ILSENMW003 MICROWAVE SENSOR FOR RECESS MOUNT
Thank you for purchasing an INTEGRAL LED product. When installed correctly this unit will provide years of service – with no
replacements required. For support or warranty information please see integral-led.com. Always turn off circuit power at the
distribution unit before installation and maintenance. Please ensure that the power cannot be connected inadvertently.
Important Details – Please read prior to installation
• This sensor must be installed by a qualified electrician in accordance with the instructions provided and in compliance with
recognised electrical and safety regulations relevant to the country it is being installed.
• This is a Class II sensor. Earth connection is not required.
• The input voltage of this sensor is 200-240V~ 50/60Hz
• This sensor is only suitable for recess mount. Adequate for installation on surfaces with normal flammability e.g. wood,
masonry. Before making the fixing hole(s), check that there are no obstructions hidden beneath the mounting surface, such
as pipes or cables. Do not use on highly flammable surfaces or in flammable atmosphere.
• This sensor is designed to be installed in a ceiling tile/solid material, with a minimum thickness of 3mm.
• This product is for Indoor use only. It should not be covered with insulation material at any time.
• This product is not suitable for dimming.
• Ensure mains supply is isolated before starting any work.
• Operating Temperature: -20°C to +40°C. Do not exceed.
• Should the unit malfunction, return to distributor or reseller. No user serviceable parts inside. Do not disassemble or attempt
to repair the sensor outside of the installation guidelines.
• Do not install or use the sensor if the housing is found to be broken.
Installation Instructions
•
Ensure the AC/mains power is not connected and cannot be reconnected during installation.
•
For new installations use cutting tools suitable for the material and carefully cut the required hole to allow installation.
•
For Refurbishment installations ensure that the existing hole is suitable and strong enough to hold the new sensor. Support
the surrounding area if required.
•
Remove the transparent terminal cover, unscrew the connection terminals and connect the Mains power and the Load wires
according to the wiring diagram (See Fig.1 and Fig.2).
•
Re-install the transparent terminal cover, switch on the Mains power supply and test.
•
Once tested and in good working order, raise the springs, place the sensor into the cut-out ensuring that no power cables are
trapped and position fully into the aperture until sensor is flush to the surface
SPECIFICATION:
Mains Input: 220 -240V/AC, 50/60Hz
Ambient Light: <10-2000LUX (adjustable)
Time Delay:
Min.10sec±3sec
Max.15min±3 min
Rated Load:
1200W
300W
INSTALLATION INSTRUCTION
3 Year Warranty
Detection Range: 360°
Detection Distance: 3-10m (radius, adjustable)
Frequency: 5.8GHz, ISM band
Power Consumption: approx. 0.9W
Installation Height: 1.5-3.5m
Detection Motion Speed: 0.6-1.5m/s