LG MULTI V Wide Art Cool Series Installation Manual
LG MULTI V Wide Art Cool Series Installation Manual

LG MULTI V Wide Art Cool Series Installation Manual

Indoor unit

Advertisement

Quick Links

Type: Wide Art Cool Series
IMPORTANT
• Please read this installation manual completely before
installing the product.
• Installation work must be performed in accordance with
the national wiring standards by authorized personnel
only.
• Please retain this installation manual for future reference
after reading it thoroughly.
LG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MULTI V Wide Art Cool Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LG MULTI V Wide Art Cool Series

  • Page 1 Type: Wide Art Cool Series IMPORTANT • Please read this installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. • Please retain this installation manual for future reference after reading it thoroughly.
  • Page 2: Table Of Contents

    Art Cool Type Indoor Unit Installation Manual TABLE OF CONTENTS Required Parts Required Tools Installation Requirements Installation Parts ....3 Safety Precautions ....4 Installation Installation guide map Level gauge Four type "A" screws & plastic Screw driver anchors Electric drill Selection the best location ..9 Connecting cable Hole core drill Horizontal meter...
  • Page 3: Installation Parts

    Installation Parts Installation Parts Air Intake Air Outlet Installation Manual 3...
  • Page 4: Safety Precautions

    Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Be sure to read before installing the air conditioner. Be sure to observe the cautions specified here as they include important items related to safety. Incorrect operation due to ignoring instruction will cause harm or damage.
  • Page 5 Safety Precautions Do not modify or extend the Do not let the air conditioner Be cautious when unpacking power cable. run for a long time when the and installing the product. humidity is very high and a door or a window is left open. •...
  • Page 6 Safety Precautions Installation Always check for gas (refriger- Install the drain hose to ensure Keep level even when installing ant) leakage after installation or that water is drained away prop- the product. repair of product. erly. • Low refrigerant levels may cause •...
  • Page 7: Symbols Used In This Manual

    Introduction Introduction Symbols used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air conditioner. This symbol indicates special notes. NOTICE Features NEO Plasma Filter Air Inlet Front Panel Air Filter...
  • Page 8: Installation

    Installation Installation Read carefully, and then follow step by step. Installation Parts Installation plate Type "A" screw and plastic anchor Remote control holder Type "B" screw Installation Tools Figure Name Figure Name Screw driver Ohmmeter Electric drill Hexagonal wrench Measuring tape, Knife Ammeter Hole core drill Gas-leak detector...
  • Page 9: Selection The Best Location

    Installation Selection of the best location • Do not have any heat or steam near the unit. • Select a place where there are no obstacles in front of the unit. • Make sure that condensation drainage can be conveniently routed away. Do not install near a doorway.
  • Page 10: Preparing Work For Installation

    Installation Preparing Work for Installation Open panel front 1. Push the front panel backward and lift it up to remove the two screws. 2. As soon as you lift the both lower parts of panel front, you can hear the sound from panel front. At this moment panel front is separated 3.
  • Page 11: Fixing Indoor Unit

    Installation Fixing Indoor Unit The wall you select should be strong and solid Installation Plate enough to prevent vibration 1. Mount the installation plate on the wall with type "A" screws. If mounting the unit on a con- crete wall, use anchor bolts. •...
  • Page 12: Flaring Work

    Installation Flaring Work Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the fol- lowing procedure. Cutting the pipes and the cable. 1. Use the piping kit accessory or the pipes pur- chased locally.
  • Page 13: Connecting The Piping

    Installation Check Smooth all round 1. Compare the flared work with the figure by. Inside is shiny without scratches 2. If a flared section is defective, cut it off and do = Improper flaring = flaring work again. Inclined Surface Cracked Uneven damaged thickness...
  • Page 14 Installation 3. Indoor unit installation Hook the indoor unit onto the upper portion of the installation plate.(Engage the two hooks of the rear Connecting top of the indoor unit with the upper edge of the cable installation plate.) Ensure that the hooks are proper- ly seated on the installation plate by moving it left Drain hose and right.
  • Page 15: Drain Piping

    Installation CAUTION: Installation Information For right piping. Follow the instruction below. Good case • Press on the upper side of clamp and unfold the tubing to downward slowly. Bad case • Following bending type from left to right may cause damage to the turbing. Drain Piping 1) To check the drainage.
  • Page 16: Panel Front Assembly

    Installation Panel Front Assembly 1. First, Check the side cover assembly exactly, and fix the power cord in the bot- tom groove of cover side left. 2. Assemble connecting lead wire with con- troller, fix the upper part of panel front, and match the lower part of panel front.
  • Page 17: Wiring Connection

    Installation Wiring Connection • Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in- dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No.
  • Page 18: Installation Of Remote Controller

    Installation Installation of Remote Controller HOW TO MOUNT ONTO A WALL HOW TO INSERT BATTERIES 1. Remove the battery cover from the remote controller. • Do not use rechargeable batteries, • Slide the cover according to the arrow direction. such batteries differ from standard dry cells in shape, dimensions, and per- 2.