Mitsubishi Electric MSZ-LN18VG2W Operating Instructions Manual
Mitsubishi Electric MSZ-LN18VG2W Operating Instructions Manual

Mitsubishi Electric MSZ-LN18VG2W Operating Instructions Manual

Hide thumbs Also See for MSZ-LN18VG2W:

Advertisement

Quick Links

SPLIT-TYPE AIR CONDITIONERS
MSZ-LN18VG2W MSZ-LN25VG2W MSZ-LN35VG2W MSZ-LN50VG2W MSZ-LN60VG2W
MSZ-LN18VG2V MSZ-LN25VG2V MSZ-LN35VG2V MSZ-LN50VG2V MSZ-LN60VG2V
MSZ-LN18VG2R MSZ-LN25VG2R MSZ-LN35VG2R MSZ-LN50VG2R MSZ-LN60VG2R
MSZ-LN18VG2B MSZ-LN25VG2B MSZ-LN35VG2B MSZ-LN50VG2B MSZ-LN60VG2B
INDOOR UNIT
OPERATING INSTRUCTIONS
BEDIENUNGSANLEITUNG
NOTICE D'UTILISATION
BEDIENINGSINSTRUCTIES
MANUAL DE INSTRUCCIONES
LIBRETTO D'ISTRUZIONI
ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ
INSTRUÇÕES DE OPERAÇÃO
BETJENINGSVEJLEDNING
BRUKSANVISNING
РЪКОВОДСТВО ЗА ЕКСПЛОАТАЦИЯ
INSTRUKCJA OBSŁUGI
BRUKSANVISNING
KÄYTTÖOHJEET
NÁVOD K OBSLUZE
NÁVOD NA OBSLUHU
HASZNÁLATI ÚTMUTATÓ
NAVODILA ZA UPORABO
INSTRUCŢIUNI DE UTILIZARE
KASUTUSJUHEND
LIETOŠANAS INSTRUKCIJAS
NAUDOJIMO INSTRUKCIJA
UPUTE ZA UPORABU
UPUTSTVA ZA RUKOVANJE
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Português
Dansk
Svenska
Български
Polski
Norsk
Suomi
Čeština
Slovenčina
Magyar
Slovenščina
Română
Eesti
Latviski
Lietuviškai
Hrvatski
Srpski

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSZ-LN18VG2W and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Electric MSZ-LN18VG2W

  • Page 1 SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSZ-LN18VG2W MSZ-LN25VG2W MSZ-LN35VG2W MSZ-LN50VG2W MSZ-LN60VG2W MSZ-LN18VG2V MSZ-LN25VG2V MSZ-LN35VG2V MSZ-LN50VG2V MSZ-LN60VG2V MSZ-LN18VG2R MSZ-LN25VG2R MSZ-LN35VG2R MSZ-LN50VG2R MSZ-LN60VG2R MSZ-LN18VG2B MSZ-LN25VG2B MSZ-LN35VG2B MSZ-LN50VG2B MSZ-LN60VG2B English OPERATING INSTRUCTIONS Deutsch BEDIENUNGSANLEITUNG Français NOTICE D’UTILISATION Nederlands BEDIENINGSINSTRUCTIES Español MANUAL DE INSTRUCCIONES Italiano LIBRETTO D’ISTRUZIONI...
  • Page 2: Manual Download

    Manual Download http://www.mitsubishielectric.com/ldg/ibim/ EN This manual is brief version. Go to the above website and choose language to download full version OPERATING INSTRUCTIONS and INSTALLATION MANUAL. DE Diese Anleitung ist eine Kurzversion. Besuchen Sie die oben stehende Website und wählen Sie die Sprache aus, um die vollständige Version von BEDIENUNGSANLEITUNG und INSTALLATIONSANLEITUNG herunterzuladen.
  • Page 3: Safety Precautions

    ENGLISH IS ORIGINAL AFETY PRECAUTIONS Meanings of symbols displayed on indoor unit and/or outdoor unit WARNING This unit uses a fl ammable refrigerant. If refrigerant leaks and comes in contact with fi re or heating part, it will create harmful gas and there is risk of fi re. (Risk of fi...
  • Page 4 To use this unit correctly and safely, be sure to read these operating instructions before use. AFETY PRECAUTIONS Do not place other electric appliances or furniture under the indoor/ For installation outdoor unit. • Water may drip down from the unit, which may cause damage or malfunction.
  • Page 5: Outdoor Unit

