Conroy Qseal-power Operator's Manual

Tube sealer with handle

Advertisement

Quick Links

Operator´s Manual
CS623 Tube Sealer with Handle

Advertisement

loading
Need help?

Need help?

Do you have a question about the Qseal-power and is the answer not in the manual?

Questions and answers

Summary of Contents for Conroy Qseal-power

  • Page 1 Operator´s Manual CS623 Tube Sealer with Handle...
  • Page 2 Every effort has been made to ensure that the information in this document is correct, but we make no guarantee to this effect and would appreciate any observations regard- ing the contents of this document. We may make improvements and alterations to the instrument and these changes will be incorporated in new issues of this publication when practicable.
  • Page 3: Table Of Contents

    Warnings and Cautions ........................... 2 1. Scope ................................4 1.1 Introduction ..........................4 1.2 Performance and specifications ..................4 1.3 Qseal-power parts and spare parts ................11 1.4 Symbols/markings description ..................13 2. Installation .............................15 2.1 Unpacking and inspection ....................15 2.2 Environmental requirements ...................16 2.3 Installation procedure ......................16...
  • Page 4: Warnings And Cautions

    Warning! If any of the components of Qseal-power are exposed to blood, they must be cleaned with an appropriate disinfectant solution. Warning! RF energy during seal procedure and movement of electrode.
  • Page 5 Warning! Qseal-power is not intended for use in an oxygen rich environment. Warning! Qseal-power is not intended to be used with flammable anaesthetics and not intended for use in conjunction with flammable agents. Warning! Do not modify this equipment without authorization of Conroy Medical or Conroy Medical authorized representative.
  • Page 6: Scope

    Sealer with Handle from Conroy Medical AB. 1.1 Introduction Qseal-power is a fully automatic system for sealing PVC tubes, especially for tubes in blood pack systems. Following the sealing procedure the tube is easily pulled apart, due to the distinct sealing pattern, with no damage to the blood inside the tubes.
  • Page 7 Operation: Continuous, max 480 seals per hour. Intended purpose: Intended for sealing tubes and bags in blood component sets. Qseal-power is intended to be used by trained medical professionals. Input Power: 100-240 V ~ 50/60 Hz auto range sense. RF Output: 150 W max.
  • Page 8 Guidance and Manufacturer’s Declaration – Electromagnetic Emission The CS623 Qseal-power Bench Top Sealer is intended for use in the electromagnetic environment specified below. The customer or the user of the CS623 Qseal-power should assure that it is used in such an environment.
  • Page 9 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The CS623 Qseal-power is intended for use in the electromagnetic environment specified be- low. The customer or the user of the Qseal-power should assure that it is used in such an environment. Immunity Test...
  • Page 10 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The CS623 Qseal-power is intended for use in the electromagnetic environment specified below. The customer or the user of the Qseal-power should assure that it is used in such an environment. Immunity Test...
  • Page 11 The CS623 Qseal-power is intended for use in the electromagnetic environment in which radiat- ed RF disturbances are controlled. The customer or the user of the CS623 Qseal-power can help prevent electro-magnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the CS623 Qseal-power as recom- mended below, according to the maximum output power of the communications equipment.
  • Page 12: Front View

    Front view Power switch Connector for the Coaxiable cable Rear view Receptacle for the Power cord CS623 Qseal-power Operator´s manual...
  • Page 13: Qseal-Power Parts And Spare Parts

    1.3 Qseal-power parts and spare parts 1.3.1 Qseal-power, REF CS623 Qseal-power comprises the parts listed below: Description Main Unit Hand Unit Part No. 623000000 62500000 Description Power Cord Coaxial Cable 2.3 m Part No. 879011251 62500100 List of all cables and maximum lengths of cables, transducers and other accessories...
  • Page 14 1.3.2 Qseal-power spare parts (user interchangeable parts) Description Main Unit Hand Unit Part No. 9623000000 962500000 Description Power Cord Coaxial Cable 2.3 m Part No. 879011251 962500100 CS623 Qseal-power Operator´s manual...
  • Page 15: Symbols/Markings Description

    Medical Devices. Symbol for “CATALOGUE NUMBER”. Symbol for “WARNING”. Symbol for “CONSULT USER MANUAL”. Symbol for “CONSULT OPERATOR MANUAL”. Symbol for “SERIAL NUMBER”. Symbol for “DATE OF MANUFACTURE”. Symbol for “MANUFACTURER”. Symbol for “MEDICAL DEVICE”. CS623 Qseal-power Operator´s manual...
  • Page 16 Symbol for “Non-ionizing RADIATION”. Symbol (WEEE 2002/96/EC) - Do not dispose Product as municipal waste. Collect Product separately. Use collection and return systems available to you. Product brought to EU market after August 13 , 2005. CS623 Qseal-power Operator´s manual...
  • Page 17: Installation

