Homedics Walgreens 518728 Manual

IMPORTANT PRODUCT NOTICES AND SAFETY INSTRUCTIONS

When using your blood pressure monitor, basic precautions should always be followed. Please read and follow all instructions and warnings before using this product. Save these instructions for future reference.

  • Please note that this is a home healthcare product only and it is not intended to serve as a substitute for the advice of a physician or medical professional.
  • Do not use this device for diagnosis or treatment of any health problem or disease. Measurement results are for reference only. Consult a healthcare professional for interpretation of pressure measurements. Contact your physician if you have or suspect any medical problem. Do not change your medications without the advice of your physician or healthcare professional.
  • This product is not suitable for people with arrythmias. This device may have difficulty determining the proper blood pressure for individuals with diabetes, poor circulation of blood, kidney problems or for users who have suffered from a stroke.
  • Consult your physician before measuring blood pressure at the wrist if you have any of the following conditions: Severe hypertension, severe diabetes, severe arteriosclerosis, severe kidney disease or vascular disease that may compromise circulation.
  • The pulse display is not suitable for checking the frequency of heart pacemakers.
  • Electromagnetic interference: The device contains sensitive electronic components. Avoid strong electrical or electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave ovens). These may lead to temporary impairment of measurement accuracy.
  • Use blood pressure monitor only for its intended use.
  • Do not wrap the cuff around body parts ot her than your wrist.
  • This unit is intended for use in measuring the blood pressure and pulse rate of adults. Do not use this device on infants or those who cannot express their own consent. This unit should not be operated by children.
  • Use only 1.5V AAA alkaline batteries for power supply.

Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope ausculatory method, within the limits prescribed by the American National Standard, Manual, electronic, or automated sphygmomanometers.

ABOUT BLOOD PRESSURE

What is Blood Pressure?

Blood pressure is the pressure exerted on the artery walls while blood flows through the arteries. The pressure measured when the heart contracts and sends blood out of the heart is systolic (highest) blood pressure. The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic (lowest) blood pressure.

Why Measure Your Blood Pressure?

Among today's various health problems, those associated with high blood pressure are very common. High blood pressure dangerously correlates with cardiovascular diseases. Therefore, blood pressure monitoring is important for identifying those at risk.

BLOOD PRESSURE STANDARD

The U.S.Department of Health and Human Services and the National Institutes of Health have developed a blood pressure standard that identifies areas of low- and high-risk blood pressure. This standard, however, is a general guideline as blood pressure varies among different people, age groups, etc.

Categories for Blood Pressure Levels in Adults

Systolic (mmHg) Diastolic (mmHg)
Stage 2 Hypertension ≥160 ≥100
Stage 1 Hypertension 140~159 90~99
Prehypertension 120~139 80~89
Normal <120 <80

For adults 18 and older who are not on medicine for high blood pressure, are not having a short-term serious illness, and do not have other conditions, such as diabetes and kidney disease.

To determine category of risk when systolic and diastolic readings fall into two areas, use the higher of the two numbers for classification.

There is an exception to the above definition of high blood pressure for people with diabetes and chronic kidney disease. A blood pressure of 130/80 mmHg or higher is considered high blood pressure for those individuals.

This monitor comes equipped with a Risk Category Indicator to visually indicate the assumed risk level of each reading based upon these standards. See "Risk Category Indicator" for more information on this feature.

It is important that you consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk. For reliable monitoring and reference of blood pressure, keeping long-term records is recommended.

HOW THIS BLOOD PRESSURE MONITOR WORKS

This monitor uses Smart Measure™ technology to detect your blood pressure. With one touch of a button, the cuff will automatically inflate to block the blood flow through your artery. Next, the deflation process starts. Smart Measure™ technology enables the monitor to automatically inflate and deflate to the appropriate level for each individual. Please note that any muscle movement during inflation or deflation will cause measurement error. When measurement is complete, the monitor will display your systolic pressure, diastolic pressure, and pulse readings.

Based upon your measurement results, the monitor's Risk Category Indicator will alert you if your reading falls into the pre-hypertension, stage 1 hypertension, or stage 2 hypertension categories. See "Risk Category Indicator" for more information on the Risk Category Indicator.

NAME/FUNCTION OF EACH PART

NAME/FUNCTION OF EACH PART

Accessories for unit

2 "AAA" size, 1.5V alkaline batteries included in the carrying case with the unit.