    ISPOSAL To dispose of this product, consult your dealer. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and Note: accumulators, at their end-of-life, should be disposed of separately from your household waste.
  • Page 6: Remote Controller

    ● OPERATING INSTRUCTIONS ● REPARATION BEFORE OPERATION Remote controller OFF/ON (stop/operate) button Battery replacement indicator Signal transmitting section Distance of signal : Operation select button Operation About 6 m display section Beep(s) is (are) heard from the indoor unit when the (AUTO) (COOL) (DRY)
  • Page 7: Front Panel

    LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Do not soak or rinse the horizontal vane. • Be careful not to touch the metal parts with your hands. • Do not use water hotter than 50°C. •...
  • Page 8 ● OPERATING INSTRUCTIONS ● i-Fi INTERFACE SETTING UP This Wi-Fi interface, communicates the status information and controls the commands from the MELCloud by connecting to the indoor unit. Note: • Set up a connection between the Wi-Fi interface and the Router. Refer to the SETUP MANUAL and SETUP QUICK REFERENCE GUIDE provided with the unit.
  • Page 9: Specifications

    PECIFICATIONS Indoor MSZ-LN18VG2 MSZ-LN25VG2 MSZ-LN35VG2 MSZ-LN50VG2 MSZ-LN60VG2 Model Outdoor MUZ-LN25VG(HZ)2 MUZ-LN35VG(HZ)2 MUZ-LN50VG2 MUZ-LN50VGHZ MUZ-LN60VG Function Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Power supply ~ /N, 230 V, 50 Hz Capacity Input 0.485 0.60 0.82 0.82 1.38 1.48...
  • Page 10 SPLIT-TYPE AIR CONDITIONERS MSZ-LN25VGW MSZ-LN35VGW MSZ-LN50VGW MSZ-LN60VGW INDOOR UNIT MSZ-LN25VGV MSZ-LN35VGV MSZ-LN50VGV MSZ-LN60VGV MSZ-LN25VGR MSZ-LN35VGR MSZ-LN50VGR MSZ-LN60VGR MSZ-LN25VGB MSZ-LN35VGB MSZ-LN50VGB MSZ-LN60VGB For user OPERATING INSTRUCTIONS English is original. English • To use this unit correctly and safely, be sure to read these operating in- structions before use.
  • Page 11 ● OPERATING INSTRUCTIONS ● ONTENTS I SAFETY PRECAUTIONS I DISPOSAL I NAME OF EACH PART I PREPARATION BEFORE OPERATION I I-SEE OPERATION I SELECTING OPERATION MODES I FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT I AIRFLOW CONTROL MODE I ABSENCE DETECTION I I-SAVE OPERATION I ECONO COOL OPERATION I NIGHT MODE OPERATION...
  • Page 12 AFETY PRECAUTIONS The unit should not be installed, relocated, disassembled, altered, Do not charge or disassemble the batteries, and do not throw them or repaired by the user. into a fi re. • An improperly handled air conditioner may cause fi re, electric shock, •...
  • Page 13 It can cause malfunctions. ISPOSAL To dispose of this product, consult your dealer. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and...
  • Page 14 AME OF EACH PART Indoor unit Remote controller Air purifying Battery replacement indicator Signal transmitting Page 5 Air inlet device section Page 15 Front panel Operation dis- Distance of signal : Wi-Fi interface play section About 6 m Page 16 Air fi...
  • Page 15: Installing The Remote Controller Batteries

    ● OPERATING INSTRUCTIONS ● REPARATION BEFORE OPERATION Setting the installation position Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. Be sure to set the remote controller in accordance with the installed position of Installing the remote controller batteries the indoor unit.
  • Page 16 -SEE OPERATION In the i-see control mode, the room temperature is controlled based on the sensible temperature. Press during COOL, DRY, HEAT and AUTO mode to activate the i-see control mode. • Press gently using a thin instrument. • lights. (Operation display section) •...
  • Page 17: Selecting Operation Modes