    If any parts are missing or if the parts are damaged, report it immediately. 4. Please keep all shipping and packaging materials, as they may be required for later transportation, at least during the warranty time. CS623 Qseal-power Operator´s manual...
  • Page 18: Environmental Requirements

    If the LED does not light up check that the power cord is correctly inserted. 5. Perform a test seal on an empty or water filled tube to ensure proper operation. Caution! Ensure that all cables are connected before turning the power on. CS623 Qseal-power Operator´s manual...
  • Page 19: Functional Description

    3.1 Description of Sealing The indication for use of Qseal-power is a need for seal and separation of tubing or bags in blood component sets during blood and plasma donation or other blood com- ponent preparation.
  • Page 20: Description Of Equipment

    Front view functions of Main unit, with LED and one Connector (see the picture below). ❶ Connector for the special coaxial cable. ❷ Power switch; turns the equipment power on and off. (I=ON/0=OFF) Front of Main unit. ❶ ❷ CS623 Qseal-power Operator´s manual...
  • Page 21: Operating Instructions

    This chapter describes the use of the instrument. Warning! RF energy during seal procedure and movement of electrode. Warning! Qseal-power uses radio frequency (RF) energy to generate heat for sealing. Users should be cautious of potential electrical shocks or hazards while hand- ling this sealer.
  • Page 22: How To Seal Tubes

    If you should make two or more seals, they should not be within 1 cm (½”) of each other, otherwise the resulting pressure in the tube may cause micro- scopic cracks and holes in the seals. CS623 Qseal-power Operator´s manual...
  • Page 23: If The Sealer Doesn´t Start

    Caution! In case of sealer malfunction (intermittent operation, poor seal quality, the sea- ling time seems too long or too short) contact your local Conroy Medical representative for assistance. Caution! Periodically check the pattern of the sealing visually (see picture below).
  • Page 24: Cleaning

    Do not use chemical or abrasive cleaners such as acetone, ammonia or similar. Do not use sharp edged tools for cleaning, which could damage the finish of the units. Caution! Do not allow liquid to flow into the electronic part of the equipment. CS623 Qseal-power Operator´s manual...
  • Page 25: Main Unit

    We recommend some sealing tests before resuming use, ensure that the electrode moves smoothly in the hand unit. Caution! Do not dip the units in liquid, as they are not waterproof. Intruding liquid will cause malfunction, tiny arcs and reduce the lifetime use. CS623 Qseal-power Operator´s manual...
  • Page 26: Troubleshooting

    Check that the tube is not wet. Check that the electrodes are dry. Contact your local C.M. representative. LED is fast Time out. Check the seal pattern. flashing red. Trigger released. Check the seal pattern. CS623 Qseal-power Operator´s manual...
  • Page 27: Head Unit

    6.3 Parts Replacement Coaxial cable replacement 1. Turn off the power switch and disconnect the Coaxial cable from the main unit and hand unit. 2. Replace the coaxial cable with the same type. CS623 Qseal-power Operator´s manual...
  • Page 28: Warranty And Service

    7. Warranty and Service Information on the warranty and the service provided by Conroy Medical is listed below: 7.1 Warranty Conroy Medical guarantees that the equipment shall be free from defects in material and workmanship when delivered to the original purchaser. Conroy Medical´s sole ob- ligation shall be limited to repair or replacement, at Conroy Medical´s option and ex-...
  • Page 29: Service

    A brief written description of the problem should be attached to the instrument when it is returned for service. Conroy Medical will not be responsible for unauthorized returns or for units damaged in shipment due to improper packing.
  • Page 30: Product Disposal

    The information in chapter 6 (Troubleshooting) covers common problems and offers suggested solutions. 7.3 Product Disposal Product Disposal For Qseal-power disposal (and accessories) at the end of the calculated life cycle of 7 years, please ensure the following: • Do not dispose Qseal-power as unsorted municipal waste.
  • Page 31: Eu Declaration Of Conformity

    Regulation (EU) MDR 2017/745 for medical device and Directive 2011/65/EU (RoHS). This declaration is supported by the quality system approval to ISO 13485 issued by Intertek IMNB. This declaration of conformity is issued under the sole responsibility of Conroy Medical AB. Upplands Vaesby, 2024-10-07 Place and date Nicklas Lundman, CEO CS623 Qseal-power Operator´s manual...
  • Page 34 Operator´s Manual CS623 Tube Sealer with Handle conroymedical.com...