Photonic Universe LFP48-100R Instruction Manual

100ah 51.2v lifepo4 battery (rack mounted)

Advertisement

Quick Links

100Ah 51.2V LiFePO4 Battery
(Rack Mounted)
LFP48-100R
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LFP48-100R and is the answer not in the manual?

Questions and answers

Summary of Contents for Photonic Universe LFP48-100R

  • Page 1 100Ah 51.2V LiFePO4 Battery (Rack Mounted) LFP48-100R INSTRUCTION MANUAL...
  • Page 2: Important Safety Precautions

    Dear Customer, Thank you very much for choosing our product. This manual contains important information about the installation, operation, and safety of the Photonic Universe LiFePO4 battery. Please read this manual carefully before installing the product. Failure to follow any instructions, warnings, as well as commonly accepted safety principles may result in an electric shock, injury or damage to the battery.
  • Page 3: Packing List

    national regulations and standards, as well as to commonly accepted safety principles of electrical installations. Packing List 1 x Lithium Iron Phosphate Battery 2 x Communication cables 4 x Cable connectors (2 x positive, 2 x negative) 1 x Ring terminal for a grounding cable 1 x Instruction Manual Installation Tools Use appropriately insulated tools to prevent accidental electric shock or short circuits.
  • Page 4: Cable Connectors

    Ports and Terminals Reset button: When the BMS is dormant, press and hold the button for 3 - 6 seconds and release. The battery will activate and the LED indicators will turn on starting from the "RUN" light for 0.5 seconds. When the BMS is active, press and hold the button for 3 - 6 seconds and release.
  • Page 5: Installation

    Important: the connector should be inserted into the battery terminal and pressed into place in full until an audible click is heard. Connecting without an audible click leaves the terminal insecure and poses a risk of overheating and fire. When disconnecting the connectors from the battery, the lock button on the connector must be pressed.
  • Page 6 Alternatively, an optional Photonic Universe surface mounted (CB series) or recess mounted (CBR series) DC circuit breaker with overcurrent protection can be purchased separately. These breakers combine an isolator switch and a thermal overcurrent breaker in one housing.
  • Page 7: Parallel Connection

    Parallel Connection To connect the batteries in parallel, keep all power switches Off. Connect the parallel Output port of the master battery to the parallel Input of the first slave battery using the RJ45 communication cables provided. Then connect the parallel Output of the first slave battery to the parallel Input of the next slave battery etc.
  • Page 8 Parallel ports pin configuration: Whilst the standard RJ45 communication cables included with the batteries can be used for quick parallel connection, the description of the pins of the Input and Output parallel ports is provided below for technical reference. Parallel Output RJ45 Parallel Input RJ45 Clarifying Clarifying...
  • Page 9 Power On: 1. Check all power and communication cables and connections, ensure they are correct and tight. Double check the polarity of connection. 2. Turn on the external isolator switch or circuit breaker used between the battery(ies) and your equipment. 3.
  • Page 10: Rs232 Communication Port

    RS232 Communication Port The RS232 port on the battery can be used to connect the battery to a computer which will allow the battery parameters to be viewed and adjusted. The PIN configuration for this port is shown below: PIN No PIN Configuration PIN 1 NC (Empty)
  • Page 11 PIN 3 to PIN 4 will close in the event of the fault protection being activated: Condition PIN 3 & PIN 4 Normal Open Fault Protection Active Closed RS485 and CAN Port Configuration The RS485 and CAN ports are used for communication between the battery and an inverter. RS485 port configuration: PIN 1 RS485-B...
  • Page 12: Led Status

    BMS Functions The built in BMS will perform several functions to protect the battery and to manage and monitor the battery performance. Protection and alarm: • End of charging and discharging • Charging over voltage • Discharging under voltage • Charging and discharging over current •...
  • Page 13: Troubleshooting

    Troubleshooting If the battery is not turning on: Turn the battery power ON/OFF switch into the ON position. Turn the red ON/OFF switch into the ON position to verify if any of the LED indicators are flashing. Use a charger or inverter to charge the battery at 48V-53.5V*. If after charging, the battery switches on, then keep the battery charged and use the monitoring tools to check the log.
  • Page 14: Specifications

    Please ensure that the battery terminals and the inverter terminals are not reversed CAN pin issue. Try connecting the CAN-H, L and GND only and do not connect other pins to the inverter. Specifications Specifications Parameter LFP24-100R LFP48-100R Nominal voltage 25.6V 51.2V Discharge voltage 21.6-29.2V 43.2-58.4V Charging voltage 29.2V...
  • Page 15: Emergency Situations

    Emergency situations If the battery is leaking: If the battery is leaking electrolyte, avoid any physical contact with the liquid or gas. If physical contact is made with the batteries follow the steps below: • If gas from the battery has been inhaled, leave the area in which the battery is located and seek medical attention.
  • Page 16: Battery Cleaning

    As a reminder of the need to dispose of this battery properly, the product is marked with a crossed-out wheeled bin. Always follow the local and national regulations when disposing of this battery. Photonic Universe Ltd E-mail: info@photonicuniverse.com Web: www.photonicuniverse.com...