Page 1
Vacuum/Pressure 3BA1100 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Custom construction blowers Environmentally friendly are available oil-free technology Rugged die cast aluminum...
Page 2
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 3
Vacuum/Pressure 3BA1200 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Custom construction blowers Environmentally friendly are available oil-free technology Rugged die cast aluminum Extremely quiet operation construction RUTHERFORD, NJ 07070...
Page 4
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 5
Vacuum/Pressure 3BA1300 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Rugged die cast aluminum Extremely quiet operation construction RUTHERFORD, NJ 07070...
Page 6
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 7
Vacuum/Pressure 3BA1310 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 8
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 9
Vacuum/Pressure 3BA1330 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 10
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 11
Vacuum/Pressure 3BA1400 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 12
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 13
Vacuum/Pressure 3BA1410 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 14
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 15
Vacuum/Pressure 3BA1430 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 16
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 17
Vacuum/Pressure 3BA1500 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 18
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 19
Vacuum/Pressure 3BA1510 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 20
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 21
Vacuum/Pressure 3BA1530 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction ¡...
Page 22
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 23
Vacuum/Pressure 3BA1600 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 24
10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. Fixed voltage motor tolerances are +/-10% and voltage range motors are +/-5%. Single phase motors are +/-5% tolerance.
Page 25
Vacuum/Pressure 3BA1610 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 26
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 27
Vacuum/Pressure 3BA1630 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 28
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 29
Vacuum/Pressure 3BA1640 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 30
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 31
Vacuum/Pressure 3BA1800 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 32
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 33
Vacuum/Pressure 3BA1810 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 34
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 35
Vacuum/Pressure 3BA1830 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 36
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 37
Vacuum/Pressure 3BA1840 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Custom construction blowers Environmentally friendly are available oil-free technology Rugged die cast aluminum Extremely quiet operation construction RUTHERFORD, NJ 07070...
Page 38
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 39
Vacuum/Pressure 3BA1900 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 40
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 43
Vacuum/Pressure 3BA1930 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 44
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 45
Vacuum/Pressure 3BA1943 Regenerative Blower Features: Cooler running, All motors are standard TEFC with outboard bearing provides Class F insulation, UL recognized, maintenance-free operation CE Compliant Explosion-Proof motors available Environmentally friendly Custom construction blowers oil-free technology are available Extremely quiet operation Rugged die cast aluminum construction RUTHERFORD, NJ 07070...
Page 46
All curves are rated at 14.7 psia and 68 F ambient conditions and are reported in SCFM referenced to 68 F and 14.696 psia sea level conditions. Curve values are nominal, actual performance may vary by up to 10% of the values indicated. For inlet temperatures above approximately 80 F or for handling gases other than air, please contact your Airtech sales representative for assistance. RUTHERFORD, NJ 07070 WWW.AIRTECHUSA.COM...
Page 47
Operating and Maintenance Instructions 3BA Regenerative Blowers...
Page 49
INSTALLATION & OPERATING MANUAL 3BA REGENERATIVE BLOWERS Table of Contents Section: Page Number: 1. Safety 1.1 General Safety Precautions 1.2 Clothing and Protective Gear 1.3 Electrical Safety 1.4 Vacuum and Gauge Pressure Safety 1.5 Installation/Start-up 1.6 Maintenance Procedures 1.7 Hot Surfaces 1.8 Hearing Protection 1.9 Safety Guidelines for Transport of the unit 2.
Page 50
1. Safety 1.1 General Safety Precautions WARNING: Improper operation of 3BA units can result in serious or even fatal injuries. Please make sure all personnel have read and understood this manual before operating the unit. All personnel should familiarize themselves with the units’ specifications and be careful not to exceed the unit’s capacity.
Page 51
1.4 Vacuum and Gauge Pressure Safety In order to avoid dangerous situations associated with vacuum and gauge pressure, please utilize secure mounting elements, connections, lines, fittings, and containers. Pipes/hoses must be securely connected to the inlet and discharge connections. The inlet and discharge connections and the pipes/hoses connected to them must not be closed, clogged, or soiled.
