the following precautions and the hazards associated with this 11. If at any time, gas odour is type of equipment. detected, IMMEDIATELY STOP 1.
  • Page 4 FRESH AIR REQUIREMENTS • DO NOT use in unventilated areas. • The flow of combustion and ventilation air must not be obstructed. WARNING: PROVIDE AT LEAST A 3FT OPENING OF FRESH, OUTSIDE AIR WHILST USING THIS HEATER. IF FRESH OUTSIDE AIR VENTILATION IS NOT PROVIDED, CARBON MONOXIDE POISONING CAN OCCUR.
  • Page 5 IF YOU SMELL GAS NO ODOUR DETECTED Liquid Propane gas has a man-made odourant added specifically for detection 1. Some people cannot smell the odour of gas leaks. added to propane (LP). You must If a leak occurs you should be able to determine if you can smell the smell the gas.
  • Page 6 FEATURES OF THE 09314 RP15 Radiant Heater Understanding the basic operation of the heater will reinforce the need to maintain it in top condition at all times whilst always observing the safety precautions. The heater comprises of three basic systems: 1.
  • Page 7 Remove the heater from the carton and remove all protective material used for shipment. Check the heater for possible shipping damage. Should any damage be apparent, please notify your SIP dealer immediately. ASSEMBLING THE SUPPORT STAND 1. Connect the stand base section to the upper part and secure with the wing nut supplied.
  • Page 8 GAS CONNECTION WARNING: PROPANE GAS CYLINDERS MUST BE USED AND STORED IN ACCORDANCE WITH THE ‘HIGHLY FLAMMABLE LIQUIDS AND LIQUEFIED PETROLEUM GASES REGULATIONS 1972. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
  • Page 9 4. Place the regulator on the cylinder connection and hand tighten by turning anti-clockwise. 5. Tighten firmly using a gas spanner (or an adjustable spanner), continuing in an anti-clockwise direction. 6. Simply turn the valve hand wheel anti-clockwise when you need to start the flow of gas.
  • Page 10 OPERATION WARNING: BEFORE STARTING THE HEATER YOU MUST ENSURE THAT THE MINIMUM VENTILATION REQUIREMENTS ARE OBSERVED TO AVOID THE RISK OF CARBON MONOXIDE POISONING. WARNING: THIS HEATER WILL BE HOT DURING NORMAL OPERATION. AVOID PHYSICAL CONTACT. DO NOT ALLOW CLOTHING OR OTHER COMBUSTIBLE MATERIALS TO TOUCH THE HEATER.
  • Page 11 WARNING: DO NOT FACE THE HEATER ELEMENT WHEN STARTING - ALWAYS STAND TO ONE SIDE. NOTE: If a new gas cylinder has been connected, it may take time for the gas line to be purged of air. Press the Piezo electric button every 10-15 seconds until it ignites.
  • Page 12 TROUBLESHOOTING Fault Cause Remedy Burner fails to light 1.Gas supply valve 1.Open gas supply valve closed. slowly 2.Excess gas flow 2.Close propane supply valve at propane tank and re- open slowly. 3.Piezo ignition not 3.Check wire lead for sparking. damage. Replace igniter assembly.
  • Page 13 5. If the hose shows evidence of excessive abrasion or wear or if the hose is cut it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be as supplied by SIP International. 6. The heater, including hose and regulator assembly, must be inspected at least annually by a qualified service person.
  • Page 14 COMPONENT PARTS Guard assembly Piezo igniter kit Thermocouple protector Hose/regulator assembly Reflector assembly On/off Knob Ignitor electrode Inlet connection Rear guard assembly On/off valve Tip-over switch Tube support Wing nut Thermocouple Tube base Bolt End cap Gas valve...
  • Page 15 DECLARATION OF CONFORMITY...
  • Page 16 This will allow the recycling of raw materials and help protect the environment. For help or advice please contact your distributor, or sip directly on: Tel.: 01509 500400 Email: sales@sip-group.com customerservice@sip-group.com www.sip-group.com...

This manual is also suitable for:

09314