Summary of Contents for Sinclair THERM SMH5 B Series
Page 1
USER’S MANUAL MONOBLOCK AIR TO WATER HEAT PUMPS SMH5-xxxB(-3) SMH5-xxxBC(-3) SMH-xxxIRBC(-3) SMH-xxxIRBC2(-3) H E A T P U M P S...
Page 3
To Users Thank you for selecting Sinclair’s product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby instruct as below: (1) This instruction manual is a universal manual, some functions are only applicable to particular product.
Page 4
Contents Safety Notices (Please be sure to abide) ..............1 1. General ........................2 1.1 Home Page ........................2 1.2 Menu Page ........................3 1.3 Backlight ...........................4 2. Operation Instructions ....................4 2.1 ON/OFF ..........................4 2.2 Function Setting ........................5 2.3 User Parameter Setting ....................15 2.4 Commissioning Parameter Setting .................16 2.5 Viewing ...........................27 2.6 General Setting .......................31...
Page 5
Safety Notices (Please be sure to abide) Do not install the control where it is damp or exposed to direct sunlight. Once the air conditioning unit is installed where possibly subject to electromagnetic interference, shielded twisted pairs should be used as signal lines and other communication lines. Be sure communication lines are wired to the correct ports, or normal communication would fail.
Page 9
ON Page 2.2 Function Setting [Operation Instructions] 1.At the menu page, by touching “FUNCTION”, it will go to the function setting page as shown in the figure below. FUNCTION Setting Page 2.At the function setting page, by touching the page turning key, it will access to the last or next page. When setting is finished, by touching the menu page icon, it will directly back to the menu page;...
Page 10
Item Range Default Remarks When the water tank is unavailable, it will be Fast hot water On/Off reserved. When the water tank is available, it will be defaulted Cool + hot water Cool/Hot water Hot water to be “Hot water”; when unavailable, it will be reserved.
Page 11
●Mode setting is allowed only when the unit is turned off, otherwise a dialog box will pop up, saying “Please turn off the system first!” ●When the water tank is unavailable, only “Heat” and “Cool” mode are allowed. ●When the water tank is available, “Cool”, “Heat”, “Hot water”, “Cool+ Hot water”, and “Heat+ Hot water” are allowed.
Page 12
Timer for Quite Mode This setting will be saved by touching the corner at the upper right corner. [Notes] ●It can be set under both ON and OFF statuses, but will work only when the main unit is turned on. ●When it is set to “On”, it will automatically back to “Off”...
Page 13
2.2.7 Weekly timer [Operation Instructions] 1.At the function setting page, by touching “Weekly timer”, it will go to the setting page as shown below. 2.At the “Weekly timer” setting page, as shown in the figure below, the weekly timer can be set to “On” or “Off”. 3.At the “Weekly timer”...
Page 14
3.Then, this setting will be saved by touching the “Save” icon. [Notes] ●This function is unavailable to mini chillers. ●This setting can be activated only when “Water tank” is set to “With”. When “Water tank” is set to “Without”, this function will be deactivated. ●This setting can be done no matter if the unit is turned on or off.
Page 15
[Notes] ●When “Clock timer” has been set and “Hot water” mode is involved, in this case, if “Water tank” is changed to “Without”, “Hot water” will be automatically switched to “Heat”, and “Cool/Heat + Hot water” will be switched to “Cool/Heat”.
Page 16
[Notes] ●When “Weekly timer”, “Preset mode”,“Clock timer” “Temp. timer” have been set at the same time, then the latter takes the priority. ●This setting is valid only when the unit is turned on. ●Under the “Cool” or “Cool+Hot water” mode, the setting targets at “WT-Cool”; while under the “Heat” or “Heat+Hot water”...
Page 17
●Upon power failure, “Emergen. mode” will back to “Off”. 2.2.13 Holiday mode [Operation Instructions] At the function setting page, select “Holiday mode” and set it to “On” or “Off”. [Notes] ●This function can be activated only when the unit has been turned off, otherwise a prompt dialog box will pop up, saying “Please turn off the system frist!”.
Page 20
Displayed Range Range Full Name Default Remarks Name (°C) (°F) 20~60°C 68~140°F 45℃ /113°F High-temp series units Leaving water Normal-temp series temperature for WOT-Heat 20~55°C 68~131°F 45°C/113°F units heating (T2) Applicable to the 20~65°C 68~149°F 45°C/113°F second generation Monobloc series units Room temperature Unavailable to heating RT-Cool...
Page 21
Commissioning Function Setting Item Range Default Description When “Remote sensor” is set to “With”, it can Ctrl. state T-water out/T-room T-water out be set to “T-room”. It will decide the status of the 2-way valve under the “Cool” and “Cool + Hot water” modes.
Page 22
Commissioning Parameters Setting Full Name Display Name Range Default Remark T-HP max T-HP max 40~55°C 104~131°F 50°C/122°F 2.4.1 Ctrl. state [Operation Instructions] At the commissioning parameter setting page, by touching “Ctrl. state”, it can be set to “T-water out” or “T-room” [Notes] ●When “Remote sensor”...
Page 23
[Notes] ●This setting can be done no matter if the unit is turned on or off. ●This setting is allowed only when the water tank is available. When the water tank is unavailable, this setting will be reserved. ●It will be memorized upon power failure. 2.4.4 Water tank [Operation Instructions] At the commissioning parameter setting page, by touching “Water tank”, the control panel will access to the...