DISPLAY EXPLANATIONS

DISPLAY EXPLANATIONS

Display Symbols

User 1: Appears when the monitor is operated by User 1.
User 2: Appears when the monitor is operated by User 2.
Weak Battery Symbol: Appears when batteries should be replaced.
Pulse Symbol: Shows the pulse rate per minute.
Memory Average: Displays average of last 3 readings
Risk Category Indicator: Compares readings against blood pressure guidelines. See "Risk Category Indicator" for more information.

If and any of the following letters and numbers appear in the area that systolic pressure should be displayed, an error has occurred with your reading. See Troubleshooting section of this manual for more information.

Measurement Error: Measure again. Wrap the cuff correctly and keep wrist steady during measurement.
Air Circuit Abnormality: Measure again.
Pressure Exceeding 300 mmHg: Switch the unit off to clear, then measure again.
Error Determining Measurement Data: Measure again.
Recalibration Alert: Recalibration recommended.
See "Recalibration Service" for information.

INSTALLING BATTERIES

  1. The battery cover is located along the top side of the monitor. Remove battery cover by pressing in on sides and pulling away from the monitor.
  2. Install upper battery first according to the polarity indications inside the compartment. This battery should be in the bottom position as shown in figure 2.

    Battery Type: 2 Alkaline LR03 (AAA) size
  3. Place in the other battery, according to the polarity indications inside the compartment and as shown in figure 3.
  4. Replace the cover by inserting it back into place.

Replace the batteries if

  1. The weak battery symbol appears in the display.
  2. Nothing appears in the display when the power is switched on.

As the supplied batteries are for test only, they may be discharged earlier than batteries you buy in stores. Replace the batteries in pairs. Use only 1.5V AAA alkaline batteries. Remove batteries when unit is not in use for extended periods of time.

warning Note: Batteries are hazardous waste. Do not dispose of them together with the household garbage.

DATE & TIME SET PROCEDURE

  1. To adjust the date/time, press the Set button located on the side of the monitor. The display will show a blinking number showing the month.
  2. Change the month by pressing the button. Each press will increase the number by one in a cycling manner. Press the Set button again to confirm the entry, and the screen will show a blinking number representing the day of the month.
  3. Change the date and time as described in Step 2 above, using the button to change the numbers and the Set button to confirm the entries.
    DATE & TIME SET PROCEDURE

APPLYING THE CUFF

  1. Remove all watches, wrist jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped around bare skin for correct measurements.
  2. Apply cuff to left wrist with palm facing up as shown in Fig. A.
  3. Make sure the edge of the cuff is about 1/4"~1/2" (1 cm) from the palm as shown in Fig. B.
  4. In order to insure accurate measurements, fasten the hook and loop strap securely around your wrist so there is no extra space between the cuff and the wrist as shown in Fig. C. If the cuff is not wrapped tight enough, the measurement values will not be accurate.
  5. If your physician has diagnosed you with poor circulation in your left arm, place the cuff around your right wrist as shown in Fig. D.

CORRECT MEASUREMENT POSTURE

  1. Place your elbow on a table so that the cuff is at the same level as your heart as shown in Fig. A.

    warning Note: Your heart is located slightly below your armpit. Relax your entire body, especially between your elbow and fingers.
  2. If the cuff is not at the same level as your heart or if you cannot keep your arm completely still throughout the reading, use a soft object such as a folded towel to support your arm as shown in Fig. B.
  3. Turn you palm upwards.
  4. Sit upright in a chair, and take 5-6 deep breaths.
    Avoid leaning back while the measurement is being taken as shown in Fig. C.

MEASUREMENT PROCEDURE

  • Position the monitor at the same level as your heart during measurement to ensure accurate readings.
  • Blood pressure changes with every heartbeat and is in constant fluctuation throughout the day.
  • Blood pressure measurement can be affected by the position of the user, his or her physiologic condition and other factors. For greatest accuracy, wait 1 hour after exercising, bathing, eating, drinking beverages with alcohol or caffeine, or smoking to measure blood pressure.
  • Before measurement, it is suggested that you sit quietly for 15 minutes as measurements taken during a relaxed state will have greater accuracy. You should not be physically tired or exhausted while taking a measurement.
  • During the measurement, do not talk or move your arm or hand muscles.
  • See "Blood Pressure Measurement" for additional notes regarding your blood pressure measurement.

If you are using this blood pressure monitor for the first time, please remove the protective film from the screen.

