Big Dutchman BDI 30000 User Manual

Weighing computer for platform weighing

Advertisement

Quick Links

User manual
Weighing computer BDI 30000
for platform weighing
Code No. 99-97-1781 GB
Edition: 12/2009
Code no. 83-07-8405

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BDI 30000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Big Dutchman BDI 30000

  • Page 1 User manual Weighing computer BDI 30000 for platform weighing Code No. 99-97-1781 GB Edition: 12/2009 Code no. 83-07-8405...
  • Page 2: Table Of Contents

    User manual for Indicator BWI INDEX 1. INTRODUCTION ......................3 2. TECHNICAL SPECIFICATIONS ..................3 3. DISPLAY .......................... 4 4. KEYBOARD ........................5 5. Fundamental information ....................6 5.1 Intended use ......................6 5.2 Inappropriate use ....................... 6 5.3 Guarantee ........................6 5.4 Monitoring the test substances ...................
  • Page 3: Introduction

    1. INTRODUCTION Please read the operating instructions carefully before erecting and commissioning, even if you already have experience with Big Dutchman scales. The BWI is a general purpose indicator for displaying weight. All the displays are large easy to read liquid crystal type displays (LCD). The LCD’s are supplied with a LED backlight.
  • Page 4: Display

    User manual for Indicator BWI 3. DISPLAY The LCD display will show a value and a unit to the right of the digits. In addition there are labels for TARE, GROSS weight, ZERO, Stable and for Low battery Battery needs charging STABLE The weight is stable - when the weight value is being displayed without fluctuation ZERO...
  • Page 5: Keyboard

    User manual for Indicator BWI 4. KEYBOARD BWI 30 000 Normal mode Setting mode A secondary function, is to return to Gross weight/net weight shift key normal operation when the scale is in a parameter setting mode. Gross/Net To print the results to a PC or printer Delete.
  • Page 6: Fundamental Information

    Warranty starts from the date of delivery. Big Dutchman shall have the right to either repair the fault or supply a replacement unit. Repairs carried out under the warranty does not extend the warranty period.
  • Page 7: Installation

    User manual for Indicator BWI 6. INSTALLATION 6.1 INSTALLATION OF BWI SERIES 6.1.1 Pillar The pillar is attached to the base using a bracket that must first be attached to the base frame using the 4 bolts supplied. The Pillar is secured to the bracket using 2 set screws. The cable from the base to the indicator module is run through the tube, out through the plastic support at the top.
  • Page 8: General Installation

    User manual for Indicator BWI 6.2 GENERAL INSTALLATION The scales should be sited in a location that will not degrade the accuracy. The scales should not be placed in a location that will reduce the • accuracy. Avoid extremes of temperature. Do not place in direct sunlight or •...
  • Page 9: Weighing

    User manual for Indicator BWI 7. WEIGHING Switch the indicator on by pressing the key. Next a self-test is followed. At the end of the self-test, it will display “0”. The display shows STABLE-, GROSS-, ZERO symbol. A warm-up time of 15 minutes stabilises the measured values after switching on. Once the weight display appears, the scale is ready for use.
  • Page 10 User manual for Indicator BWI 7.4 TARE WEIGHING The weight of any weighing container can be subtracted from the gross weight with the press of a key, so that subsequent weight measurements always display the item’s net weight. Place the empty container on the platform. The total weight of the container and GROSS will be displayed.
  • Page 11: Accumulated Total

    User manual for Indicator BWI 7.4 ACCUMULATED TOTAL The scale can be set to accumulate manually by pressing the key. See the PARAMETERS Section for details of selecting the method using function "P2 com". 7.4.1 Accumulate operate The weight displayed will be stored in memory when the key is pressed and the weight is stable.
  • Page 12: Check-Weighing

    User manual for Indicator BWI 7.5 CHECK-WEIGHING Check-weighing is a procedure to cause an alarm to sound when the weight on the scale meets or exceeds values stored in memory. The memory holds values for a high limit and a low limit. 7.5.1 Set limits After you enter the value, press key to sure, press...
  • Page 13: Dynamic Weighing - Animal Weighing

    User manual for Indicator BWI 7.6 DYNAMIC WEIGHING – ANIMAL WEIGHING If "itself moving loads" like living animals should be weighed, the scale can be switched to the dynamic cradle mode. In this case the scale weighs 20 times per second, and a calculated average value is indicated and held.
  • Page 14: Parameter

    User manual for Indicator BWI 9. PARAMETER The scale has 5 parameters that can be set by the user plus a method of entering the calibration section. The first indicated value, is the standard increment of the balance. In order to select another increment, press .
  • Page 15: Parameter Setting Table

    User manual for Indicator BWI 9.1 PARAMETER SETTING TABLE Function Sub Function Describe F0Cki SEt L Set high limit, press key to move active digit, press to change value, press key to clear data, press key to sure. SEt k Set high limit, press key to move active digit, press to change...
  • Page 16: Calibration

    User manual for Indicator BWI 10. CALIBRATION As the acceleration value due to gravity is not the same at every location on earth, each scale must be coordinated – in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location ( only if the balance has not already been adjusted to the location in the factory).
  • Page 17: Rs 232 Device

    User manual for Indicator BWI 12. RS 232 Interface The RS-232 Interface is for output of weighing results. The RS-232 is normally configured to print a weight when the value is stored into memory, either automatically or when the key is pressed. The announcements of the TWI series can be equipped when desi red with R-S 232 interface.
  • Page 18: Print Output

    User manual for Indicator BWI P<cr><lf> By using this key, results can be sent to a printer or a PC by the (optional) RS-232 interface. If the distribution memory is not adjusted on mechanism, the scale adds the value to the distribution memory.
  • Page 19: Maintenance, Disposal

    Loose sample residue/powder can be removed carefully using a brush. 13.2 MAINTENANCE, UPKEEP The device may only be opened by trained service engineers authorised by Big Dutchman. Disconnect from the mains supply before opening. The battery is not water-proof, so the contact with water is forbidden. If the battery should become wet or it is visible damaged, don’t use the battery.
  • Page 20: Error Codes

    Over range Remove weight from the scale. ------ If the problem persist contact your dealer or Big Dutchman for assistance. Please do not add item that is over the maximum capacity. --oL-- When reading “—OL—“ and hear beeping sound, remove the item on the platter to avoid damage to the load cell.
  • Page 21: Service Information

    • Has it been in contact with water • Damaged from a fire • Electrical Storms in the area • Dropped on the floor, etc. Contact: Big Dutchman Pig Equipment GmbH Auf der Lage 2 49377 Vechta Tel. +49 4447 801-0 Fax +49 4447 801 237...
  • Page 22: Konformitätserklärung Des Herstellers

    User manual for Indicator BWI KONFORMITÄTSERKLÄRUNG DES HERSTELLERS Konformitätserklärung für Geräte mit CE-Zeichen Die nicht selbsttätige elektronische Auswertelektronik Typ: Bosche Anzeige Dieses Produkt ist in Konformität mit den harmonisierten europäischen Standards hergestellt worden, entsprechend den Kriterien der nachstehenden Richtlinien: EG - Richtlinie Harmonisierte Normen 89/336/EEC EMC EN 50081-1...