Page 52
If the unit is installed or stored in an environment with a temperature of over 104°F (40°C) be aware that the winding may be damaged and the grease might need to be changed more often. 1.6 Maintenance Procedures Before beginning work on the pump-motor unit, please take the following precautions: •...
Page 53
Please consult the table on page 27 to find the weight of the unit being handled. Do not stand or walk under suspended loads. If a 3BA unit has come in contact with any dangerous substances, it must be decontaminated before being sent to Airtech for repair evaluation.
Page 54
The seal between the bearing and the motor is not gas tight in most models, therefore these blowers are not recommended for handling of toxic or explosive gases. (Contact Airtech Vacuum, Inc. for additional options if explosive or toxic gases will be handled.)
Page 55
CAUTION! Dangerous (flammable or explosive) or aggressive (corrosive) gases should not be handled by the standard blower. Handling of flammable or aggressive gases and vapors may be possible by using a specially configured or modified blower. Contact factory for additional information.
Page 56
Table 1. Three-phase, Single Stage, 50 Hertz Rated Voltage Motor Open Flow Maximum Sound Power Current Capacity Pressure Pressure Model HP/kW (Amps) CFM/m3/hr (mbar) Level (dBA) 3BA1300-7AT06 .33/.25 200-240/345-415 2.1/1.2 48/82 -100/100 2BA1300-7AT16 .54/.4 200-240/345-415 2.6/1.5 48/82 -120/130 3BA1400-7AT06 .94/.7 200-240/345-415 3.8/2.2 84/142...
Page 57
220-250/415-460 5.5/3.2 60/102 -340/370 When operating at altitudes above 3280 feet (1000 m) above mean sea level, contact Airtech Inc. CAUTION! Operation of the unit outside the recommended range of pressures and ambient conditions will result in shorted operating life.
Page 58
Table 3. 3 Phase, Two/Three Stage, 50 Hertz Motor Open Flow Maximum Sound Rated Power Model Voltage Current Capacity Pressure Pressure HP/kW (Amps) CFM/m3/hr (mbar) Level (dBA) 3BA1310-7AT26 .94/.7 200-240/345-415 3.8/2.2 48/81.6 -120/120 3BA1410-7AT36 2.15/1.6 200-240/345-415 7.5/4.3 84/142.8 -200/190 3BA1410-7AT46 2.96/2.2 200-240/345-415 9.7/5.6...
Page 59
Table 4. 3 Phase, Two/Three Stage, 60 Hertz Rated Motor Open Flow Maximum Sound Model Power Voltage Current Capacity Pressure Pressure HP/kW (Amps) CFM/m3/hr (mbar) Level (dBA) 3BA1310-7AT26 1.11/.83 220-250/415-460 3.75/2.15 60/102 -130/130 3BA1410-7AT36 2.7/2.05 220-250/415-460 7.5/4.4 105/179 -220/210 3BA1410-7AT46 3.4/2.55 220-250/415-460 9.0/5.3 105/179...
Page 60
Table 6. Single Phase, 60 Hertz Rated Voltage Motor Open Flow Maximum Sound Power Current Capacity Pressure Pressure Model HP/kW (Amps) CFM/m3/hr (mbar) Level (dBA) 3BA1100-7AS05 0.31/0.23 30/51 -75/80 3BA1200-7AS05 0.38/0.28 115/230 5/2.8 48/82 -112/112 3BA1300-7AS15 0.6/0.44 115/230 6.0/3.0 60/102 -130/139 3BA1330-7AS15 0.6/0.44 115/230 6.0/3.0...
Page 61
Operation of any blower is possible at 87 Hertz without modification in most cases. When using a VFD to operate the blower at this frequency, refer to the nameplate for limits on vacuum and pressure, current draw and motor performance. If your specific model number is not listed above, please consult the nameplate on the unit for electrical data.
