Weltem AmeriCool WPH-3000P Owner's Manual

Weltem AmeriCool WPH-3000P Owner's Manual

Portable heat pump
Hide thumbs Also See for AmeriCool WPH-3000P:

Advertisement

Quick Links

Owner's Manual
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and / or property damage! Retain instructions for future reference.
Portable Heat Pump
Description
AmeriCool Portable Heat Pump feature spot cooling/heating
for large areas where cooling/heating of the entire area is
not practical. A dedicated spot cooling/heating thermostat
controls the unit in this application.
This unit can also be used in smaller areas for room cooling/
heating. A control panel provides ease of use and contains
a self-diagnostic function and display, showing operating
modes, room and set temperatures, and faults.
If an abnormal operation occurs, a visual display of the fault
is shown. Caster wheels are included for easy portability.
Suitable applications include: a factory or work place, indus-
trial kitchen, computer room, emergency cooling/heating,
supplement cooling / heating etc.
Unpacking
After unpacking the unit, carefully inspect unit for any damage that may have occurred during
transit. Check for any loose, missing, or damaged parts.
Specifications
Model No.
Power Supply Ph-V-Hz
Single Phase,
WPH-3000P
Power Cord Gauge
Model No.
WPH-3000P
Cooling Capacity
13,200(Cooling)
115V, 60Hz
14,300(Heating)
Power Cord
AWG
12
Power Consump-
Btu/h
tion Watts
1.08kW(Cooling)
1.01kW(Heatling)
Length ft
6
1
Owner's Manual
WPH-3000P
WPH-3000P
Figure 1
Rated Current
Amps
9.79 A (Cooling)
9.3 A(Heatling)
Dimensions
W x D x H - in. (mm)
20.6x 26.9 x 41.1
(523x 685 x 1044)
EER Btu/
Wh
11.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AmeriCool WPH-3000P and is the answer not in the manual?

Questions and answers

Summary of Contents for Weltem AmeriCool WPH-3000P

  • Page 1 Owner’s Manual Owner’s Manual WPH-3000P Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and / or property damage! Retain instructions for future reference. Portable Heat Pump Description AmeriCool Portable Heat Pump feature spot cooling/heating...
  • Page 2 Optional drain pump kit, Washable filters, °F( °C) display, Off-timer, Auto fan speed option. Thank you for selecting this AMERICOOL by Weltem Portable Heat pump. It provides you with spot cooling/heating for large areas where cooling/heating of an entire area is not practical or possible. Please read this manual before installing...
  • Page 3: General Safety Information

    WPH-3000P Owner’s Manual General Safety Information Please read this manual carefully for instructions on correct installation and usage. Please read all safeguards. 1. Transport and store the unit in an upright position only. Leave unit in an upright position for at least 3 hours before first use.
  • Page 4 WPH-3000P Owner’s Manual DO NOT operate a unit with a damaged power cord. 19. The filters must be used with the product at all times. When the filters are removed for clean- ing, always ensure that the unit has been turned off and unplugged from the electrical outlet. 20.
  • Page 5 WPH-3000P Owner’s Manual Assembly (WPH-3000P) Component parts Top fan exhaust flange Display / Control board Evaporator / filter Guide bar for condensate water tank Condensate water tank (Water level is sensed, and the unit opera�on is stopped when tank is full. An alarm will be displayed. Empty the tank and replace to resume opera�on) Figure 2 Front and Right Side View...
  • Page 6: Installation

    WPH-3000P Owner’s Manual Installation WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or in areas where flammable gas leakage may occur. Do not use the unit in areas where it will be exposed to rain or water. Do not use the unit in a corrosive atmosphere.
  • Page 7: Operation

