Technical Data - A.O. Smith EQ 280 G Installation And User Instructions Manual

A.o. smith water storage heaters installation and user instruction
Table of Contents

Advertisement

1.3.2 Technical data

Device category: II2H3+
DESCRIPTION
DATA NATURAL GAS G20 - 20 mbar:
Nominal heat input (lower value)
Nominal power
Inlet-pressure (G20)
Burner pressure (G20)
Gas consumption (G20) *
Diameter main orifice (G20)
Diameter pilot orifice (G20)
Warming-up time T= 45 K
DATA BUTANE G30 - 30 mbar:
Nominal heat input (lower value)
Nominal power
Inlet-pressure (G30)
Burner pressure (G30)
Gas consumption (G30) *
Diameter main orifice (G30)
Diameter pilot orifice (G30)
Warming-up time T= 45 K
DATA PROPANE G31 - 37 mbar
Nominal heat input (lower value)
Nominal power
Inlet-pressure (G31)
Burner pressure (G31)
Gas consumption (G31) *
Diameter main orifice (G31)
Diameter pilot orifice (G31)
Warming-up time T= 45 K
10
unit
EQ 280
k W
22.6
k W
19.2
mbar
20
mbar
12.5
m
3
/h
2.4
mm
3.90
mm
2 X 0,27
min.
56
k W
22.6
k W
-
mbar
30
mbar
30
kg/h
1.8
mm
2.30
mm
2 x 0.16
min.
-
k W
21.1
k W
-
mbar
37
mbar
37
kg/h
1.6
mm
2.25
mm
2 x 0.16
min.
-
EQ 380
24.0
20.4
20
8.7
2.5
4.50
2 X 0,27
61
24.0
-
30
30
1.9
2.35
2 x 0.16
-
22.9
-
37
37
1.8
2.35
2 x 0.16
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eq 380 gEq 280Eq 380

Table of Contents