  1. Press the User Select Button to choose User 1 or User 2. After the user number is selected, press the START/STOP button to confirm the chosen user.
    MEASUREMENT PROCEDURE - Step 1
  2. With the cuff wrapped around your wrist, press the START/STOP button. Do not inflate the cuff unless it is wrapped around your wrist. All digits will light up, checking the display functions. The checking procedure will be completed after about 3 seconds.
    MEASUREMENT PROCEDURE - Step 2
  3. After all symbols disappear, the display will show "00". The monitor is "Ready to Measure" and will automatically inflate the cuff to begin measurement. The cuff will then begin deflating as measurement continues.
    MEASUREMENT PROCEDURE - Step 3
    warning Note: The monitor will re-inflate automatically if the system detects that your body requires more pressure for measurement.
    MEASUREMENT PROCEDURE - Step 4
  4. When the measurement is completed, the cuff will deflate entirely and systolic pressure, diastolic pressure and pulse will be shown simultaneously on the LCD screen. The measurement is then automatically stored into memory.

warning Note:

  1. This monitor automatically turns off approximately1 minute after last operation. You may also press the START/STOP button to turn the unit off.
  2. To interrupt the measurement, you may press the START/STOP button (recommended), "MEM", user-select or Date/Time Set buttons. The cuff will deflate immediately after a button is pressed.

RISK CATEGORY INDICATOR

The U.S. Department of Health and

Human Services and the National Institutes of Health have developed a blood pressure standard, classifying blood pressure ranges into 4 stages. This unit is equipped with an innovative blood pressure classification indicator, which visually indicates the assumed risk level (normal, prehypertension, stage 1 hypertension, or stage 2 hypertension) of each reading. Symbols are described below and classifications follow the guidelines as described earlier in this manual ("Blood Pressure Standard").
RISK CATEGORY INDICATOR

RECALLING VALUES FROM MEMORY

This monitor can be used by two individuals.

Each user can store up to 60 measurements.

  1. Press the User-Select button.
  2. Choose User 1 or User 2.
  3. Press the "MEM" button to access the memory.
  4. The monitor will first display the calculated average applied to the last 3 memories ("AVG. 3").
  5. Every new press of the "MEM" button will recall a previous reading. The latest reading will be recalled first.

CLEARING VALUES FROM MEMORY

  1. Press the User-Select button to select User 1 or User 2.
  2. Press and hold the date and time set buttons ( ) at the same time while in memory recall mode and the data for the selected user will be erased automatically.
    CLEARING VALUES FROM MEMORY

IMPORTANT NOTES REGARDING YOUR BLOOD PRESSURE MEASUREMENT

  • Take your reading in a comfortable environment as measurements can be affected by hot or cold temperatures. Take your blood pressure at normal body temperature.
  • Do not move or talk during measurement as this can elevate readings.
  • Do not move or cross legs during measurement. Keep feet flat on floor.
  • Do not touch cuff or monitor during measurement procedure.
  • It is suggested that you take your measurements at the same time each day and use the same wrist for consistency.
  • Users should wait a minimum of 5 minutes before taking additional measurements. More time may be necessary depending upon your physiology.
  • The measurement results that users receive are for reference only. If users have any blood pressure concerns, please consult a physician.
  • Once inflation reaches 300 mmHg, the unit will deflate automatically for safety reasons.
  • This product is not suitable for people with arrhythmias.
  • This device may have difficulty determining the proper blood pressure for users with diabetes, poor circulation of blood, kidney problems, or for users who have suffered a stroke.

RECALIBRATION SERVICE

All digital blood pressure monitors require recalibration in order to ensure continued accuracy.

This monitor does not require recalibration for 2 years under normal usage conditions (approximately 3 times per day), at which time your monitor will display "". The unit should also be recalibrated if the monitor sustains damage due to blunt force (such as dropping) or exposure to fluids or extreme hot or cold temperature changes.

Please write down the date of first use.
(Recalibration is recommended after 2 years.)

To send monitor for recalibration, please ship to the address below with a check or money order in the amount of $10 payable to HoMedics, Inc. for recalibration service and shipping & handling:
HoMedics Recalibration Service Center P.O. Box 7050
Walled Lake, MI 48390
Allow up to 3 weeks for return of product. For additional information, contact HoMedics Consumer relations at 1-800-466-3342.