    ● OPERATING INSTRUCTIONS ● ELECTING OPERATION MODES AUTO mode (Auto change over) The unit selects the operation mode according to the difference between the room temperature and the set temperature. During AUTO mode, the unit changes mode (COOL↔HEAT) when the room temperature is about 2°C away from the set temperature for more than 15 minutes.
  • Page 18 AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction Press to select airfl ow direction. Each press changes airfl ow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most effi cient airfl ow direction. COOL/ DRY/FAN: horizontal position.
  • Page 19 ● OPERATING INSTRUCTIONS ● IRFLOW CONTROL MODE BSENCE DETECTION Airfl ow Control mode offers air conditioning according to a location of This function automatically changes the operation to No occupancy an occupant in a room detected by i-see Sensor. energy-saving mode or No occupancy Auto-OFF mode when nobody is in the room.
  • Page 20: Save Operation

    SAVE OPERATION CONO COOL OPERATION Swing airfl ow (change of airfl ow) makes you feel cooler than station- ary airfl ow. The set temperature and the airfl ow direction are automatically changed by the microprocessor. It is possible to perform cooling operation with A simplifi...
  • Page 21 ● OPERATING INSTRUCTIONS ● IGHT MODE OPERATION IR PURIFYING OPERATION NIGHT mode changes the brightness of the operation indicator, disables In the AIR PURIFYING operation, the indoor unit built-in device reduces the beep sound and limits the noise level of the outdoor unit. airborne fungi, viruses, mold, and allergens.
  • Page 22: Powerful Operation

    OWERFUL OPERATION IMER OPERATION (ON/OFF TIMER) Press during COOL or HEAT mode page 7 Press during operation to set the timer. start POWERFUL operation. (ON timer) : The unit turns ON at the set time. Fan speed : Exclusive speed for POWERFUL mode Horizontal vane : Set position, or downward airflow position during (OFF timer) : The unit turns OFF at the set time.
  • Page 23: Weekly Timer Operation

    ● OPERATING INSTRUCTIONS ● EEKLY TIMER OPERATION • A maximum of 4 ON or OFF timers can be set for individual days of the week. • A maximum of 28 ON or OFF timers can be set for a week. Press , and to set ON/OFF, time, and...
  • Page 24: Operation Lock

    PERATION LOCK MERGENCY OPERATION When the remote controller cannot be used... Emergency operation can be activated by pressing the emergency operation switch (E.O.SW) on the indoor unit. Each time the E.O.SW is pressed, the operation changes in the following order: Operation indicator lamp Emergency COOL Emergency HEAT...
  • Page 25 ● OPERATING INSTRUCTIONS ● LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Do not soak or rinse the horizontal vane. • Be careful not to touch the metal parts with your hands. •...
  • Page 26 (ii) system or product fault; or (iii) loss or damage to any system or product; operation. which is caused by or arises from connection to and/or use of any third party Wi-Fi interface or any third party Wi-Fi service with Mitsubishi Electric equipment. For the latest information regarding MELCloud from Mitsubishi Electric Corporation, please visit www.MELCloud.com.
  • Page 27: When You Think That Trouble Has Occurred

    ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED Symptom Explanation & Check points Even if these items are checked, when the unit does not recover from the Remote controller trouble, stop using the air conditioner and consult your dealer. The display on the remote •...
  • Page 28 HEN YOU THINK THAT TROUBLE HAS OCCURRED In the following cases, stop using the air conditioner and consult your dealer. • When water leaks or drips from the indoor unit. • When the operation indicator lamp blinks. • When the breaker trips frequently. •...
  • Page 29: Electrical Work

    ● OPERATING INSTRUCTIONS ● HEN THE AIR CONDITIONER IS NOT NSTALLATION PLACE AND GOING TO BE USED FOR A LONG TIME ELECTRICAL WORK Installation place Operate by COOL mode with the highest temperature Avoid installing the air conditioner in the following places. set or FAN mode for 3 to 4 hours.
  • Page 30 PECIFICATIONS Set name MSZ-LN25VG(HZ) MSZ-LN35VG(HZ) MSZ-LN50VG(HZ) MSZ-LN60VG Model Indoor MSZ-LN25VG MSZ-LN35VG MSZ-LN50VG MSZ-LN60VG Outdoor MUZ-LN25VG(HZ) MUZ-LN35VG(HZ) MUZ-LN50VG MUZ-LN50VGHZ MUZ-LN60VG Function Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Power supply ~ /N, 230 V, 50 Hz Capacity Input 0.485 0.580 0.820...