Page 2
Contents 1. The Basics ..............1 1.1 Safety .............. 1 2. Introduction ..............4 2.1 Intended Use ............. 4 2.2 Contraindications ..........4 2.3 About the Product ..........4 2.4 Symbols ............6 2.5 Unpacking ............8 3. Using the Product ............8 3.1 Charge the Battery ..........
Page 3
1. The Basics This manual contains the instructions necessary to operate the product safely and in accordance with its function and intended use. Observance of this manual is a prerequisite for proper product performance and correct operation and ensures patient and operator safety. 1.1 Safety Warnings and Cautionary Advice Before using the device, please ensure that you have read this...
Page 4
sources of water or fire; or locations that are subject to strong electromagnetic influences. This device displays changes in the pulse rate and blood pressure etc. which may have various different causes. These may be harmless, but may also be triggered by illnesses or diseases of differing degree of severity.
Page 5
limb. Consult your physician before using the monitor if you have severe blood flow problems or blood disorders as cuff inflation can cause bruising. Please prevent that operation of the device results in prolonged impairment of the circulation of the blood of the patient. Do not apply the cuff on an arm with another medical electrical ...
Page 6
1min≤t < 10min. 2. Introduction 2.1 Intended Use The device is intended to measure blood pressure only, electrocardiogram (ECG) only or blood pressure and ECG simultaneously. The device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult population. The device is intended to record, store, and transfer single-channel electrocardiogram(ECG), blood pressure and pulse rate.
Page 8
1 ) Start/Stop button Power On/Off Short press to Start/Stop measuring blood pressure. 2 ) Function button Short press to start the ECG measurement. Press and hold for 2 seconds to review historical data. Short press to review historical data. (for models without ECG ...
Page 9
2.5 Symbols Symbol Meaning Manufacturer Date of manufacture Serial number In conformity with Directive 93/42/EEC Against ingress of solid foreign objects ≥12.5mm IP22 diameter, Against dripping(15° tilted) Follow operating instructions Application part type BF Warning MRI unsafe. Presents hazards in all MR environments as device contains strongly ferromagnetic materials.
Page 10
2.5 Unpacking Main Unit; Cuff; Air Hose; Charging Cable; User Manual 3. Using the Product 3.1 Charge the Battery Use the USB cable to charge the monitor. Connect the USB cable to a USB charger or to the PC. It takes 2-3 hours to fully charge. When the battery is fully charged, the indicator will be off.
Page 11
3.2.2 Applying the Arm Cuff 1) Wrap the cuff around the upper arm, about 1 to 2 cm above the inside of the elbow, as shown. 2) Place the cuff directly against the skin, as clothing may cause a faint pulse and result in a measurement error.
Page 12
measurement. Note 1: During the measurement, you should keep still and don’t squeeze the cuff. Stop measuring when the pressure result appear in the product. Otherwise the measurement may be effected and the blood pressure readings may be inaccurate. Note 2: Max. Temperature of the cuff in contact with the patient does not exceed 48°C, and skin surface contact, duration is less than 1 h.
Page 13
If the ECG electrodes are dirty, remove the dirt using a soft cloth or cotton swap dampened with disinfection alcohol. While taking measurements, do not touch your body with the hand with which you are taking measurements. Please note that there must be no skin to skin contact between your ...
Page 14
The recording must take at least 30 seconds to complete, and to be analyzed by the detectors You can get different signal amplitudes from different methods. Use Lead II mode if the signal is too low in Lead I mode. 3.3.3 Turn on/off Heartbeat Sound The buzzer beeps when a heartbeat is detected while recording ECG.
Page 15
The product don’t The product is running Reset the device by response to the in an unexpected status. press and hold the button press. button for 8s. Cannot get blood The measurement is Keep arm still and pressure readings. interrupted by arm don’t squeeze the movement or bulb during...
Page 16
Wireless connectivity Bluetooth 5.2 BLE Wifi 2.4G LTE CAT1 Power Supply Charge input USB Type-C, DC 5V Battery type Rechargeable lithium-polymer battery Charge time 2 hours Blood Pressure Measurements Technology Oscillometric Method Pressure measurement 0 – 300 mmHg range Pressure measurement ±3 mmHg accuracy Pulse rate range...
Page 17
ECG bandwidth 0.67 ~40 HZ Gain Accuracy Maximum amplitude error ±10% Heart Rate Calculation Divide 1 minute by the number of squares between two R waves. Storage 30 records Bluetooth RF Frequency range 2.400GHz-2.483GHz Wifi Frequency range 2.400GHz-2.483GHz Frequency range LTE-FDD B1/B3/B5/B7/B8/B20/B28 LTE-TDD B38/B40/B41 Expected service life...
Page 18
invalid! 6.2 Cleaning The device can be repeatedly used. Please clean before reuse as follow: • Clean the device with a soft, dry cloth with 70% alcohol. • Do not use petrol, thinners or similar solvent. • Clean the cuff carefully with cloth soaked 70% alcohol. •...
Page 19
8. Electromagnetic Compatibility The device meets the requirements of EN 60601-1-2. Warnings and Cautionary Advice Using accessories other than those specified in this manual may result in increased electromagnetic emission or decreased electromagnetic immunity of the equipment. The device or its components should not be used adjacent to or ...
Page 20
Harmonic emissions domestic establishments and those IEC61000-3-2 applicable directly connected to the public low-voltage power supply network that Voltage Fluctuations supplies buildings used for domestic / Flicker Emissions applicable IEC 61000-3-3 purposes. Guidance & Declaration — electromagnetic immunity The Blood Pressure Monitor is intended for use in the electromagnetic environment specified below.
Page 21
the Electronic for 25/30 Stethoscope be cycles powered from an uninterruptible <5% U power supply or a (>95% dip in battery. for 5/6 sec Power frequency (50/60 HZ) 30 A/m 30 A/m magnetic field IEC Power frequency 61000-4-8 magnetic fields/ CW 8A/m for CW 8A/m for Proximity magnetic...
Page 22
60601-1- performance of 2:2014+A1:2020) 2:2014+A1:2020) this equipment could result. Shenzhen Viatom Technology Co., Ltd. 4E,Building 3, Tingwei Industrial Park, No.6 Liufang Road, Block 67, Xin’an Street, Baoan District, Shenzhen 518101 Guangdong China MedNet EC-REP GmbH Borkstrasse 10, 48163 Muenster, Germany...