Among various indoor gases, CO2 is the gas that best represents indoor air quality. High concentrations of CO2 can cause headaches, fatigue, rapid heartbeat, and shortness of breath. Prolonged exposure to high levels of CO2 may have negative effects on the respiratory system and may even lead to diseases such as tracheitis and pneumonia. Therefore, it is vitally important to maintain an appropriate range of indoor CO2 concentration for the sake of health.
That's why we have introduced IAM-T1, Smart Indoor Air Quality Monitor that helps you stay safe and healthy.
Sensor performance | Range | Resolution | Accuracy |
CO2 concentration | 0- 9999 ppm | 1ppm | ± 30 ppm * ± 3% of reading |
Temperature | 0 - 50ºC | 0.1ºC (0.1ºF) | ±0.3ºC(±0.5ºF) |
Relative humidity | 0-85% | 1% | |
Atmospheric pressure | 600 1100 hPa | 1hPa | -2 hPa / +3 hPa |
* CO2 measurement accuracy is provided for arange0 5000ppm, temperature 15... 35ºC (59... 95ºF) and relative humidity 0... 80%. Accuracy above 5000 ppm is 10% of reading, but not guaranteed since it is extrapolated form the calibrated range.
Please install the supplied batteries correctly according to the "+" and "-"marks on the battery compartment.
Stand on the table
Hang on the wall
Auto-Calibration icon
— the smart auto-calibration is turned on.
— No icon is displayed, the smart auto-calibration is turned off.
Bluetooth icon
— Bluetooth is turned on but not in the connecting
— App connecting
— No icon is displayed, BIuetooth turned OFF
Buzzer Switch Icon
Displayed buzzer sound on the device is turned on;
Disappears the buzzer sound is turned off
Note: The buzzer's settings can be adjusted using the INKBIRD app!
CO2 Concentration Value (ppm)
CO2 concentration level in ppm (parts per million).
CO2 Threshold Level Indicator
When the progress bar is within the green part , the CO2 concentration level is in a good state (<1000 ppm).
When the progress bar is within the yellow part , the CO2 concentration level is in a medium state (1000~1400 ppm).
When the progress bar is within the red part , the CO2 concentration level is in an unhealthy state ( > 1400 ppm).
Note: These are default thresholds that can be reconfigured using the INKBIRD app.
Temperature (ºC/ ºF)
Temperature: the temperature of the air in ºC or ºF
Note: See the Key Definitions in this manual to understand how to change temperature unit.
Relative Humidity ( % )
the relative humidity of the air, expressed in RH%.
Startup Interface
When the device is powered on with a battery installed, it will be initialized. Please wait for a few seconds!
CO2 Alarm Interface
When the CO2 level exceeds the preset alarm value, the display on the screen will become black and white. The alarm is triggered by the unhealthy state (red) by default The alarm value can be customized through the App.
Low Battery Interface
If the battery is exhausted, replace it as soon as possible Try to use 2* AA alkaline batteries with a higher capacity. ( ≥ 2500mah)
Too-low Ambient Temperature
Interface This interface will be displayed when the ambient temperature is lower than 0ºC. The temperature measurement range of the device is 0~50ºC, and temperature beyond the range will affect the normal operation of the device.
CO2 Detection Error
The detected CO2 concentration may exceed 9999 ppm. Please do not exhale directly into the device, as the gas concentration from the human body can be as high as 30000 - 50000 ppm Please use this device within the detection range
Button:
Short press: press it to change the temperature unit, ºC/ ºF.
Tip: When Bluetooth is connecting, press it to pair
Long press: Press and hold the button for 5 seconds to unbind the device and restore it to factory settings
Bluetooth Switch:
ON: Bluetooth IS enabled
OFF: Bluetooth is disabled
Wall mount hole
Unhealthy data alarm: When the CO2 concentration reaches an unhealthy state(red),the device emits a soft "beep"buzzing sound
Settings on the App:
ISSUES | POSSIBLE SOLUTIONS |
The value of CO2/ temperature/humidity did not change for a long time |
|
The device displays "error: 1050" |
|
CO2 calibration | The monitor is calibrated at the factory. However, the user can carry out CO2 calibration manually when needed. The general recommendation is to calibrate once a year, but more often if it is used in dusty environments. During the manual calibration, the device must be exposed to fresh outdoor air. Keep a distance of at least one meter from the device during the calibration process - no humans, animals, or plants should be closer to the device during calibration. |
Customer Service
Please keep this manual properly for reference. You can also scan the QR code below to visit our official website for product usage videos.
For any usage issues, please feel free to contact us at support@inkbird.com.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the IAM-T1 and is the answer not in the manual?
Questions and answers