Big Dutchman Viper User Manual

Climate and production computer
Hide thumbs Also See for Viper:

Advertisement

Code No: 99-97-1963
(V5.2)
Viper Climate and
Production Computer
User's Manual • Basic-Step

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Viper and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Big Dutchman Viper

  • Page 1 Code No: 99-97-1963 (V5.2) Viper Climate and Production Computer User's Manual • Basic-Step...
  • Page 3: Program Version

    Should any mistakes or imprecise information occur in spite of this, Big Dutchman would appreciate being notified hereof • Irrespective of the above, Big Dutchman shall not accept any liability with regard to loss or damage caused or alleged to be caused by reliance on any information contained herein •...
  • Page 4 Pressure Control ...................... 26 2.2.6.1 Reading the Pressure Demand ..................27 2.2.6.2 Setting and Reading the Pressure Level................27 2.2.7 Auxiliary Sensors..................... 28 2.2.7.1 Reading the Auxiliary Sensors ..................29 2.2.7.2 Auxiliary Sensor Curve ....................30 INDEX Viper Climate and Production Computer...
  • Page 5 Furthermore, the structure of the manual follows the menu structure of the computer. As the Viper software is modular software, this manual will contain sections that are irrelevant to the setup of your computer. If in doubt, please contact Big Dutchman service or your Big Dutchman dealer.
  • Page 6: Get Started

    Values, which are readings or cal- culations, are in normal type The values and functions, which you can change, are highlighted bold type Viper Climate and Production Computer...
  • Page 7: Display And Menus

    The current time and date are indicated farthest to the right. When, in connection with setup or service, the computer is set to manual regulation of the system, Viper will indicate the manual control in the message line. Viper Climate and Production Computer...
  • Page 8 From this menu, you can read the values of the individual inputs. 2.1.2.1.3.2 utline of Climate Functions → press on the numeric keyboard From this menu, you have direct access to change the values set. (e.g. Temperature setpoint Viper Climate and Production Computer...
  • Page 9: Function Menus

    Technical have to be changed only if changes are made to the actual installation (if necessary, see the Technical Manual). All the Viper functions can be accessed via these menus by selecting the required function (e.g. ), and pressing the...
  • Page 10 Room heat Start tunnel Stop tunnel Tunnel control Thus, if you change by 2 °C, Viper will automatically change these Target temp. Target temp. settings by a corresponding number of degrees. Example 1: Dependent temperature settings Temperature °C...
  • Page 11 When only 1/3 and 2/3 of the house are used as grow zone ( Grow zone 1 Viper can control both the heaters in the active zones and ensure that they run at minimum in the inactive grow zones. This way, you avoid condensate on the curtains, and the inactive zones are heated faster when they are to be used as grow zones again.
  • Page 12 In each control matrix you can choose between five timer functions (see Fehler! Verweisquelle konnte nicht gefunden werden.). The graphs in Fehler! Verweisquelle konnte nicht gefunden werden. corresponds to these settings: ON-time 60 sec. Cykle time 300 sec. ON-temperature 30 °C OFF-temperature 29 °C Temperature decreases Temperature increases Viper Climate and Production Computer...
  • Page 13 Tun on Side fans ON/OFF Tunnel fans Spray cooling PAD cooling House heaters C° Brooding heaters Sec. Side fans ON/OFF Stir fan timer Tunnel fans C° Sec. Ramp C° Table 4: Setting options for timer functions Viper Climate and Production Computer...
  • Page 14 When you want to... set a timer, open the menu, and Control → select , and press Timer setup → select the required field, and press → set a number of seconds → set a mode Viper Climate and Production Computer...
  • Page 15: Inside Temperature

    Table 5: Outline of the temperature menu (changeable values are highlighted in bold types) 2.2.2.1 Inside Temperature Viper controls the inside temperature according to the set temperature. The house is heated by the heat generated by the animals and possibly by a heating system.
  • Page 16 When the individual temperature sensor has been assigned to a zone, it will be active only when the associated zone is active. Thus, the sensors in Grow zone 2 and 3 are inactive when Grow zone 2 and 3 are inactive. Viper’s temperature indication therefore depends on which grow zone is active.
  • Page 17 Grow zone 1 several smaller zones, brooding zones, where the heat is concentrated around a smaller area in the grow zone. Viper controls the temperature in the brooding zones and heats them by means of heaters. When you want to …...
  • Page 18 Outside temperature → select , and press Trend outside temp. → turn the rotary button to read the exact time and figure values → press the rotary button to return to the outside temperature menu Viper Climate and Production Computer...
  • Page 19 The combination of a high inside temperature and high air humidity can be life threatening to the animals. As cooling makes the house humidity increase, Viper will automatically disconnect cooling when the house humidity exceeds Stop cooling (normally 75-85 %).
  • Page 20 This section is relevant only to houses with humidity sensors. The Viper computer can show you the humidity content of the house air. Humidity is supplied to the house air partly from animals, feed, drinking water and litter, and partly from the cooling function.
  • Page 21 Climate Humidity → select , and press Trend humidity → turn the rotary button to read the exact time and figure values → press the rotary button to return to the humidity menu Viper Climate and Production Computer...
  • Page 22 The house ventilation consists of an air inlet and an air outlet. Apart from supplying fresh air to the house, ventilation is to remove any humidity and excess heat. Viper continuously adjusts the ventilation according to a calculation of the current ventilation requirement. Thus, the computer will increase or limit ventilation according to whether the inside temperature and air humidity are too high or too low.
  • Page 23 Thus, the percentage indications are particularly relevant in connection with fault finding. When you want to … read the ventilation status, open the menu, and Climate Ventilation Ventilation status → read the required menu item Viper Climate and Production Computer...
  • Page 24 All menu items … in the menu can be read and set by Tunnel → pressing the menu key → select , and press Climate → select , and press Tunnel Viper Climate and Production Computer...
  • Page 25 The combination of a high house temperature and high air humidity can be life threatening to the animals. Pad cooling should, therefore, be disconnected when air humidity is very high since cooling will increase air humidity further. Viper Climate and Production Computer...
  • Page 26: Pressure Control

    This section is relevant only to houses with pressure sensors. By means of a pressure sensor, the Viper computer can control the pressure level in the house. On the basis of the sensor measurements, Viper controls the opening of the flaps; in this way, it maintains the...
  • Page 27 → read the menu item 2.2.6.2 Setting and Reading the Pressure Level In the menu, indicate the pressure level which Viper is to maintain. You can Pressure setpoint read the current pressure level in the house under the menu item...
  • Page 28: Auxiliary Sensors

    Table 10: Outline of the auxiliary sensors menu This section is relevant only to houses with auxiliary sensors. In the menu, you can read Viper’s registrations from the auxiliary sensors installed. Aux. sensors , pressure, NH , temperature, humidity, air speed and wind direction sensors can be connected.
  • Page 29 Climate Aux. sensors → select , and press Aux. sensor 1 → read the sensor registration Repeat the reading for the installed number of sensors. Viper Climate and Production Computer...
  • Page 30 → turn the rotary button to read the exact time and figure values → press the rotary button to return to the Aux. sensor 1 menu Repeat the reading for the installed number of sensors. Viper Climate and Production Computer...
  • Page 31 User's Manual • Basic-Step 3 INDEX Fejl! Har ikke fundet nogen opslagsord. Viper Climate and Production Computer...
  • Page 32 BIG DUTCHMAN International GmbH • Calveslage • Auf der Lage 2 • 49377 Vechta Tel. 04447/801-0 • Fax 04447/801-237...

Table of Contents