Advertisement

Quick Links

EF260 Series
Model EF267
INSTRUCTION MANUAL
STEIEL Elettronica S.r.l. – Viale Europa, 24 – 35020 Ponte San Nicolò – PADOVA - ITALY
Tel. +39 049.8961488 – Fax +39 049.8960184 – www.steiel.it – info@steiel.it
Certified Company, according to UNI EN ISO 9001 standards

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EF260 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Steiel EF260 Series

  • Page 1 Model EF267 INSTRUCTION MANUAL STEIEL Elettronica S.r.l. – Viale Europa, 24 – 35020 Ponte San Nicolò – PADOVA - ITALY Tel. +39 049.8961488 – Fax +39 049.8960184 – www.steiel.it – info@steiel.it Certified Company, according to UNI EN ISO 9001 standards...
  • Page 2 WARNINGS This manual is dedicated to the technical personnel responsible of the installation, management and maintenance of the plants. The manufacturer assumes no responsibility for damages or malfunctions occurring after intervention by non-authorized personnel, or not compliant with the prescribed instructions. Before performing any maintenance or repair action, ensure that the system is electrically and hydraulically insulated.
  • Page 3 The manufacturer can modify the instrument or the technical manual without advanced notice. Warranty All our products are warranted for a period of 12 months from the delivery date. Warranty is not valid if all instructions of installation, maintenance and use, are not strictly followed by the user. Local regulations and applicable standards have also to be followed.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS PACKING LIST ............................ 5 INTRODUCTION ..........................5 INSTALLATION ........................... 5 TECHNICAL DATA ..........................6 FUNCTIONAL DESCRIPTION OF THE SYSTEM ................7 HYDRAULIC CONNECTIONS ......................9 Suction Line ..........................9 Bleed Line ..........................9 Injection Line ......................... 10 PRIMING ............................
  • Page 5: Packing List

    PACKING LIST The EF267 unit is supplied prewired and complete with: 1. pH electrode with short glass body, 65 cm cable and BNC connector with protection 2. Redox electrode with short glass body, platinum sensor, 65 cm cable and BNC connector with protection (Note: redox electrode with gold sensor is also available upon request) 3.
  • Page 6: Technical Data

    TECHNICAL DATA pH/RX Inputs available on BNC connectors, input impedance > 10^12 Measure Ranges 0.00 to 14.00 pH, 0 to 1000 mV (redox), 0 to 100° C (optional, to be requested upon order) Precision / Repeatability better than 1% of the full scale / better than 0.2% of the full scale Configuration two configuration level (standard and advanced) LEV Input...
  • Page 7: Functional Description Of The System

    FUNCTIONAL DESCRIPTION OF THE SYSTEM Front View • Control panel with large display and keyboard (see description on next page) • Electromagnetic pump for acid dosage • Down-flow type electrode-holder with transparent methacrylate body Bottom View: Connections POWER Power cable (prewired) LEV pH Level sensor connector for acid pump / tank FLOW...
  • Page 8 Front Panel POWER LED Green light; slow flashing indicates that the unit is powered and normally functioning, while fast blinking indicates a fault (lack of liquid to be dosed or pump magnet disabled) LED OUT1 Red light; lights at each pulse of the corresponding pump magnet LED OUT2 Red light on when the consent for the chlorine regulation device is active CAL Key...
  • Page 9: Hydraulic Connections

    HYDRAULIC CONNECTIONS Check that the suction line does not exceed the maximum height of 1.5 m from the tank bottom. Unscrew the pipe-wrench nut and remove the two protective caps from fittings (in the case a pump head needs to be removed, it is recommended to reuse the protective caps, to prevent any leakage from the pump body).
  • Page 10: Injection Line

    Injection Line (also see drawing on the previous page) 1. Unscrew the fixing nut of the head fitting (located on the top of the pump head) and remove the protective cap. 2. Cut the white, semi-rigid, PE tube. 3. Insert the pipe-wrench and tube-press on the PE tube. 4.
  • Page 11: Electrical Connections

