Page 1
Operating Instructions P1XD212 Fiber-optic amplifier Translation of the original operating instructions Subject to change without notice Available as PDF file only Version 2.0...
The safety precautions and warnings are laid out in accordance with the following principle: SIGNAL WORD Type and source of danger! Possible consequences in the event that the hazard is disregarded. à Measures for averting the hazard. 1 ‒ General | P1XD212 ‒ Fiber-optic amplifier...
• wenglor assumes no liability for printing errors or other inaccuracies contained in these operating in- structions unless wenglor was verifiably aware of such errors at the point in time at which the operat- ing instructions were prepared.
• All rights are reserved by wenglor. • Commercial reproduction or any other commercial use of the provided content and information, in particular graphics and images, is not permitted without previous written consent from wenglor. 1 ‒ General | P1XD212 ‒ Fiber-optic amplifier...
• The product is not suitable for use in potentially explosive atmospheres. • The product may be used only with accessories supplied or approved by wenglor, or in combination with approved products. A list of approved accessories and combination products can be found at www.wenglor.com on the product detail page.
Read the operating instructions carefully before using the product. Protect the sensor against contamination and mechanical influences. Approvals and Protection Class IND. CONT. EQ 72HL / E189727 For use in class 2 circuits 2 ‒ For Your Safety | P1XD212 ‒ Fiber-optic amplifier...
21 = mode button Complementary Products wenglor offers you the right connection and mounting technology as well as other accessories for your product. You can find this at www.wenglor.com on the product details page at the bottom. Scope of Delivery •...
• Protect the product against exposure to direct sunlight. NOTICE Risk of property damage in case of improper storage! The product may be damaged. à Storage instructions must be complied with. 4 ‒ Transport and Storage | P1XD212 ‒ Fiber-optic amplifier...
Mounting on a DIN Rail Mounting on a DIN rail is tool-free. Hook the sensor onto the DIN rail and push the sensor down until it clicks into place through the integrated spring. 5 ‒ Installation and Electrical Connection | P1XD212 ‒ Fiber-optic amplifier...
This allows you to release the sensor up- wards. 5.1.3 Mounting Multiple Sensors on a DIN Rail • Remove the side cover cap with a screwdriver. 5 ‒ Installation and Electrical Connection | P1XD212 ‒ Fiber-optic amplifier...
Page 15
• Remove the side cover cap(s) on the next sensor and plug in another side connector if necessary. • Attach the sensor to the DIN rail and plug it into the side connector of the master sensor. 5 ‒ Installation and Electrical Connection | P1XD212 ‒ Fiber-optic amplifier...
Page 16
„CLICK“ • Up to 14 sensors can be connected in this way. 5 ‒ Installation and Electrical Connection | P1XD212 ‒ Fiber-optic amplifier...
• Fasten the Z1XZ001 adapter with the enclosed mounting set through the mounting holes in the de- sired position. • Snap the sensor onto the adapter as described in Mounting on a DIN Rail. 5 ‒ Installation and Electrical Connection | P1XD212 ‒ Fiber-optic amplifier...
• Insert the fiber-optic cable into the openings provided as far as it will go. NOTICE Depending on the fiber-optic cable used, it may be necessary to check how the emitter/receiver is as- signed. 5 ‒ Installation and Electrical Connection | P1XD212 ‒ Fiber-optic amplifier...
Risk of personal injury or property damage due to electric current. Voltage-conducting parts may cause personal injury or damage to equipment. à The electric device may be connected by appropriately qualified personnel only. 5 ‒ Installation and Electrical Connection | P1XD212 ‒ Fiber-optic amplifier...
Temperature too high: • Mount the mounting bracket as a heat sink • Reduce load on outputs Error Short circuit • Check the electrical wiring and eliminate the short circuit 5 ‒ Installation and Electrical Connection | P1XD212 ‒ Fiber-optic amplifier...
Page 21
1. Shut down the machine. 2. Analyze and eliminate the cause of error with the aid of the diagnostics information. 3. If the error cannot be eliminated, please contact wenglor’s support department. 4. Do not operate in case of indeterminate malfunctioning.
