Download Print this page
urmet domus 1036/37 Quick Manual

urmet domus 1036/37 Quick Manual

U1 lift control module (485 protocol)

Advertisement

Quick Links

U1 Lift Control Module (485 protocol) Quick Manual
Code: SRD-UME1036/37-0104-V1.3
Product Description
The Lift Control Module is used for forwarding the command from U1 Monitor and Call
Module to the corresponding Lift Control system.
When the Monitor or Call Module performs "Call Lift" function (likes other unlocking
functions namely call unlocking, card unlocking, user password unlocking), a control
command is forwarded to the lift control system to realize the linkage between the Lift and
U1.
Specifications
SN
Description
Parameters
1
Working Voltage
DC 24±5V
≤ 200 mA(DC 24V)
2
Working Current
≤ 200 mV
3
Power Ripple
4
POE Voltage
DC 24±5V
5
Working Humidity
35%~90%
Remark:
If 485 compatible pull-up/down resistor is not added by default, set the jumper if
required.
1036/37
Version: V1.3
SN
Description
6
Network
100m
transmission
max.(CAT5)
7
485 Transmission
300m max.
distance
8
485 compatible
120Ω/ 1K
Pull-up/down
resistor
-10℃~+55℃
9
Working Temp
-20℃~+70℃
10
Storage Temp
1
DIMENSIONS
Overall dimensions (L×W×D):144×90×64 mm
Instruction for user
③Output
Parameters
LED
Port Description
① Power Input: DC +24V± 5V
② Network Port : RJ45:1、2 RX+、RX- ,3、6 TX+ 、TX- (support non-standard
DC24V POE)
③ Output port : 485-A:485 connect A port 485-B:485 connect B port
144.00mm
64.00mm
②Network Port
DC+
2
① Power Input
GND

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1036/37 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for urmet domus 1036/37

  • Page 1 DIMENSIONS Overall dimensions (L×W×D):144×90×64 mm U1 Lift Control Module (485 protocol) Quick Manual 1036/37 144.00mm 64.00mm Version: V1.3 Code: SRD-UME1036/37-0104-V1.3 Product Description The Lift Control Module is used for forwarding the command from U1 Monitor and Call Instruction for user Module to the corresponding Lift Control system.
  • Page 2 Indicator Light: POWER:The Red Indicator Light on the left will be on if it is connected to the DC power supply or POE power supply. LINK:The Green Network Connection Status Light in the middle will be on if the connection is correct without any IP conflicts.