    ELECTRICAL CONNECTIONS The EF267 unit comes prewired and complete with power cable (with plug upon request). Standard power supply: 230 V∼, 50 Hz, monophasic. Carefully follow all the rules of electrical safety. Before starting the unit, check that all electrical and plumbing connections have been properly executed.
  • Page 12: Internal Connections (For Technical Personnel Only)

    INTERNAL CONNECTIONS (for technical personnel only) The unit is provided internally prewired, and all connections of normal use (power supply, measurement sensors and level sensors) are available externally via cable or connector. However, if you need to operate on the electronic boards or replace blown fuses, refer to the diagram below.
  • Page 13: Start-Up

    START-UP At start-up the microcontroller displays for a couple of seconds information about the firmware (type / version), then shows the two measures flashing for all the start-up delay time (if set) and then starts operating accordingly with the configured working mode. VISUALIZATIONS During normal operations, the display shows the two measured values on the top line, while the bottom row displays the status of the two pumps.
  • Page 14: Operations Of The Electronic Unit

    OPERATIONS OF THE ELECTRONIC UNIT To access the configuration, calibration and manual mode menus, press the CAL button. The display will show the following available options: • Standard Configuration • Advanced Configuration • Calibration IN1 (input 1) pH • Calibration IN2 (input 2) redox •...
  • Page 15: List Of Configuration Parameters

    List of Configuration Parameters In this section are listed all the configuration parameters. It is recommended to fill the last column with the values set for your application. Default PAR. Description Min Value Max Value Set Value Value Functioning Type P1 ON-OFF / Proportional ON-OFF Setpoint P1...
  • Page 16 PARAMETER 04 DOSAGE P1 This parameter allows to set the dosage direction. The choice depends on the product dosed to adjust the pH level: if you dose an acid, set this parameter to “Acidification”, while if you dose a base set “Alkalinisation”.
  • Page 17 PARAMETER 15 RESTORE DEFAULT VALUES This feature allows to restore the factory configuration if you want to delete incorrect or undesired settings. Once confirmed this option, all custom setting will be lost. To enable the feature, enter the value “12” . PARAMETER 16 PASSWORD This parameter allows to enter a password (numeric value within 1 and 255) to protect the system...
  • Page 18: Electrochemical Calibrations

    Electrochemical Calibrations pH Calibration Rinse the pH electrode with distilled water, then immerse it in the pH 7.01 pH buffer solution Press the CAL key to enter the menu mode I N 1 C A L I B R A T . and use the ⇑...
  • Page 19: Manual Mode

    Redox Calibration 1) Rinse the electrode with distilled water, then immerse it in the calibration solution (e.g. 220 mV) 2) Press the CAL key to enter the menu mode I N 2 C A L I B R A T . and use the ⇑...
  • Page 20: Control Examples

    CONTROL EXAMPLES Typical application in swimming pool control: acidification when pH exceeds the pH value of 7.30. Refer to the “List of configuration parameters” and set: ON/OFF working mode for pump 1 set-point 7.30 pH dosage direction “ACIDIFICATION” if the quantity of the product to be injected is not known, it is recommended to start with a low working frequency (e.g.
  • Page 21: Maintenance

    MAINTENANCE The periodic maintenance operations are essential for the proper functioning of the system and its duration in time. The below advices should be strictly followed. Before any operation, make sure the system is unplugged! Dosing Pump For a perfect seal, after about 800 hours of work, it is recommended to tighten the bolts of the pump by applying a torque of 4 Nm.
  • Page 22: Accessories And Spare Parts

    ACCESSORIES AND SPARE PARTS Item Description Code Combined pH electrode with short glass body, 65 cm cable pH Electrode 8009.3010 and BNC connector Combined redox electrode with short glass body, platinum RX/Pt Electrode 8019.3010 sensor, 65 cm cable and BNC connector Combined pH electrode with short plastic body, 65 cm cable pH Electrode 8009.2231...

This manual is also suitable for:

Ef267

Table of Contents

Save PDF