Summary of Contents for ITC T-218
Page 1
PUBLIC ADDRESS SYSTEM T-218 PAGING MIC CONSOLE Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
AC outlet and as doing so may result in fire or electric shock. contact your nearest ITC dealer. Make no further attempt to operate the unit in this condition as this Use the unit only with the voltage specified on the may cause fire or electric shock.
Page 4
When removing the power cord, be sure to hold its plug to pull. Contact your ITC dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long Do not block the ventilation slots in the unit's cover.
2. NOMENCLATURE AND FUNCTIONS 2.1 FRONT PANEL 1. UP/DOWN 8. TEN ZONES Up select button/Down select button Ten zones switch button 2. MIC ON/OFF 9. ALL ZONES MIC switch indicator All zones switch indicator . MIC ON/OFF 10.ALL ZONES MIC switch button All zones switch button 4.
NOMENCLATURE AND FUNCTIONS 2.2 REAR PANEL 1. POWER SWITCH 5. LINE IN On top of the opening Power Line Balanced inputs Press the end, power shut down 6. CHIME VOL . AC power input Chime volume control 3. COM 7. MIC VOL Network Communication Interface MIC volume control 4.
3. WIRING DIAGRAM CONNECTIONS The sixteenth paging mic console The second paging mic console The first paging mic console ALARM IN REMOTE IN - + 2 - + 3 - - + 5 - + 6 - + 7 - + 8 - + 9 - + 10 - OPEN...
4. ADDRESS PAGING SELECTOR ADDRESS CODE SETTING Address code Address code Definition Definition drawing drawing The first The ninth from 1~10 from 81~90 1 2 3 4 1 2 3 4 The second The tenth from 11~20 from 91~100 1 2 3 4 1 2 3 4 The third The eleventh...
5.ADDRESS CODE SETTING Address code setting Hold down the " ALL ZONES " do not put, again, as shown below: Loosen the hand, this time through the press "up ", " down " button to address settings, then click " ALL ZONES "...
7. OPERATION Connect all lines, and is set correctly paging device address code area. Boot display the address of the remote paging microphone code, as follows: After 0.3 seconds, showing two figures show the following: Figures show that the control of the current partition. Press the Select button, you can change the current partition control.
Page 12
At the same time, allowing only a remote call station at the same time paging selector to make a call. 10 zone paging selector receives the current call T-218 non-closure of the region data, the data is not clear;...
Need help?