Page 1
AC CURRENT UNIVERSAL CLAMP TESTER MODEL 200 INSTRUCTION MANUAL 1. INTRODUCTION The model 200 universal clamp tester, using a universal current transducer, is an innovative clamp tester which enables loaded cable searching and load checking in the field—without having to separate cables into single wires. The Model 200 enables selection of single-wire, single-phase, and 3-phase modes, and displays approximate values of load current.
Page 2
2. CAUTION ● Before operating this instrument, familiarize yourself with all instructions outlined in this manual. ● Always check to make sure that the function switch is set to the position. ● When making measurements, use CAUTION as dangerous voltages may be present in normally safe areas.
Page 3
3-3 Universal CT Measurement Range: 200A Jaw Size: R10mm Resolution: 100mA Accuracy: One wire(IV cable): ±5%rdg Single phase flat cable(VVF cable): ±5%rdg Three phase cable(VVR cable): Approx. value 4. DIMENSIONS AND PANEL FUNCTION ① Current Transducer ② Jaw Opening Lever ③...
Page 4
5-3. AC Current Measurement with Universal CT CAUTION: ● Note that accuracy will differ, depending upon the diameter of the cable being measured and in the case of cables with ground wires. If high-accuracy measurement is required, use the conventional current transducer.
Page 5
● If required, always return accessories with the instrument. ● When contacting us, provide the model number and serial number of your instrument. MULTI MEASURING INSTRUMENTS CO.,LTD. Akihabara Murai Bldg. 7F, 1-26 Kanda Sakuma-cho, Chiyoda-ku, Tokyo 101-0025 JAPAN TEL: +81-3-3251-7016 FAX: +81-3-3253-4278 Home Page: http://www.multimic.com/...