CARE, MAINTENANCE & CLEANING

  1. Clean the blood pressure monitor body and cuff carefully with a slightly damp, soft cloth. Do not press. Do not wash cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner.
  2. Leaky batteries can damage the unit. Remove the batteries when the unit will not be used for a long time.
  3. If the unit is stored near freezing, allow it to acclimate to room temperature before use.
  4. This blood pressure monitor is not field serviceable. You should not use any tool to open the device nor should you attempt to adjust anything inside the device. If you have any problems with this device, please contact HoMedics Consumer Relations (contact information on warranty page).
  5. Do not immerse the unit in water as this will result in damage to the unit.
  6. Do not subject the monitor and cuff to extreme temperatures, humidity, moisture, and direct sunlight. Protect from dust.
  7. Do not fold the cuff tightly.
  8. Do not disassemble the monitor or cuff. If in need of repair, refer to the warranty section of this manual.
  9. Do not subject the monitor to extreme shocks (do not drop on floor).
  10. Do not inflate the cuff unless wrapped around wrist.
  11. Do not wrap the cuff around body parts other than your wrist.
  12. Do not drop or insert any object into any opening.
  13. This monitor may not meet its performance specifications if stored or used outside of these temperature and humidity ranges:
    • Storage Environment
      Temperature: -4°F~140°F (-20°C~60°C)
      Humidity: Less than 85% RH
    • Operation Environment
      Temperature: 50°F~104°F (10°C ~40°C)
      Humidity: Less than 85% RH

POTENTIAL FOR ELECTROMAGNETIC INTERFERENCE

To avoid inaccurate results caused by electromagnetic interference between electrical and electronic equipments, do not use the device near a cell phone or microwave oven.

TROUBLESHOOTING

If any abnormality arises during use, please check the following points:

SYMPTOMS POSSIBLE CAUSES CORRECTION
Unit does not turn on when the START/STOP button is pushed. Batteries have run down. Replace them with two new AAA alkaline batteries.
Battery polarities have been positioned incorrectly. Re-insert the batteries in the correct positions.
EE measurement error symbol shown on display or the blood pressure value is displayed excessively low (or high). Cuff has been placed incorrectly. Wrap the cuff properly so that it is positioned correctly.
Did you talk or move during measurement? Measure again. Keep wrist steady during measurement.
Shaking of the wrist with the cuff on.
E1 error symbol shown on display Air circuit abnormality. Measure again.
E2 error symbol shown on display Inflation pressure exceeding 300 mmHg. Switch the unit off, then measure again.
E3 error symbol shown on display Error determining measurement data. Measure again.
appears on display Recalibration alert. Refer to "Recalibration Service" for more information.

Note: If the unit still does not work, contact HoMedics Consumer Relations. Under no circumstance should you disassemble or attempt to repair the unit by yourself. Contact information for HoMedics Consumer Relations Department can be found on the warranty page.

SPECIFICATIONS

Power Source: Two 1.5V DC (AAA) Alkaline batteries
Measurement Method: Oscillometric
Measurement Range: Pressure: 40~280 millimeters Mercury (mmHg)
Pulse: 40~199 beats/minute
Accuracy: Pressure: ±3 mmHg
Pulse: ±5% of reading
Pressure Sensor: Semi-conductor
Inflation: Pump driven
Deflation: Automatic Pressure release valve
Memory Capacity: 60 memories for each User (120 total)
Auto-shut-off: 1 minute after last button operation
Operation Environment: Temperature: 50°F~104°F (10°C~40°C)
Humidity: Less than 85% RH
Storage Environment: Temperature: -4°F~140°F (-20°C~60°C)
Humidity: Less than 85% RH
Weight: 0.30 lbs (140 g) (without batteries)
Wrist Circumference: 5.3" - 7.7" (13.5cm - 19.5cm)
Dimensions: 2.9"(L) x 2.6"(W) x 3.2"(H) 73mm(L) x 65mm(W) x 82mm(H)
Type BF
Device and cuff are designed to provide special protection against electrical shocks.

warning Note: These specifications are subject to change without notice.

Service & Warranty

For service or repair, do not return this unit to the retailer.
Contact HoMedics Consumer Relations at:

Mail: HoMedics, Inc. Service Center Dept. 168
3000 Pontiac Trail Fommerce Township, 48390

Email: cservice@homedics.com

Phone:
1-800-466-3342
Business Hours: 8:30am-5pm ET Monday-Friday

LIFETIME LIMITED WARRANTY (Valid in USA only)
To obtain warranty service on your HoMedics product, mail the product and your dated sales receipt (as proof of purchase), postpaid, to the following address:
HoMedics Consumer Relations Service Center Dept. 168
3000 Pontiac Trail
Commerce Township, MI 48390
No COD's will be accepted

For more information regarding our product line in the USA, please visit: www.homedics.com

Documents / Resources

References