Ariterm BeQuem 40 Installation And Operating Instructions Manual

Advertisement

Quick Links

INSTALLATION and OPERATING INSTRUCTIONS
• Ariterm BeQuem 40
ARITERM SERVICE OY
• Asennus ja käyttöohje
- 23.04.2020- 1/24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BeQuem 40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ariterm BeQuem 40

  • Page 1 INSTALLATION and OPERATING INSTRUCTIONS • Ariterm BeQuem 40 ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 1/24...
  • Page 2: Table Of Contents

    General General information and contents of delivery ........2 The new BeQuem 40 pellet burner is an easy to use, reliable and fireproof burner. The Transport, storage and unpacking .............2 advanced automatic function is clear and easy to use. The automatic function detects Technical data ..................3...
  • Page 3: Technical Data

    Maximum motor size for external auger 230 W (1A) 5307 Burner motor 40 W Noise level 58 dB 5886 Chain 77 loops Other Emission class Fuel Pellets Ø = 8 mm (recommendation) 5359 Flame sensor ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 3/24...
  • Page 4: Function Description And Safety

    FUNCTION DESCRIPTION AND SAFETY The BeQuem 40 pellet burner is an easy to use burner. The power is connected to the The burner's automatic function stops the burner in the event of a fault, and a red signal burner and the burner is set up for operation from a menu. The burner checks its status lamp is lit.
  • Page 5: Burner Compatibility With Boiler

    NOTE! A company with professional knowledge should perform the installation of the burner. The installation should be carried out so that it fulfils at a minimum the requirements in standard SFS 3332. ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 5/24...
  • Page 6: Installing Adapter Flange And Slide Mount

    The rails should also be greased so that the Slide mount fastening pin burner slides more easily. Finally, when the burner has been pushed into the boiler, set the burner's quick release. ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 6/24...
  • Page 7: Wiring Diagram

    WIRING DIAGRAM ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 7/24...
  • Page 8: Control Panel

    C button: exit from menus/confir- mation of warning/confirmation of setting value. Enter button: choice of setting/ moving to sub-menu. The factory settings can be reset from the « Dafault settings ». ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 8/24...
  • Page 9: Burner Start, Burner Function

    After a power cut, the burner starts automatically and carries out a warm start or a cold start, depending on the boiler water temperature. ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 9/24...
  • Page 10: Adjustment Of Combustion

    If the draught is not sufficient, a flue gas fan can be installed in the flue pipe, if possible. If Ariterm’s fan controller is used for controlling the flue gas fan, the operating data is received from terminal blocks 13 and 14 of the burner. This is connected to input T6 of the fan controller and - .
  • Page 11: Menu Structure

    Flow water min • Start Low fan 2 • Stop Min fan 2 Temperature Cleaning fan Time Holding time Auger external • Manual Warmstart amount Coldstart amount ABM+40 - v110311 Coldstart settings ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 11/24...
  • Page 12 Regulation, Service. Min xx h Burner operating time at Min power. El 1 Operating time of the 6 kW electrical resistance. El 2 Operating time of the 3 kW electrical resistance ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 12/24...
  • Page 13 To be determined on the basis of experience. Gives an alarm indicating that the boiler and burner head Cleaning x (100) h 0-250 h must be cleaned. To be determined on the basis of experi- ence. ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 13/24...
  • Page 14 (in the example, the load pump stops when the boiler water drops to 69 °C). If the temperature of the boiler water rises to 95 °C, the burner stops instantly. ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 14/24...
  • Page 15: Alarms And Troubleshooting

    Off mode, no alarm resistance heats up and ignites not been enough. is given even if the residual the pellets. oxygen value is displayed on the screen. Only Biomatic+ ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 15/24...
  • Page 16 Service menu. The setting 0 means that the func- possible foreign object from to a foreign object. tion is off. the feeding auger or blocking feeder. ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 16/24...
  • Page 17: Service And Maintenance

    3. Check the wear on the chain and its tension. The chain can be tensioned by moving the burner motor, but do not tension too much. Grease the chain with thin oil. ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 17/24...
  • Page 18: Spare Parts And Accessories

    Ariterm Energy Oy retains the right to decide in which manner the warranty repair should be carried out. Ariterm Energy Oy is not responsible for damage outside the warranty period, but separate agreements can be made in relation to such damage.
  • Page 19: Wood Pellets As Fuel

    Moisture content less than 10% Ash content less than 0.7 weight % Fine material content max 4 weight % > 1,100 °C Ash melting temperature > 4.75 kWh/kg Energy content ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 19/24...
  • Page 20: Installation Report

    Flue gas temperature - Mean Combustion efficiency Draught mm Auger % Blower % Flue gas temperature - Min Combustion efficiency Draught mm Auger % Blower % Dealer / Installer Installer Date ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 20/24...
  • Page 21: Notes

    NOTES ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 21/24...
  • Page 22 NOTES...
  • Page 23 NOTES ARITERM SERVICE OY • Asennus ja käyttöohje - 23.04.2020- 23/24...

This manual is also suitable for:

Bequem 20

Table of Contents