    WPH-3000P Owner’s Manual Operation CONTROL PANEL CURRENT TARGET TEMP TEMP ALARM DOWN COOL BLOWER POWER HEAT Figure 6 (2) ICEN WPH-3000P Detail / Setting Press the “Power” button to turn on the unit. Press the “Power” button for 2 seconds to turn off the unit. <Note : It takes more than 3 minutes to start fan>...
  • Page 8 WPH-3000P Owner’s Manual · Press the “Cool” button to set the IN Temperature. · Non setting temperature is 18°C. You can set the temperature from 18°C to 30°C (from 0°F to 30°F) · Press “UP/DOWN” Button to set the temperature. ·...
  • Page 9 WPH-3000P Owner’s Manual · Enter to timer setting mode by pressing Cool BUTTON and Blower BUTTON together for 2 seconds. · Press UP/DOWN BUTTON to set the timer until it shows the figure you want to set. (Setting range is between 30 minutes and 12 hours.) ·...
  • Page 10: Monitor Mode

    WPH-3000P Owner’s Manual · You can check the value of operating sensors with display. 1) Press the “Blower” and “Heat” button together to check the value of the sensors. BLOWER HEAT 2) You can see the data by using “UP/DOWN” button. DOWN 3) “Current”...
  • Page 11: Maintenance

    WPH-3000P Owner’s Manual Maintenance FILTER CLEANING (See Figures 7 and 8) There are two filters in the unit. The evaporator filter is located at the front of the unit. The condenser filter is located at the back of the unit. 1.
  • Page 12: Spring Replacement

    WPH-3000P Owner’s Manual Maintenance (Continued) – To ensure your product is covered by warranty, the complete faulty product along with your original purchase receipt must be provided at the place of purchase. Product Portable Air Conditioner Customer: Please read and keep this Model No.
  • Page 13 The alarm light is activated if abnormal operation occurs, and a code is displayed on the control panel. WPH-3000P Owner’s Manual The alarm light is activated if abnormal operation occurs, and a code is displayed on the control panel. The compressor and condenser fan motor will stop operating. The evaporator fan will continue to run for The compressor and condenser fan motor will stop operating.
  • Page 14 temperature Contact a qualified service agent loose or broken connection sensor value Abnormal The alarm light is activated if abnormal operation occurs, and a code is displayed on the control panel. Outlet temperature sensor has a The compressor and condenser fan motor will stop operating. The evaporator fan will continue to run for temperature Contact a qualified service agent loose or broken connection...
  • Page 15: Wiring Diagram

    000P WPH-3000P Owner’s Manual Wiring Diagram WPH-3000P (H2.1) DRAIN PUMP LOW PRESS (Option) FLOAT SWITCH SENSOR CURRENT TARGET TEMP TEMP DATA CABLE (RJ45) ALARM DOWN COOL BLOWER +V S G E. FAN C. FAN COMP LOW PRESS HIGH PRESS SENSOR POWER HEAT IN_TEMP...
  • Page 16: Troubleshooting Chart

    WPH-3000P Owner’s Manual Troubleshooting chart Symptom Possible Cause(s) Corrective Action High water level in con- 1. Remove blockage from drain densate tank hose Water leakage 2. Remove any object stuck under- neath of the black panel under the water tank 1.
  • Page 17: Shipping List

    • (1) POWER CORD HOLDER • (2) DISCHARGE / SUPPLY AIR DUCTS • (1) EXHAUST FLANGE OBTAINING SERVICE AmeriCool by Weltem Portable Air Conditioner If the requires Service: 1. Use the TROUBLESHOOTING section in this manual to eliminate obvious causes.
  • Page 18: Limited Warranty

    TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY, AS LIMITED HEREIN, SHALL BE IN LIEU OF AND EXCLUSIVE OF ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, ON THE PART OF AMERICOOL INC., OR WELTEM CO.,LTD. WHETHER ARISING FROM LAW, COURSE OF DEALING, US- AGE OF TRADE, OR OTHERWISE, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANT-ABILITY OR FITNESS OF A PARTICULAR PURP OSE OR ANY LIABILITY FOR COMMERCIAL LOSSES BASED UPON NEGLIGENCE OR MANUFACTURER’S STRICT LIABILITY.

This manual is also suitable for:

Americool wph-3000

Table of Contents