Page 2
INTRODUCTION The PIR34 is designed to automatically turn lights on when motion and body heat is detected. The sensor has a 180° detection range with adjustable time and light level, and can be connected to existing lighting installations. The sensor can be installed inside or outside under eaves.
Page 3
Description 1. Time setting knob 2. 3LUX Sensor 3. Wire connection points 4. Sensor body 5. LUX setting knob 6. Back cover...
Page 4
Function Can identify day and night: The consumer can adjust the work ambient light. The sensor can work in the daytime and at night when it is adjusted on the “sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on the “3LUX”...
Page 5
Installation Advice The detector responds to changes in temperature, therefor the following situations should be avoided: • Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc. • Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, lights etc.
Page 6
Connection • Loosen the screw in the back and remove the bottom (Figure 1) • Connect the wiring according to the wiring diagram. • Fix the back with inflated screw on the selected position. (Figure 2) • Replace the sensor, tighten the screw and then test it. Figure 1 Figure 2 Warning...
Page 7
Wiring Diagram Sensor Information Height of installation: 1.8-2.5m Detection Distance: Max.12m...
Page 8
Testing the Sensor • Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob clockwise on the maximum (sun). • Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After 30sec warm-up, the sensor will start to work .If the sensor receives the induction signal, the lamp will turn on.
Page 9
Testing the Sensor continued Note: When testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor light will not work! Errors and Corrections The load does not work: a. Check if the connection of the power source and the load is correct.
Page 10
Errors and Corrections continued The sensor can not shut off the load automatically: a. Check if there is continual signal in the detection field. b. Check if the time delay is set to the maximum (15min) position. Please check if the power corresponds to the instruction.
Page 11
Specifications Power source 220V ~ 240V/AC Power Frequency 50Hz ~ 60Hz Ambient Light 3, 30, 300, 2000 LUX (selectable) 10s, 30s, 90s, 3min & 7min up to Time delay 15 minutes (±2min) (selectable) max: 800 Watts (incandescent lamps) Rated Load max: 400 Watts (energy-saving lamps) Detection Distance...
Page 12
MAJOR TECH (PTY) LTD T9 Industrial Village, Sam Green Road, National Contact Number: 08 61 62 5678 Tunney Ext. 9, Elandsfontein E-mail: sales@major-tech.com South Africa P .O. Box 888, Isando 1600, South Africa www.major-tech.com...