Page 62
Table 7: Single Stage – Approximate Temperature Rise Maximum Rise at 50 Hz speed Maximum Rise at 60 Hz speed Blower Model Degrees F Degrees C Degrees F Degrees C 3BA1100-7..0. 3BA1200-7..0. 3BA1300-7..0. 3BA1300-7..1. 3BA1300-7..2. 3BA1400-7..0. 3BA1400-7..1. 3BA1400-7..2. 3BA1500-7..0.
Page 63
Table 8: Two/Three Stage – Approximate Temperature Rise Maximum Rise Maximum Rise at 50 Hz speed at 60 Hz speed Blower Model Degrees F Degrees C Degrees F Degrees C 3BA1310-7..2. 3BA1410-7..3. 3BA1410-7..4. 3BA1510-7..4. 3BA1510-7..5. 3BA1610-7..1. 3BA1610-7..2. 3BA1610-7..3. 3BA1610-7..4. 3BA1610-7..5. 3BA1610-7..7.
Page 64
Table 9: Tightening Torque Specifications For non-electrical connections Thread Ft-lbs maximum torque Nm maximum torque 2.43 3.25 6.49 19.47 26.4 34.10 46.2 56.76 For electrical connections Thread Ft-lbs torque Nm torque 0.6 to 0.9 0.8 to 1.2 1.3 to 1.8 1.3 to 1.8 For metal threaded glands/unions Thread...
Page 65
Tables 1 to 4. If the relief valves were not specified in the ordering process, please contact Airtech for details, price and availability of the needed valves before commissioning the unit. Failure to use the proper relief valve may result in failure of the blower due to operation outside the applicable limits;...
Page 66
3. Installation As illustrated in Figure 1, the Airtech 3BA blower can be installed in any physical configuration. CAUTION! Regenerative blowers can have surface temperatures in excess of 320° F. To avoid burns or other physical injury, take care to avoid contact with the surfaces of the blower during and immediately after operation.
Page 67
CAUTION! Design your piping system to avoid unnecessary pressure loss, which may significantly affect the operation of any regenerative blower. Contact your Airtech representative for assistance in designing and configuring an appropriate piping system for your application. For alternation between vacuum and pressure in any application, changeover valves are available.
Page 68
3. A magnetic motor starter should always be used to connect the motor to the power supply. It is advisable to use thermal overload motor starters to provide maximum protection for the motor and wiring. All cabling used on starters should be secured with good quality cable clamps.
Page 69
4. Start-up CAUTION! Do not start the blower motor more than 10 times in one hour. If multiple and frequent start-ups are required by your application, install a minimum run timer in the motor control circuit to avoid decreased motor life and possible fire due to over-starting of the motor.
Page 70
5. Maintenance and Servicing WARNING! Be sure the power supply is disconnected and locked out before attempting to do any maintenance on the unit. It is critical that the unit be locked out from starting during maintenance as severe injury or death could result from exposure to high voltage or rotating parts.
Page 71
Bearings are grease-packed for life. 5.1 Troubleshooting Chart Fault Cause Remedy Responsible Party Motor does Two or more Check fuses, terminals, etc.. Electrician not start, no power legs for source of interruption and noise. interrupted correct. Motor does One power Check fuses, terminals, etc..
Page 72
Inlet piping Increase pipe diameter to Operator too long or too reduce pressure loss in inlet small. piping. Contact Airtech for assistance in determining correct pipe size. Leak at Check for leaks and repair if Operator connection to necessary.
Page 73
WARNING! Before attempting an on-site repair, ensure that a qualified electrician has disconnected the motor from the power supply so that accidental starting of the motor is impossible. After repairing the unit, be sure to follow the instructions noted in this manual in the Installation section (page 20).
Page 74
5.4 Disposal Dispose in accordance with all local health and safety regulations. Spare parts list are available from your local Airtech service center. Please contact your local Airtech representative for assistance. For additional assistance, please contact: Airtech, Inc.,...
Page 79
Airtech, Inc. (“Company”) Warranty Statement Company warrants that on the date of shipment to Purchaser the goods will be of the kind and quality described herein, merchantable, and free of all defects in workmanship and materials. If within one year from the date of initial operation, but not more than eighteen months...