Cooper Lighting Solutions Streetworks Archeon Small Installation Instructions Manual

Advertisement

Available languages

Available languages

IB50606822
Installation Instructions - Archeon Small
Instructions d'installation - Archeon Small
Instrucciones de instalación - Archeon Small
IMPORTANT: Read carefully before installing product. Retain for future reference. Failure to comply with these
instructions may result in death, serious bodily injury and property damage.
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this
product must be performed by a qualified electrician. This product must be installed in accordance
with the applicable installation code by a person familiar with the construction and operation of the
product and hazards involved.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting
any maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Refer to product label for specific minimum supply conductor requirements.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind
that may arise from the improper, careless, or negligent installation, handling or use of this product.
NOTICE: Green ground screw provided in proper location. Do not relocate.
ATTENTION Receiving Department: Note actual product description of any shortage or noticeable damage on
delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be
filed within 15 days of delivery. All damaged material, complete with original packing must be retained.
Note: These instructions do not claim to cover all details or variations in the equipment, procedure, or process
described, nor to provide directions for meeting every possible contingency during installation, operation
or main-tenance. When additional information is desired to satisfy a problem not covered sufficiently for
user's purpose, please contact your nearest representative.
Note: This lighting fixture has been shipped complete with one of several mounting options. Please follow the
installation instructions specific to the catalog part that you ordered.
Note: Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area.
Note: Specifications and dimensions subject to change without notice.
Safety: This product must be wired in accordance with the National Electrical Code and applicable local codes
and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure
under installation section.
WARNING
WARNING
Brand Logo
reversed out of
black
INS #
INS #

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Streetworks Archeon Small and is the answer not in the manual?

Questions and answers

Summary of Contents for Cooper Lighting Solutions Streetworks Archeon Small

  • Page 1 Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly. DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product.
  • Page 2: Installation

    Using a 9/16” socket, tighten the clamp bolts to 16-18 ft-lbs Door Latch Bird Guard Cutout for Larger (4) Bolts 3/8” Diameter Arm (2) Pipe Clamp Figure 3. Leveling Steps Figure 1. Cooper Lighting Solutions IB50606822 Installation instructions...
  • Page 3 Insert nut plate into pole and align insert holes with the mounting holes in the pole. (2) Washers Insert threaded rods through the top and bottom holes. Screw into nut plate. Electrical Wires Square Pole Figure 6. Cooper Lighting Solutions IB50606822 Installation instructions...
  • Page 4: Maintenance

    Additional cleaning can be performed with using a non-abrasive polycarbonate cleaner. Remove any dirt, leaves or other foreign debris from the housing. Figure 9. Cooper Lighting Solutions IB50606822 Installation instructions...
  • Page 5 Risques de blessures – Le luminaire peut être endommagé et/ou instable s’il n’est pas installé correctement. EXONÉRATION DE RESPONSABILITÉ : Cooper Lighting Solutions n’assume aucune responsabilité pour les dommages ou pertes de quelque nature que ce soit pouvant découler d’une installation, d’une manipulation ou d’une utilisation inappropriée, imprudente ou négligente de ce produit.
  • Page 6: Outils Requis

    Alvéole défonçable pour diamètre de bras plus grand Dispositif de protection contre les Loquet oiseaux Figure 3. (4) boulons de 9,5 mm (3/8 po) (2) brides de serrage du tuyau Crans de nivellement Figure 1. Cooper Lighting Solutions IB50606822 Instructions d’installation...
  • Page 7 Vissez-les sur l'écrou d'ancrage. Pour les poteaux ronds seulement – installez la plaque Poteau d'adaptation ronde en plaçant le côté rond face au carré poteau (Figure 7). Alignez les trous supérieurs et Figure 6. Cooper Lighting Solutions IB50606822 Instructions d’installation...
  • Page 8: Entretien

    Un nettoyage supplémentaire peut être effectué à l'aide d'un nettoyant en Figure 9. polycarbonate non abrasif. Enlevez la saleté, les feuilles et tout autre débris du boîtier. Cooper Lighting Solutions IB50606822 Instructions d’installation...
  • Page 9 Riesgo de lesiones personales: la luminaria puede dañarse o desestabilizarse de no instalarla correctamente. RENUNCIA DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o pérdidas de ningún tipo que puedan derivarse de la instalación, manipulación o uso incorrecto, descuidado o negligente de este producto.
  • Page 10: Instalación

    16-18 pie-libra ((21,69 a 24,40 N⋅m). Protección contra Pestillo de la pájaros puerta (4) pernos Recorte el brazo de 3/8” de mayor diámetro (2)abrazaderas de tubo Figura 3. Pasos de nivelación Figura 1. Cooper Lighting Solutions IB50606822 Instrucciones de instalación...
  • Page 11 Poste rectangular Inserte las varillas roscadas a través de los orificios superior e inferior. Atornillar en la placa de tuerca. Figura 6. Cooper Lighting Solutions IB50606822 Instrucciones de instalación...
  • Page 12: Mantenimiento

    Se puede realizar una limpieza adicional con el uso de un limpiador no abrasivo al policarbonato. Eliminar la suciedad, hojas u otros residuos extraños de la Figura 9. carcasa. Cooper Lighting Solutions IB50606822 Instrucciones de instalación...
  • Page 13 Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com para conocer nuestros términos y condiciones. Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 Cooper Lighting Solutions is a www.cooperlighting.com registered trademark. All trademarks are property Canada Sales of their respective owners.