Thank you for purchasing the SY-MSU44-18G The SY-MSU44-18G is designed with the professional AV installers in mind. The many extensive features assist in system integration, validation and maintenance. It is still the slimmest HDBaseT extender in the world with tremendous flexibility and extraordinary capabilities.
FEATURES PACKAGE CONTENTS Optional Extras CONNECTORS AND CONTROLS Front Rear USING THIS PRODUCT Control Options Front Panel Control IR Remote Control Navigating the LCD Menu System RS232 Control Input Selection Presets Power Mode Audio Settings EDID Settings HDCP Settings Network Settings Account Control Port Names LCD Commands...
The SY-MSU44-18G is a full 18Gbps 4x4 HDMI matrix switcher with both analogue and digital audio extraction for each output. Each output automatically scaled 4K 2K to ensure an image will be displayed. The matrix has four control methods: Front Panel, RS232, LAN or IR. A front panel locking feature prevents accidental operation.
Direct TCP/IP Control Web Interface Control Front Panel Control The SY-MSU44-18G has four methods for making video selections from the front panel: Select an output button then select an input button to make individual channel selections. Select multiple outputs and then select an input to switch that input to the chosen outputs in one go.
IR Remote Control The IR remote control supplied with the SY-MSU44-18G provides another method for controlling the SY-MSU44-18G. The table below details the function of each button on the IR remote controller. Previous and Next video selections Menu navigation buttons ...
The button below the input group acts as both the Right menu navigation button and the Enter button when making selections in the menu system of the SY-MSU44-18G. F1 to F4 These four buttons have no function.
RS232 Control All RS232 commands are sent to the SY-MS44-18G with the following default settings: 115200 baud, 8 bits, no parity and 1 stop bit. The baud can be changed using the menu system on the LCD or the built-in Web GUI. The other available baud rates are 57600, 19200, and 9600.
Power Mode Use these command to control the power state of the SY-MSU44-18G. Command Response Description SET PWR z PWR z Set the power mode to ON or OFF. GET PWR PWR z Return the current power mode. Set the time in minutes for the SY-...
Page 11
Command Response Description Write EDID Data z to User memory x (1~4) SET EDID U x DATA z EDID U x DATA z z is 256 pairs of hexadecimal ASCII values, for example: 00 FF FF FF … Read the EDID Data from input x (1~4) GET IN y EDID U x DATA EDID U x DATA z...
HDCP Settings These commands control the HDCP mode of the HDMI outputs. Command Response Description Set HDCP on output x to None SET OUT x HDCP CASCADE OUT x HDCP CASCADE (HDCP off) (cascade mode) Set HDCP on output x to 1.4 SET OUT x HDCP 1.4 OUT x HDCP 1.4 only...
Account Control Command Response SET REGISTER <acc> <user> <pwd> REGISTER <acc> <user> Register a new user with account level and password <user> <acc> <pwd> Command Response Description Login a registered user with their SET LOGIN <user> <pwd> LOGIN <user> assigned password Port Names This command sets the name for the specified output.
The actual response SET REBOOT depends on the normal Perform a system reboot start up sequence Direct TCP/IP Control The SY-MSU44-18G is controllable via the IP port using the following default settings: Default IP: 192.168.1.168 Default Gateway: 192.168.1.1 Default Subnet: 255.255.255.0...
Web Interface Control To use the built-in web interface simply connect the SY-MSU44-18G to a network enter its current IP address into a web browser. If the current IP is not known, it can be discovered by either sending the RS232 command GET IP or by navigating the front panel menu system on the LCD.
first select the preset to use and then click on Save or Recall. Only one preset memory can be selected at any instant. Modify Port Name The modify port name displays another panel that allows for renaming of the input, outputs and presets.
Page 17
The Input buttons can be selected individually or collectively to set either a single input or multiple inputs to the desired EDID setting. The Copy buttons will copy the EDID data either from one of the four User memories or from the display device connected to the selected output. The Edit User EDID button opens a separate panel to select which EDID goes to one of the four User EDID memories as the destination.
Network Information This page allows for configuration of the network parameters. Set the DHCP button to off when a static IP address is required. The SY-MSU44-18G also has RS232 commands to control the IP settings – see Network Settings. System Settings sy.uk...
Restore all settings to their factory defaults. RS232 Baud Rate Set the RS232 communication speed. The Change Password panel is used to configure new users and their associated passwords. Click the Apply button to set the changes in the SY-MSU44-18G. Specifications General Inputs...
Damage to the product due to incorrect usage or storage Damage caused by unauthorised repairs Damage caused by mistreatment of the product Please direct any questions or problems you may have to your local dealer before contacting SY Electronics. sy.uk V1.4...
Need help?
Do you have a question about the SY-MSU44-18G and is the answer not in the manual?
Questions and answers