D15RE05 RANGE /h - 5 US GPM Congratulations on your new Dosatron. Please read the following important information. SYSD15RE05 Practical operating 100 l/h Mini - 1000 l/h Maxi flow range: [0.5 US GPM - 5 US GPM ] Operating pressure: bar 2.5 - 6...
Page 2
- In a case where the water installation is higher than the DOSATRON itself, there is a possible risk of water and concentrate flowing back through the DOSATRON. In this case, installing a non-return valve downstream is recommended.
Page 3
- It is the responsibility of the owner/operator to check that the flow and pressure of the installation do not exceed the DOSATRON characteristics. - Adjustmentmust be made when there is no pressure in the Dosatron. Turn off the water supply and allow the pressure to drop to zero.
Page 4
Max. Torque 20 Nm Maximum: 19 clicks/15 sec. Valve Check Valve FILTER 300 mesh [60 microns] Depending on your water quality WHAT YOU SHOULD DO WHAT YOU SHOULD NOT DO When possible, DO NOT PLACE the container directly under the DOSATRON NO !
Page 5
CAUTION - When connecting a DOSATRON either to the public water supply or to its own water source, you must respect the regulations in force concerning protection of the source i.e. backflow prevention, etc. - Contact local authorities for requirements of backflow prevention.