Contents ● Page 3 - Preparing and Switching On ● Page 4 - Walk Test Mode ● Page 5 - Normal Operation ● Page 6 - Registering to a Notifier / Other System Page 7 - Installation ● ● Page 8 - Turning Off and Factory Reset Smart Technology, Made to Care...
The Move will turn on once the battery isolation strip has been removed. The LED will flash red and then green to indicate a good battery, or red again to indicate a low battery. The device will warm-up and after 30 seconds the Move will then enter Walk Test Mode for 2 minutes.
Move Walk Test Mode When the unit is first switched on, after the 30 second warm-up period, it will enter walk test mode for 2 minutes. When in walk test mode, the LED will flash red each time movement is detected, as well as sending a radio message.
Move Normal Operation After the two minute walk test mode has ended, the Move will enter normal operation mode. When in this mode, a radio message will be sent every time movement is detected; the LED will not flash during normal operation. During normal operation, initially movement will be detected immediately, followed by a 30 second detection delay before further detections can occur.
Ensure the Move has been switched on and is in Walk Test Mode. ● ● Prepare the Notifier/other system by entering registration mode. Activate the Move using movement in front of the lens, the LED will flash to confirm. ● ● The Notifier/other system should acknowledge the new device.
Apply pressure to the unit for a few seconds when in position. If the Move is to be screwed to the wall or into a corner, drill through the four screw recesses and use four suitable screws to mount the rear case to the wall, before reassembling the case.
Move Turning Off and Factory Reset Turning off: Remove the batteries or re-insert the isolation strip. Factory reset: Remove and re-insert the batteries. Smart Technology, Made to Care...
Need help?
Do you have a question about the Move and is the answer not in the manual?