2. Press and hold the Mode button for 2 seconds until the NO/NC indicator starts to flash. 3. Pressing the Mode button again briefly changes the display from NO to NC or vice versa. 4. After 5 seconds, the selected setting is applied to the selected switching output. 6 ‒ Settings | P1XD212 ‒ Fiber-optic amplifier...
1. Press and hold the Mode button for 5 seconds until the Power LED P starts to flash in the currently set color. 2. Press the Mode button again to choose between the colors pink, red and blue. 3. After approx. 5 seconds, the selected transmission light color is adopted. 6 ‒ Settings | P1XD212 ‒ Fiber-optic amplifier...
The maximum switching frequency can be reached only with minimum filter selection Minimum Medium Maximum Hysteresis The hysteresis is the difference between the switch-on and Minimum switch-off point and can be set in 3 stages. 7 ‒ Function Description | P1XD212 ‒ Fiber-optic amplifier...
An activated input corresponds to a depressed Teach-in key. Locking If 18…30 V DC is continuously applied to the teach-in input, the teach-in key is locked and protected against inadvertent changes, like the input signal. Deactivated 7 ‒ Function Description | P1XD212 ‒ Fiber-optic amplifier...
The switching point functions are used to set the two switching points, SSC1 and SSC2. SSC1 is assigned to output A1 and SSC2 is assigned to output A2. Function Possible settings Default Teach-in Starts the teach-in process. Teach-in mode Normal Teach-In 7 ‒ Function Description | P1XD212 ‒ Fiber-optic amplifier...
Page 27
Minimum Teach-In Sensor Teach-in distance Switching point Object Dynamic Readjustment Continuous readjustment of the switching threshold of the sen- sor. The time interval for readjustment can be set on the inter- face. 7 ‒ Function Description | P1XD212 ‒ Fiber-optic amplifier...
Page 28
A jump is detected when the measured value jumps to a higher value, i.e. the contrast value becomes higher. Negative A jump is detected when the measured value jumps to a lower value, i.e. the contrast value becomes lower. 7 ‒ Function Description | P1XD212 ‒ Fiber-optic amplifier...
Temperature error Temperature is outside permissible range. To protect the emitting unit, the laser is switched off. Device error A hardware error has occurred. For safety reasons, the laser is switched off. 7 ‒ Function Description | P1XD212 ‒ Fiber-optic amplifier...
SSC2 Test According to the measured value According to mea- sured value Status messages test Tests the individual status messages According to measured value according to the measured value 7 ‒ Function Description | P1XD212 ‒ Fiber-optic amplifier...
To this end, the sensor is connected to a suitable IO-Link master (see product detail page/complementary products). The interface protocol and the IODD can be found at www.wenglor.com in the download area for the respective product. 8 ‒ IO-Link | P1XD212 ‒ Fiber-optic amplifier...
“weCon” app. Process data cannot be read out via NFC but are available via IO-Link. You can download the wenglor app free of charge from the Google Play Store or the App Store. Down- load the app and follow the installation instructions.
For information on installing and connecting the wTeach2 software and its structure, as well as information on the general functions, see the wTeach2 operating instructions. They can be found online in the down- load area at www.wenglor.com under order number DNNF005. 10 ‒ wTeach2 Configuration Software | P1XD212 ‒ Fiber-optic amplifier...
Cleaning and inspection of the plug connections at regular intervals are advisable. Do not clean the product with solvents or cleaning agents that could damage the product. The product must be protected against contamination during initial start-up. 11 ‒ Maintenance Instructions | P1XD212 ‒ Fiber-optic amplifier...
Proper Disposal wenglor sensoric GmbH does not accept the return of unusable or irreparable products. Respectively valid national waste disposal regulations apply to product disposal. 12 ‒ Proper Disposal | P1XD212 ‒ Fiber-optic amplifier...
Declarations of Conformity Declarations of conformity can be found on our website at www.wenglor.com in the product’s separate download area. 13 ‒ Declarations of Conformity | P1XD212 ‒ Fiber-optic amplifier...
Need help?
Do you have a question about the P1XD212 and is the answer not in the manual?
Questions and answers