WARNINGS This manual is dedicated to the technical personnel responsible of the installation, management and maintenance of the plants. The manufacturer assumes no responsibility for damages or malfunctions occurring after intervention by non-authorized personnel, or not compliant with the prescribed instructions. Before performing any maintenance or repair action, ensure that the system is electrically and hydraulically insulated.
Page 3
TABLE OF CONTENTS PACKING LIST ............................ 4 INTRODUCTION ..........................4 INSTALLATION ........................... 4 TECHNICAL DATA ..........................5 FUNCTIONAL DESCRIPTION OF THE SYSTEM ................6 ELECTRICAL CONNECTIONS ......................9 START-UP ............................11 VISUALIZATIONS ..........................11 OPERATION OF THE ELECTRONIC UNIT ..................11 Standard Configuration ......................
Page 4
8. Instruction manual INTRODUCTION EF300 is a compact system easy to install (wall) and maintain, which allows to monitor and control the pH and chlorine levels in swimming pools. The EF300 system includes a digital controller which operates accordingly with the set thresholds, pH electrode, temperature probe, chlorine cell and down-flow type probe-holder.
Page 5
TECHNICAL DATA pH Input available on BNC connector, input impedance > 10^12 Ω Chlorine Input available on M8 connector, for CAC cell Temperature Input prewired input for PT100 sensor Measure Ranges 0.00 to 14.00 pH, 0.00 to 5.00 ppm chlorine, 0 to 100°C Precision better than 1% of the full scale Repeatability...
Page 6
FUNCTIONAL DESCRIPTION OF THE SYSTEM Front view Control panel with large display and keyboard (see details on next page) 3-wire micro-magnetic flow sensor (prewired) Down-flow type probe-holder with transparent methacrylate body and flow regulator PT100 temperature probe pH electrode with direct cable and BNC with protective sheath CAC-CLO-M1 cell for free chlorine measurement Bottom view: connections POWER...
Page 7
Front panel POWER LED Green light: slow flashing indicates that the unit is powered and normally functioning, while fast blinking indicates a fault (lack of liquid to be dosed or pump disabled) LED PUMP1, 2 Red light is on when the corresponding pump is dosing CAL Key Provides access to the “Configuration”, “Calibration”...
Page 9
ELECTRICAL CONNECTIONS The EF300 unit is supplied internally prewired and complete with power cable. Standard power supply: 230 V∼, 50 Hz, monophasic. Carefully follow all the rules of electrical safety. Before starting the unit, check that all electrical and plumbing connections have been properly executed.
Page 10
Internal Connections (for technical personnel only) The unit is provided internally prewired, and all connections of normal use (power supply, dosing pumps, measurement sensors and flow sensor) are available externally via cable or connector. However, if you need to operate on the electronic boards or replace blown fuses, refer to the diagram below.
Page 11
START-UP At start-up the microcontroller displays for a couple of seconds information about the firmware (type / version), then shows the two measures flashing for all the start-up delay time (if set) and then starts operating accordingly with the configured working mode. VISUALIZATIONS During normal operations, the display shows the two measured values on the top line, while the bottom row switches between the temperature measurement and the status of the two pumps.
Page 12
Standard Configuration The standard configuration mode allows the customer to set a series of parameters related to the normal functioning of the unit. These parameters can be freely accessed and configured from the front keyboard. Once selected the “Standard Configuration” S T A N D A R D C O N F I G .
Page 13
Default PAR. Description Min Value Max Value Set Value Value Autoset Password Alarm Functioning Relay NO / Relay NC Relay NO Flow Functioning Input NO / Input NC Input NO pH Equilibrium 0min 240min 0min Warning! The complete list of parameters can be accessed only from the “Advanced Configuration” menu, while the “Standard Configuration”...
Page 14
measurement returns to an acceptable. If measurement remains outside of the setpoint for a time longer than that set, an alarm is generated, the display shows the message “Al.1” and the pump stops dosing. To reset the alarm and resume to normal operations, press the ON/OFF button or shutdown and restart the unit.
Page 15
Notes: • Once in configuration mode, if no button is pressed for 30 seconds, the unit automatically returns to the idle mode. • The system is factory configured with default values; you can delete undesired settings and restore the initial configuration, using the “AUTOSET” function (P15). Electrochemical Calibration pH Calibration Rinse the pH electrode with distilled water, then immerse it in the pH 7.01 pH buffer solution.
Page 16
Calibration of the CAC-CLO-M1 Cell To calibrate the cell, a colorimeter for measuring the chlorine concentration in aqueous solutions is needed (for example with DPD1 method). Run instrument and cell for at least 6 hours with chlorinated water, containing an average chlorine working concentration.
Page 17
Manual Mode At any time, you can force a manual working mode, useful for a temporary use of the system. If a password has been set (see parameter P16), the system will require it to enable the access to this feature.
Page 18
CAC-CLO-M1 CELL The supplied cell measures the organic free chlorine concentration in water and is provided complete with a spare electrolyte bottle. The CAC-CLO cells are membrane covered, amperometric, 2-electrode sensors, with the electrodes immersed in a specific electrolyte. They allow to determine the concentration in water of available chlorine.
Page 19
Legend Electrolyte bottle Membrane-cap Nozzle Vent hole L. Electrolyte filling level Important Notes To avoid measurement errors, the membrane-cap must be correctly screwed till the stop (see picture). The electrolyte easily oxidizes with air. After use, always keep the bottle closed. Do not transfer to other containers.
Page 20
Cell Wiring The cell is provided with a 4-wire (signal + power supply), shielded, direct cable. For connection to the terminal block, please refer to the instruction manual of the electronic unit and follow the below colour code: brown wire = -5V white wire = IN...
Page 21
CONTROL EXAMPLES Typical application in swimming pool control: acidification when pH exceeds the pH value of 7.30. Refer to the “List of configuration parameters” and set: P01 ON/OFF working mode for pump 1 P02 set point 7.30 pH P04 ...
Page 22
STEIEL provides a kit of solutions for the cleaning and storage of pH and redox electrodes. The kit includes three solutions:...
Page 23
3-wire, PNP, flow sensor for CLE12 and SD series probe-holders, for SD-SF/PNP 54500009 connection to instruments S507 / S508 / EF300 / EF315 SLP2 level sensor with 2 m cable and connector 97009002...