Summary of Contents for Commercial Electric KMNO-301
Page 1
Retain this manual for future use. THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this digital multimeter. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
HOMEDEPOT.COM THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this digital multimeter. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
Safety Information Safety Information (continued) PRECAUTIONS Please read this manual carefully and pay attention to related safe working standards before using this meter. Protection provided by the instrument will be impaired if used in a manner WARNING: Measure known WARNING: When measuring, not specified by the manufacturer.
Safety Information (continued) Safety Information (continued) FCC COMPLIANCE STATEMENT WARNING: Do not attempt to CAUTION: Pay attention to the measure resistance or continuity battery polarity when changing the WARNING: This device complies with Part 15 of the FCC Rules. on a live circuit. battery.
Pre-Operation Pre-Operation (continued) PRODUCT DESCRIPTION LCD DISPLAY DEFINITIONS Part Symbol Description Active auto power off indicator Alternating current indicator Direct current indicator Numerical value polarity indicator (negative sign) Data hold indicator High voltage warning symbol (> 30V AC RMS or 30V DC) Measurement display value Low battery indicator Part Name...
Pre-Operation (continued) Pre-Operation (continued) PRODUCT SPECIFICATIONS AC VOLTAGE SPECIFICATIONS Measuring Range Resolution Accuracy Component Specification 200.0V 0.1V ±(1.0% of reading + 3 digits) LCD display 2000 counts 600V ±(1.2% of reading + 5 digits) Sampling frequency 3 samples per second □...
Page 7
Pre-Operation (continued) Pre-Operation (continued) BATTERY VOLTAGE SPECIFICATIONS Position Resolution Load Impedance WARNING: □ All other measurements: must insert RED test leads to 1.5V 0.001V 100Ω the right socket. 0.01V 450Ω □ Do not use these ranges to measure HIGH VOLTAGE. 0.01V 120Ω...
Operation Operation (continued) AC Voltage Measurement DC Current Measurement (≤ 600V) (≤ 200mA) WARNING: Do not attempt to WARNING: Do not attempt to measure more than 200mA. measure over 600V or 200mA. □ For mA DC current less than 200mA, rotate the rotary switch (D) to the highest □...
Page 9
Operation (continued) Operation (continued) Resistance Diode Test Measurement □ Rotate the rotary switch (D) to continuity/ WARNING: Do not attempt to diode ( ) setting. Insert the RED measure resistance on a live circuit. test lead (J) into positive input jack (H) □...
Maintenance (continued) Maintenance BATTERY REPLACEMENT WARNING: Before you open the WARNING: When you open the □ Once indicator is displayed on meter, always disconnect it from meter, remember that some internal the LCD display (A), batteries must be all sources of electrical current and capacitors can retain a dangerous replaced.
THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this outlet tester. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for...
Page 12
Safety Information Safety Information (continued) PRECAUTIONS Symbol Definition CAUTION: Make sure the WARNING: BE EXTREMELY Indicates important safety information. GFCI receptacle is installed in CAREFUL IN THE USE OF TH DEVICE. accordance with the manufacturer's Improper use of this device can Caution! Indicates a potentially hazardous situation.
Page 13
Safety Information (continued) Pre-Operation FCC COMPLIANCE STATEMENT PRODUCT DESCRIPTION WARNING: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Pre-Operation (continued) Pre-Operation (continued) LCD DISPLAY DEFINITIONS PRODUCT SPECIFICATIONS Component Specification Battery 2 x AAA 1.5V batteries Operating voltage 30 to 150V 50/60Hz Measure voltage (with LCD) 85 to 135V 50/60Hz Operating power Operating altitude < 6560 ft. (2000 m), indoor use only 32°F to 104°F (0°C to 40°C), <...
Operation Operation (continued) Standard Receptacles Testing GFCI Receptacles Testing WARNING: For use on North American CAUTION: If the detected voltage is either WARNING: For use on North American CAUTION: When testing GFCIs installed 120V outlets only. Do not connect to higher low (30–85V AC) or high (135–150V AC), the 120V outlets only.
Care and Cleaning Maintenance BATTERY REPLACEMENT □ Keep the detector dry. If it gets wet, wipe it off. □ Keep the detector clean. Wipe off dirt with a soft cloth dampened with water. Do not use WARNING: To avoid electric chemicals, cleaning solvents, or detergents.
Page 17
THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this voltage detector. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for choosing Commercial Electric! HOMEDEPOT.COM...
Safety Information (continued) Pre-Operation FCC COMPLIANCE STATEMENT PRODUCT DESCRIPTION WARNING: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Pre-Operation (continued) Operation PREPARATION - BEFORE MEASUREMENT WARNING: Risk of Electrocution. WARNING: Risk of Electrocution. High-voltage circuits, both AC and Before using to check for voltage in SELF TEST MODE NCV FUNCTION ON/OFF DC, are very dangerous and should a socket, always test the detector The self-test function tells if the detector is □...
Page 20
Care and Cleaning Maintenance BATTERY REPLACEMENT □ Keep the detector dry. If it gets wet, wipe it off. □ Keep the detector clean. Wipe off dirt with a soft cloth dampened with water. Do not use chemicals, cleaning solvents, or detergents. WARNING: To avoid electric □...
Need help?
Do you have a question about the KMNO-301 and is the answer not in the manual?
Questions and answers