Page 24
CN 26 ●The status of the thermostat can be changed only when the unit is turned off. ●When it has been activated, “Floor debug”, “Air removal”, and “Emergen.mode” are not allowed to be activated. ●This setting will be memorized upon power failure. 2.4.6 Other thermal [Operation Instructions] 1.At the commissioning parameter setting page, by touching “Other thermal”, the control panel will access to...
Page 25
Under the “Hot water” mode, the 3-way valve will switch to the water tank, the water pump of the heat pump will always stop but the other thermal will start. Under the “Heat + Hot water” mode (“Heat” takes the priority), the other thermal only works for space heating, and the electric heater of the water tank works for water heating.
Page 26
2.4.7 Optional E-Heater [Operation Instructions] 1.At the commissioning parameter setting page, by touching “Optional E-Heater”, the control panel will access to the corresponding setting page. 2.At the “Optional E-Heater” setting page, it can be set to “1”, “2” or “Off”. 3.This setting is used to compare with the ambient temperature.
Page 27
2.4.10 Floor debug [Operation Instructions] 1.At the commissioning parameter setting page, by touching “Floor debug”, the control panel will access to the corresponding setting page. 2.At the setting page, “Floor debug”, “Segments”, “Period 1 temp”, “Segment time”, and “ΔT of segment” can be set.
Page 28
[Notes] ●This setting will not be memorized upon power failure. ●This setting can be set only when the unit has turned off. When this function has been activated, ON operation is un-allowed. ●Defrosting will quit when the defrosting temperature goes to 20 or the defrosting duration is equal to 10 ℃...
Page 29
[Notes] ●This setting will be memorized upon power failure. 2.4.15 Address [Operation Instructions] At the commissioning parameter setting page, by touching “Address”, it can be set the address. [Notes] ●It is used to set the address of the control panel for being integrated to the centralized control system. ●This setting will be memorized upon power failure.
Page 30
●Three options are available, "Without", "DHW", and "AIR".When it is set to “AIR”, it will be closed (230VAC) under the cooling/heating mode and opened under the DHW(Hot water) mode; when it is set to “DHW”, it will be closed (230VAC) under the DHW(Hot water) mode and opened under the cooling/heating mode. ●This setting is allowed only when the unit has been turned off.
Page 31
●All parameters at this page will be memorized upon power failure. 2.5 Viewing [Operation Instructions] 1.At the menu page, by touching “VIEW”, the control panel will go to the sub-menu page as shown in the figure below. VIEW Page 2.5.1 Status [Operation Instructions] 1.At the “VIEW”...
Page 32
Full Name Displayed Name Status Remarks Off/Cool/Heat/Hot “Cool” is unavailable to Status of the thermostat Thermostat water/Cool+hot water/ the heating only unit. Heat+hot water Status of other thermal source Other thermal On/Off Status of the 2-way valve 2-way valve On/Off Status of antifreeze HP-Antifree On/Off...
Page 33
2.5.3 Error [Operation Instructions] At the “VIEW” page, by touching “Error”, it is able to view errors of the unit, as shown in the figure below. Error View Page [Notes] ●The control panel can display real-time errors. And at these pages, all errors will be listed here. ●Each page displays at most 5 pieces of errors.
Page 34
Full Name Displayed Name DC bus under-voltage or voltage drop error DC under-vol. DC bus over-voltage DC over-vol. AC current protection (input side) AC curr. pro. IPM defective IPM defective PFC defective PFC defective Start failure Start failure Phase loss Phase loss Jumper cap error Jumper cap error...
Page 35
●When error log exceeds 20, the latest will supersede the earliest. 2.5.5 Version [Operation Instructions] At the “VIEW” page, by touching “Version”, the control panel will go to the version view page, where it is able to view both the program version and protocol version. 2.6 General Setting [Operation Instructions] 1.At the menu page, by touching “GENERAL”, the control panel will go to the setting page, as shown in the...
Page 36
2.6.1 Time and clock [Operation Instructions] 1.At the “GENERAL” setting page, by touching “Time&Data”, it will go to the setting page as shown in the figure below. Time&Data Page 2.The mouse roller can change the date and time value. After it, by touching the “Save” icon, this setting will be saved and directly displayed;...
Page 37
●Software operation interface is universal and its control functions may not be completely corresponding to the unit. Software operation interface may vary along with APP upgrading or different operation system. Please refer to the actual program. 3.1 Install EWPE SMART APP [Operation Instructions] 1.Scan the following QR code with your smart phone to download and install EWPE SMART APP directly.
Page 39
After selecting “ATW HP”, the APP interface will provide relevant operation instructions.
Page 41
3.2 Setting of Main Functions 1.Set mode and temperature. 2.Click Func at the left lower corner in device operation interface to enter advanced settings.
Page 43
3.3.2 Help Click “Help” and view the operation instructions of the APP. 3.3.3 Feedback Click “Feedback” to submit feedback.
Page 44
NOT CONC RNING PROT CTION OF NVIRONM NT INFORM TION CONC RNING R FRIG R NT IR CORPOR TION 16 Great Queen Street WC2B 5AH United Kingdom R PR NT TIV T C NIC PPORT...