Download Print this page
M&C HEX5-1.08 Instruction Manual

M&C HEX5-1.08 Instruction Manual

Regulated ex-heater with internal controller, with external controller
Hide thumbs Also See for HEX5-1.08:

Advertisement

Quick Links

Regulated Ex-Heater
HEX5-1.08 with internal controller,
HEX5-2.08 with external controller
II 3 G
II 3 D
Instruction Manual
Version 1.03.00

Advertisement

loading
Need help?

Need help?

Do you have a question about the HEX5-1.08 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for M&C HEX5-1.08

  • Page 1 Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.03.00...
  • Page 2 With the release of this version all older manual versions will no longer be valid. The German instruction manual is the original instruction manual. In case of arbitration only the German wording shall be valid and binding. Version: 1.03.00 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 3 Electrical connection HEX 5-1.08 ................................13 Figure 4 Electrical connection HEX 5-2.08 ................................13 Figure 5 Example Heater HEX5-1.08 on gas sample probe SP3200 ....................14 Figure 6 Overview risk assessment ..................................17 Figure 7 Connection Diagram HEX 5-1.08................................20 Figure 8 Connection Diagram HEX 5-2.08................................
  • Page 4 The requirements of the RoHS2 (‘Restriction of Hazardous Substances 2’) directive 2011/65/EU and its annexes are met. Declaration of conformity The EU Declaration of conformity can be downloaded from the M&C homepage or directly requested from M&C. HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 5 4 and chapter 8 of these operating instructions. Refrain from any use other than for this purpose. Improper use can lead to serious injury, see the safety instructions at the appropriate place. www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 6 M&C, please be sure that it is properly packaged and shipped with protective packaging. The repaired or replaced device will be shipped free of delivery charges to the point of use. HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 7 These are important information about the product or parts of the instruction manual referring to operating in hazardous areas. High voltages! Protect yourself and others against damage which might be caused by high voltages. Hot surface! Contact may cause burn! Do not touch! www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 8 The contact is closed and the Indicator on controller K1 is “AN” (ON), when the heater has reached the operating temperature. Indicator K3 shows that the heater is activated. HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 9 The product label with the serial number is located on the top of the temperature controller. Please refer to this serial number if you have any questions about your device or if you need to order spare parts or consumables. www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 10 5 °C [9 °F] higher than T manual Reset Ex Standards IEC 60079-0: 2011 Ed.6 EN 60079-0:2012 + A11:2013 IEC 60079-7: 2015 Ed.5 EN 60079-7:2007 IEC 60079-15: 2010 Ed.4 EN 60079-18:2009 IEC 60079-31: 2013 Ed.2 EN 60079-31:2014 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 11 The mounting dimensions are shown in figure 2. • In case of the externally mounted temperature regulator, the maximum ambient temperature of the heater connection box that is allowed is +70°C [158 °F]. www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 12 Depending on the ambient temperature at the mounting location, the cables used for the wiring must be temperature resistant according to requirement. • Connect the housing of the temperature controller, and if applicable the electrical connection box of the HEX5.2-08, to earth (equipotential bonding). HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 13 Electrical connections electric heater HEX 5-1.08 Figure 3 Electrical connection HEX 5-1.08 Electrical connections electric heater HEX 5-2.08 Figure 4 Electrical connection HEX 5-2.08 www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 14 60 °C [140 °F]. Figure 5 Example Heater HEX5-1.08 on gas sample probe SP3200 The heating up is regulated to 1.5 °C/min [2.7 °F per minute] by default via a programmed temperature ramp. The total time of heating up is approx.
  • Page 15 M&C protected against unauthorized access. A Danger wire strap on the terminal strip X1/5 protects against unauthorized access. The programming of the temperature class affects the complete heater and can only be modified by M&C personnel. www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 16 The product complies with the current regulations according to state-of-the-art science and technology. Nevertheless, not all sources of danger can be eliminated while observing technical protective measures. Therefore, the following risk assessment and the description of exposure hazards refer to the work steps mentioned above. HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 17 Chemical burns due to aggressive media possible! This applies to all liquids in vessels and in the product. In general, for electrical and mechanical work on the product, wear personal protective equipment (PPE) in accordance with the risk assessment. www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 18 The product can be transported by 1 to 2 person(s). The instructions for appropriate personal protective equipment (PPE) must be observed. The weight specifications are contained in the technical data of this product. Furthermore, the work safety regulations of the operator must be observed. HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 19 Connection diagrams • Type Examination Certificate • Type Examination Certificate Supplement 1 • CSA- Certificate of Compliance • IECEx Certificate of Conformity For additional manuals and data sheets please look on our home page www.mc-techgroup.com www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 20 Figure 7 Connection Diagram HEX 5-1.08 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 21 Figure 8 Connection Diagram HEX 5-2.08 www.mc-techgroup.com HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 22 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 23 HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 24 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 25 HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 26 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 27 HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 28 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 29 HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 30 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 31 HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 32 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 33 HEX5-1.08, HEX5-2.08 | 1.03.00...
  • Page 34 HEX5-1.08, HEX5-2.08 | 1.03.00 www.mc-techgroup.com...
  • Page 35 HEX5-1.08, HEX5-2.08 | 1.03.00...

This manual is also suitable for:

Hex5-2.0820s965020s965520s9650a20s9655a