Fuji Electric RSM-9EB Series Operating Manual
Fuji Electric RSM-9EB Series Operating Manual

Fuji Electric RSM-9EB Series Operating Manual

Multi split type room air conditioner (3 rooms, 4 rooms)

Advertisement

Quick Links

OP E R AT ING MA NUA L
O
M
PERATING
ANUAL
ROOM AIR CONDITIONER
MULTI SPLIT TYPE
(3 ROOMS, 4 ROOMS)
COOLIN G M ODE L
Indoor U nit
RSM-9EB
SERIES
Outdoor U nit
ROM-20EA3
COOLIN G M ODE L
Indoor U nit
RSM-12EB
SERIES
Outdoor U nit
ROM-32EA4
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
P/N 9371150017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RSM-9EB Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Fuji Electric RSM-9EB Series

  • Page 1 OP E R AT ING MA NUA L PERATING ANUAL ROOM AIR CONDITIONER MULTI SPLIT TYPE (3 ROOMS, 4 ROOMS) COOLIN G M ODE L Indoor U nit RSM-9EB SERIES Outdoor U nit ROM-20EA3 COOLIN G M ODE L Indoor U nit RSM-12EB SERIES Outdoor U nit...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ........En-1 ADJUSTING THE DIRECTION OF FEATURES AND FUNCTIONS ......En-2 AIR CIRCULATION ..........En-10 NAME OF PARTS ..........En-3 SWING OPERATION ......... En-11 PREPARATION ............ En-5 MANUAL AUTO OPERATION ......En-11 OPERATION ............En-6 CLEANING AND CARE ........En-12 TIMER OPERATION ..........
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS AUTOMATIC OPERATION REMOVABLE INTAKE GRILLE Merely press the START/STOP button, and the unit will be- The indoor unit’s INTAKE GRILLE can be removed for easy gin automatic operation in the Cooling or Dry mode as ap- cleaning and maintenance. propriate, in accordance with the thermostat setting and the actual temperature of the room.
  • Page 4: Name Of Parts

    NAME OF PARTS Fig. 1 Fig. 2 Fig. 3 Fig. 5 Fig. 4 Fig. 6 Fig. 8 To facilitate explanation, the accompanying illustra- tion has been drawn to show all possible indicators; in actual operation, however, the display will only show those indicators appropriate to the current op- eration.
  • Page 5 Fig. 1 Indoor Unit Fig. 6 Remote Control Unit 1 Operating Control Panel (Fig. 2) H SLEEP button 2 POWER Switch I MASTER CONTROL button 3 MANUAL AUTO button J SET TEMP./SET TIME buttons ( K Signal Transmitter 4 Remote Control Signal Receiver L TIMER button 5 Indicator Lamps (Fig.
  • Page 6: Preparation

    PREPARATION CAUTION! Turn on the Power G Take care to prevent infants from accidentally swallowing batteries. Turn on the circuit breaker. G When not using the remote control unit for an extended period, remove the batteries to avoid possible leakage and Set the POWER switch (Fig.
  • Page 7: Operation

    OPERATION To Select Mode Operation Press the START/STOP button (Fig.6 N). The indoor unit’s OPERATION indicator lamp (red) (Fig. 3 6) will light. The air conditioner will start operating. Press the MASTER CONTROL button (Fig.6 I) to se- lect the desired mode. Each time the button is pressed, the mode will change in the following order: AUTO...
  • Page 8 OPERATION About Mode Operation AUTO: G Depending on the room temperature at the time operation begins, the operating mode will be switched automatically as shown in the accompanying table. Also, depending on the operating mode, the room temperature setting will cause the “standard”...
  • Page 9: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 5). To Use the ON timer or OFF timer To Cancel the Timer Press the START/STOP button (Fig. 6 N) Use the TIMER button to select “TIMER (if the unit is already operating, proceed to step 2).
  • Page 10: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP timer To Cancel the Timer: While the air conditioner is operating or stopped, press the Use the TIMER button to select “TIMER SLEEP button (Fig.
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s AIR FLOW DIRECTION button. Hori- zontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.
  • Page 12: Swing Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING LOUVER button (Fig. 6 P). The SWING indicator lamp (orange) (Fig. 3 8) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the airflow both up and down.
  • Page 13: Cleaning And Care

    CLEANING AND CARE G Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cord. CAUTION! G Be sure the intake grille (Fig. 1 9) is installed securely. G When removing and replacing the air filters, be sure not to touch the heat exchanger, as per- sonal injury may result.
  • Page 14: Troubleshooting

    TROUBLESHOOTING In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the WARNING! Power Supply Plug or turn off the circuit breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 15: Operating Tips

    TROUBLESHOOTING Symptom Items to check See Page G Is the Power Supply Plug disconnected from its outlet, or turn off CHECK ONCE Doesn’t operate at all: the circuit breaker? MORE — G Has there been a power failure? G Has a fuse blown out, or a circuit breaker been tripped? G Is the main POWER Switch set to the OFF position? G Is the timer operating? 8 to 9...
  • Page 16: Temperature And Humidity Range

    OPERATING TIPS Temperature and Humidity Range Cooling Mode Dry Mode Outdoor temperature About 18 to 43 °C About 18 to 43 °C Indoor temperature About 18 to 32 °C About 18 to 32 °C Indoor humidity About 80 % or less About 80 % or less If the unit is used for long periods under high- If the unit is used for long periods under high-...
  • Page 17: Specifications

    SPECIFICATIONS MODEL INDOOR UNIT RSM-9EB SERIES OUTDOOR UNIT ROM-20EA3 TYPE COOLING MULTI SPLIT TYPE POWER 220-240 V~50 Hz OPERATING INDOOR UNIT UNIT A1 or UNIT A2 UNIT B A1 + A2 + B COOLING CAPACITY [kW] 2.70-2.80 2.50-2.60 6.05-6.15 POWER INPUT [kW] 1.07-1.13...

This manual is also suitable for:

Rsm-12eb seriesRom-20ea3Rom-32ea4

Table of Contents