HI 96804
Refractometer for Invert Sugar
Measurements
w w w. h a n n a i n s t . c o m
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K&S HANNA instruments HA96804 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hanna Instruments K&S HANNA instruments HA96804

  • Page 1 Instruction Manual HI 96804 Refractometer for Invert Sugar Measurements w w w. h a n n a i n s t . c o m...
  • Page 2: Table Of Contents

    After 3 minutes of non-use HI 96804 Dimensions: 19.2(W) x 10.2(D) x 6.7 (H)cm All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the Mass: 420g copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA.
  • Page 3: Principle Of Operation

    PRINCIPLE OF OPERATION FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION The Invert Sugar determination is made by measuring the refractive index of a solution. Refractive TOP VIEW Index is an optical characteristic of a substance and the number of dissolved particles in it. Refractive Index is defined as the ratio of the speed of light in empty space to the speed of light in the substance.
  • Page 4: Display Elements

    ERROR MESSAGES ERROR MESSAGES ERROR MESSAGES ERROR MESSAGES ERROR MESSAGES DISPLAY ELEMENTS DISPLAY ELEMENTS DISPLAY ELEMENTS DISPLAY ELEMENTS DISPLAY ELEMENTS r c s l a r u l i . e r e l c u r t u r t l l i t r o r l p s...
  • Page 5 CALIBRATION CALIBRATION CALIBRATION CALIBRATION CALIBRATION MEASUREMENT MEASUREMENT MEASUREMENT MEASUREMENT MEASUREMENT Verify the instrument has been calibrated before taking measurements. Calibration should be performed daily, before measurements are made, when the battery has 1. Wipe off prism surface located at the bottom of the sample well. been replaced, or between a long series of measurements.
  • Page 6: Battery Replacement

    If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service Department and then send it with shipment costs prepaid.